ABAP Select data from SAP table YHITEC_CAS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP YHITEC_CAS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to YHITEC_CAS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the YHITEC_CAS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_YHITEC_CAS TYPE STANDARD TABLE OF YHITEC_CAS,
      WA_YHITEC_CAS TYPE YHITEC_CAS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <YHITEC_CAS> TYPE YHITEC_CAS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_YHITEC_CAS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM YHITEC_CAS
  INTO TABLE IT_YHITEC_CAS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM YHITEC_CAS
*  INTO TABLE @DATA(IT_YHITEC_CAS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_YHITEC_CAS INDEX 1 INTO DATA(WA_YHITEC_CAS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_YHITEC_CAS ASSIGNING <YHITEC_CAS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<YHITEC_CAS>-MANDT = 1.
<YHITEC_CAS>-IMPORT_YEAR = 1.
<YHITEC_CAS>-CASE_ID = 1.
<YHITEC_CAS>-CASE_VERS = 1.
<YHITEC_CAS>-CLC_DATE = 1.
ENDLOOP.

LOOP AT IT_YHITEC_CAS INTO WA_YHITEC_CAS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_YHITEC_CAS-CLC_TIME, sy-vline,
WA_YHITEC_CAS-KNW_DATE, sy-vline,
WA_YHITEC_CAS-KNW_TIME, sy-vline,
WA_YHITEC_CAS-POST_DATE, sy-vline,
WA_YHITEC_CAS-RESP_DATE, sy-vline,
WA_YHITEC_CAS-IMPORT_DATE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_YHITEC_CAS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_YHITEC_CAS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_YHITEC_CAS INTO WA_YHITEC_CAS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field CASE_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_YHITEC_CAS-CASE_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_YHITEC_CAS-CASE_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit BOBJ0, internal->external for field BUSOBJ_TYPE CALL FUNCTION 'CONVERSION_EXIT_BOBJ0_OUTPUT' EXPORTING input = WA_YHITEC_CAS-BUSOBJ_TYPE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_YHITEC_CAS-BUSOBJ_TYPE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit BOBJ1, internal->external for field BUSOBJ_ID CALL FUNCTION 'CONVERSION_EXIT_BOBJ1_OUTPUT' EXPORTING input = WA_YHITEC_CAS-BUSOBJ_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_YHITEC_CAS-BUSOBJ_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field BUSOBJ_VERSDATE CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_YHITEC_CAS-BUSOBJ_VERSDATE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_YHITEC_CAS-BUSOBJ_VERSDATE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field REM_BUSCASE_TYP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_YHITEC_CAS-REM_BUSCASE_TYP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_YHITEC_CAS-REM_BUSCASE_TYP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field REM_BUSCASE_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_YHITEC_CAS-REM_BUSCASE_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_YHITEC_CAS-REM_BUSCASE_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TRIGGER_SYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_YHITEC_CAS-TRIGGER_SYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_YHITEC_CAS-TRIGGER_SYS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TRI_BUSCASE_TYP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_YHITEC_CAS-TRI_BUSCASE_TYP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_YHITEC_CAS-TRI_BUSCASE_TYP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TRI_BUSCASE_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_YHITEC_CAS-TRI_BUSCASE_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_YHITEC_CAS-TRI_BUSCASE_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RUN_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_YHITEC_CAS-RUN_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_YHITEC_CAS-RUN_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EXT_RUN_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_YHITEC_CAS-EXT_RUN_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_YHITEC_CAS-EXT_RUN_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit BOBJ0, internal->external for field COPY_OBJ_TYPE CALL FUNCTION 'CONVERSION_EXIT_BOBJ0_OUTPUT' EXPORTING input = WA_YHITEC_CAS-COPY_OBJ_TYPE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_YHITEC_CAS-COPY_OBJ_TYPE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit BOBJ1, internal->external for field COPY_OBJ_ID CALL FUNCTION 'CONVERSION_EXIT_BOBJ1_OUTPUT' EXPORTING input = WA_YHITEC_CAS-COPY_OBJ_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_YHITEC_CAS-COPY_OBJ_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field COPY_CASE_TYPE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_YHITEC_CAS-COPY_CASE_TYPE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_YHITEC_CAS-COPY_CASE_TYPE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field COPY_CASE_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_YHITEC_CAS-COPY_CASE_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_YHITEC_CAS-COPY_CASE_ID.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_YHITEC_CAS_STR,
MANDT TYPE STRING,
IMPORT_YEAR TYPE STRING,
CASE_ID TYPE STRING,
CASE_VERS TYPE STRING,
CLC_DATE TYPE STRING,
CLC_TIME TYPE STRING,
KNW_DATE TYPE STRING,
KNW_TIME TYPE STRING,
POST_DATE TYPE STRING,
RESP_DATE TYPE STRING,
IMPORT_DATE TYPE STRING,
RELEASE_DATE TYPE STRING,
FLG_NOSETTLEMENT TYPE STRING,
FLG_NORESETTLE TYPE STRING,
FLG_FUTURECHECK TYPE STRING,
BUSOBJ_TYPE TYPE STRING,
BUSOBJ_ID TYPE STRING,
BUSOBJ_VERS TYPE STRING,
BUSOBJ_VERSDATE TYPE STRING,
REM_BUSCASE_TYP TYPE STRING,
REM_BUSCASE_ID TYPE STRING,
REM_BUSCASE_VERS TYPE STRING,
LED_CURR TYPE STRING,
CASE_TXT TYPE STRING,
TRIGGER_SYS TYPE STRING,
TRIGGER_DATE TYPE STRING,
TRI_BUSCASE_TYP TYPE STRING,
TRI_BUSCASE_ID TYPE STRING,
TRI_BUSCASE_VERS TYPE STRING,
TRGCAS_TYPE TYPE STRING,
TRGCASAGR_ID TYPE STRING,
TRGCASRU_ID TYPE STRING,
PERIODRULE_ID TYPE STRING,
PERIOD_NO TYPE STRING,
RUN_ID TYPE STRING,
EXT_RUN_ID TYPE STRING,
COPY_OBJ_TYPE TYPE STRING,
COPY_OBJ_ID TYPE STRING,
COPY_OBJ_VERS TYPE STRING,
COPY_CASE_TYPE TYPE STRING,
COPY_CASE_ID TYPE STRING,
FLG_COPY_PAR TYPE STRING,
FLG_COPY_ACT TYPE STRING,
FLG_COPY_OBJ TYPE STRING,
FLG_CANCEL_OBJ TYPE STRING,
FLG_CANCEL_VERS TYPE STRING,
CHG_DATE TYPE STRING,
CHG_TIME TYPE STRING,
CHG_TCODE TYPE STRING,
CHG_USR TYPE STRING,
TRI_METH_TYP TYPE STRING,
TRI_METH_TARGET TYPE STRING,
STATUS_VERSION TYPE STRING,
STATUS_WORK TYPE STRING,
REV_DATE TYPE STRING,
REV_TIME TYPE STRING,
REV_TCODE TYPE STRING,
REV_USR TYPE STRING,
LOG_HANDLE TYPE STRING,END OF T_EKKO_STR. DATA: WA_YHITEC_CAS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_YHITEC_CAS_STR-MANDT sy-vline
WA_YHITEC_CAS_STR-IMPORT_YEAR sy-vline
WA_YHITEC_CAS_STR-CASE_ID sy-vline
WA_YHITEC_CAS_STR-CASE_VERS sy-vline
WA_YHITEC_CAS_STR-CLC_DATE sy-vline
WA_YHITEC_CAS_STR-CLC_TIME sy-vline
WA_YHITEC_CAS_STR-KNW_DATE sy-vline
WA_YHITEC_CAS_STR-KNW_TIME sy-vline
WA_YHITEC_CAS_STR-POST_DATE sy-vline
WA_YHITEC_CAS_STR-RESP_DATE sy-vline
WA_YHITEC_CAS_STR-IMPORT_DATE sy-vline
WA_YHITEC_CAS_STR-RELEASE_DATE sy-vline
WA_YHITEC_CAS_STR-FLG_NOSETTLEMENT sy-vline
WA_YHITEC_CAS_STR-FLG_NORESETTLE sy-vline
WA_YHITEC_CAS_STR-FLG_FUTURECHECK sy-vline
WA_YHITEC_CAS_STR-BUSOBJ_TYPE sy-vline
WA_YHITEC_CAS_STR-BUSOBJ_ID sy-vline
WA_YHITEC_CAS_STR-BUSOBJ_VERS sy-vline
WA_YHITEC_CAS_STR-BUSOBJ_VERSDATE sy-vline
WA_YHITEC_CAS_STR-REM_BUSCASE_TYP sy-vline
WA_YHITEC_CAS_STR-REM_BUSCASE_ID sy-vline
WA_YHITEC_CAS_STR-REM_BUSCASE_VERS sy-vline
WA_YHITEC_CAS_STR-LED_CURR sy-vline
WA_YHITEC_CAS_STR-CASE_TXT sy-vline
WA_YHITEC_CAS_STR-TRIGGER_SYS sy-vline
WA_YHITEC_CAS_STR-TRIGGER_DATE sy-vline
WA_YHITEC_CAS_STR-TRI_BUSCASE_TYP sy-vline
WA_YHITEC_CAS_STR-TRI_BUSCASE_ID sy-vline
WA_YHITEC_CAS_STR-TRI_BUSCASE_VERS sy-vline
WA_YHITEC_CAS_STR-TRGCAS_TYPE sy-vline
WA_YHITEC_CAS_STR-TRGCASAGR_ID sy-vline
WA_YHITEC_CAS_STR-TRGCASRU_ID sy-vline
WA_YHITEC_CAS_STR-PERIODRULE_ID sy-vline
WA_YHITEC_CAS_STR-PERIOD_NO sy-vline
WA_YHITEC_CAS_STR-RUN_ID sy-vline
WA_YHITEC_CAS_STR-EXT_RUN_ID sy-vline
WA_YHITEC_CAS_STR-COPY_OBJ_TYPE sy-vline
WA_YHITEC_CAS_STR-COPY_OBJ_ID sy-vline
WA_YHITEC_CAS_STR-COPY_OBJ_VERS sy-vline
WA_YHITEC_CAS_STR-COPY_CASE_TYPE sy-vline
WA_YHITEC_CAS_STR-COPY_CASE_ID sy-vline
WA_YHITEC_CAS_STR-FLG_COPY_PAR sy-vline
WA_YHITEC_CAS_STR-FLG_COPY_ACT sy-vline
WA_YHITEC_CAS_STR-FLG_COPY_OBJ sy-vline
WA_YHITEC_CAS_STR-FLG_CANCEL_OBJ sy-vline
WA_YHITEC_CAS_STR-FLG_CANCEL_VERS sy-vline
WA_YHITEC_CAS_STR-CHG_DATE sy-vline
WA_YHITEC_CAS_STR-CHG_TIME sy-vline
WA_YHITEC_CAS_STR-CHG_TCODE sy-vline
WA_YHITEC_CAS_STR-CHG_USR sy-vline
WA_YHITEC_CAS_STR-TRI_METH_TYP sy-vline
WA_YHITEC_CAS_STR-TRI_METH_TARGET sy-vline
WA_YHITEC_CAS_STR-STATUS_VERSION sy-vline
WA_YHITEC_CAS_STR-STATUS_WORK sy-vline
WA_YHITEC_CAS_STR-REV_DATE sy-vline
WA_YHITEC_CAS_STR-REV_TIME sy-vline
WA_YHITEC_CAS_STR-REV_TCODE sy-vline
WA_YHITEC_CAS_STR-REV_USR sy-vline
WA_YHITEC_CAS_STR-LOG_HANDLE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.