ABAP Select data from SAP table WVZBAVF into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP WVZBAVF table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to WVZBAVF. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the WVZBAVF table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_WVZBAVF TYPE STANDARD TABLE OF WVZBAVF,
      WA_WVZBAVF TYPE WVZBAVF,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <WVZBAVF> TYPE WVZBAVF.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_WVZBAVF.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM WVZBAVF
  INTO TABLE IT_WVZBAVF.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM WVZBAVF
*  INTO TABLE @DATA(IT_WVZBAVF2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_WVZBAVF INDEX 1 INTO DATA(WA_WVZBAVF2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_WVZBAVF ASSIGNING <WVZBAVF>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<WVZBAVF>-MANDT = 1.
<WVZBAVF>-RANTYP = 1.
<WVZBAVF>-VVKEY = 1.
<WVZBAVF>-JDECK = 1.
<WVZBAVF>-JBAVG = 1.
ENDLOOP.

LOOP AT IT_WVZBAVF INTO WA_WVZBAVF.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_WVZBAVF-XAKTZBAV, sy-vline,
WA_WVZBAVF-DBAVGEN, sy-vline,
WA_WVZBAVF-SGBAV, sy-vline,
WA_WVZBAVF-SBAV501, sy-vline,
WA_WVZBAVF-SBILK, sy-vline,
WA_WVZBAVF-JARW, sy-vline.
ENDLOOP. *Add any further fields from structure WA_WVZBAVF you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_WVZBAVF TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_WVZBAVF INTO WA_WVZBAVF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field VVKEY CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WVZBAVF-VVKEY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WVZBAVF-VVKEY.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_WVZBAVF_STR,
MANDT TYPE STRING,
RANTYP TYPE STRING,
VVKEY TYPE STRING,
JDECK TYPE STRING,
JBAVG TYPE STRING,
XAKTZBAV TYPE STRING,
DBAVGEN TYPE STRING,
SGBAV TYPE STRING,
SBAV501 TYPE STRING,
SBILK TYPE STRING,
JARW TYPE STRING,
DARWGEN TYPE STRING,
XAKTZARW TYPE STRING,
XAUFORT TYPE STRING,
BARWBAV TYPE STRING,
SAWHR TYPE STRING,
DERWMEL TYPE STRING,
BVWERT TYPE STRING,
SVWHR TYPE STRING,
BARW_VU TYPE STRING,
SAWHR_VU TYPE STRING,
SNW101 TYPE STRING,
SNW102 TYPE STRING,
SNW201 TYPE STRING,
SJBUE TYPE STRING,
SNEU_ANL TYPE STRING,
XR5_91_1 TYPE STRING,
XR5_91_2 TYPE STRING,
XR5_91_3 TYPE STRING,
XTREU TYPE STRING,
XDECK TYPE STRING,
XARW TYPE STRING,
SMW102 TYPE STRING,
X_R97_03 TYPE STRING,
X_R97_05 TYPE STRING,
X_R97_06 TYPE STRING,
X_R97_08 TYPE STRING,
X_R97_101 TYPE STRING,
X_R97_102 TYPE STRING,
X_R97_103 TYPE STRING,
X_R97_104 TYPE STRING,
XTREU1 TYPE STRING,
KZ TYPE STRING,END OF T_EKKO_STR. DATA: WA_WVZBAVF_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_WVZBAVF_STR-MANDT sy-vline
WA_WVZBAVF_STR-RANTYP sy-vline
WA_WVZBAVF_STR-VVKEY sy-vline
WA_WVZBAVF_STR-JDECK sy-vline
WA_WVZBAVF_STR-JBAVG sy-vline
WA_WVZBAVF_STR-XAKTZBAV sy-vline
WA_WVZBAVF_STR-DBAVGEN sy-vline
WA_WVZBAVF_STR-SGBAV sy-vline
WA_WVZBAVF_STR-SBAV501 sy-vline
WA_WVZBAVF_STR-SBILK sy-vline
WA_WVZBAVF_STR-JARW sy-vline
WA_WVZBAVF_STR-DARWGEN sy-vline
WA_WVZBAVF_STR-XAKTZARW sy-vline
WA_WVZBAVF_STR-XAUFORT sy-vline
WA_WVZBAVF_STR-BARWBAV sy-vline
WA_WVZBAVF_STR-SAWHR sy-vline
WA_WVZBAVF_STR-DERWMEL sy-vline
WA_WVZBAVF_STR-BVWERT sy-vline
WA_WVZBAVF_STR-SVWHR sy-vline
WA_WVZBAVF_STR-BARW_VU sy-vline
WA_WVZBAVF_STR-SAWHR_VU sy-vline
WA_WVZBAVF_STR-SNW101 sy-vline
WA_WVZBAVF_STR-SNW102 sy-vline
WA_WVZBAVF_STR-SNW201 sy-vline
WA_WVZBAVF_STR-SJBUE sy-vline
WA_WVZBAVF_STR-SNEU_ANL sy-vline
WA_WVZBAVF_STR-XR5_91_1 sy-vline
WA_WVZBAVF_STR-XR5_91_2 sy-vline
WA_WVZBAVF_STR-XR5_91_3 sy-vline
WA_WVZBAVF_STR-XTREU sy-vline
WA_WVZBAVF_STR-XDECK sy-vline
WA_WVZBAVF_STR-XARW sy-vline
WA_WVZBAVF_STR-SMW102 sy-vline
WA_WVZBAVF_STR-X_R97_03 sy-vline
WA_WVZBAVF_STR-X_R97_05 sy-vline
WA_WVZBAVF_STR-X_R97_06 sy-vline
WA_WVZBAVF_STR-X_R97_08 sy-vline
WA_WVZBAVF_STR-X_R97_101 sy-vline
WA_WVZBAVF_STR-X_R97_102 sy-vline
WA_WVZBAVF_STR-X_R97_103 sy-vline
WA_WVZBAVF_STR-X_R97_104 sy-vline
WA_WVZBAVF_STR-XTREU1 sy-vline
WA_WVZBAVF_STR-KZ sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.