ABAP Select data from SAP table WVOBJ_DYN_TABSTRIP_NAMES into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP WVOBJ_DYN_TABSTRIP_NAMES table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to WVOBJ_DYN_TABSTRIP_NAMES. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the WVOBJ_DYN_TABSTRIP_NAMES table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_WVOBJ_DYN_TABSTRIP_NAMES TYPE STANDARD TABLE OF WVOBJ_DYN_TABSTRIP_NAMES, WA_WVOBJ_DYN_TABSTRIP_NAMES TYPE WVOBJ_DYN_TABSTRIP_NAMES, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <WVOBJ_DYN_TABSTRIP_NAMES> TYPE WVOBJ_DYN_TABSTRIP_NAMES. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_WVOBJ_DYN_TABSTRIP_NAMES. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM WVOBJ_DYN_TABSTRIP_NAMES INTO TABLE IT_WVOBJ_DYN_TABSTRIP_NAMES. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM WVOBJ_DYN_TABSTRIP_NAMES * INTO TABLE @DATA(IT_WVOBJ_DYN_TABSTRIP_NAMES2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_WVOBJ_DYN_TABSTRIP_NAMES INDEX 1 INTO DATA(WA_WVOBJ_DYN_TABSTRIP_NAMES2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_WVOBJ_DYN_TABSTRIP_NAMES ASSIGNING <WVOBJ_DYN_TABSTRIP_NAMES>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<WVOBJ_DYN_TABSTRIP_NAMES>-TABS_1 = 1.
<WVOBJ_DYN_TABSTRIP_NAMES>-TABS_2 = 1.
<WVOBJ_DYN_TABSTRIP_NAMES>-TABS_3 = 1.
<WVOBJ_DYN_TABSTRIP_NAMES>-TABS_4 = 1.
<WVOBJ_DYN_TABSTRIP_NAMES>-TABS_5 = 1.
ENDLOOP. LOOP AT IT_WVOBJ_DYN_TABSTRIP_NAMES INTO WA_WVOBJ_DYN_TABSTRIP_NAMES. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_WVOBJ_DYN_TABSTRIP_NAMES-TABS_6, sy-vline,
WA_WVOBJ_DYN_TABSTRIP_NAMES-TABS_7, sy-vline,
WA_WVOBJ_DYN_TABSTRIP_NAMES-TABS_8, sy-vline,
WA_WVOBJ_DYN_TABSTRIP_NAMES-TABS_9, sy-vline,
WA_WVOBJ_DYN_TABSTRIP_NAMES-PROG_1, sy-vline,
WA_WVOBJ_DYN_TABSTRIP_NAMES-PROG_2, sy-vline.
ENDLOOP. *Add any further fields from structure WA_WVOBJ_DYN_TABSTRIP_NAMES you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_WVOBJ_DYN_TABSTRIP_NAMES TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_WVOBJ_DYN_TABSTRIP_NAMES INTO WA_WVOBJ_DYN_TABSTRIP_NAMES. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_WVOBJ_DYN_TABSTRIP_NAMES_STR,
TABS_1 TYPE STRING,
TABS_2 TYPE STRING,
TABS_3 TYPE STRING,
TABS_4 TYPE STRING,
TABS_5 TYPE STRING,
TABS_6 TYPE STRING,
TABS_7 TYPE STRING,
TABS_8 TYPE STRING,
TABS_9 TYPE STRING,
PROG_1 TYPE STRING,
PROG_2 TYPE STRING,
PROG_3 TYPE STRING,
PROG_4 TYPE STRING,
PROG_5 TYPE STRING,
PROG_6 TYPE STRING,
PROG_7 TYPE STRING,
PROG_8 TYPE STRING,
PROG_9 TYPE STRING,
DYNP_1 TYPE STRING,
DYNP_2 TYPE STRING,
DYNP_3 TYPE STRING,
DYNP_4 TYPE STRING,
DYNP_5 TYPE STRING,
DYNP_6 TYPE STRING,
DYNP_7 TYPE STRING,
DYNP_8 TYPE STRING,
DYNP_9 TYPE STRING,END OF T_EKKO_STR. DATA: WA_WVOBJ_DYN_TABSTRIP_NAMES_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_WVOBJ_DYN_TABSTRIP_NAMES_STR-TABS_1 sy-vline
WA_WVOBJ_DYN_TABSTRIP_NAMES_STR-TABS_2 sy-vline
WA_WVOBJ_DYN_TABSTRIP_NAMES_STR-TABS_3 sy-vline
WA_WVOBJ_DYN_TABSTRIP_NAMES_STR-TABS_4 sy-vline
WA_WVOBJ_DYN_TABSTRIP_NAMES_STR-TABS_5 sy-vline
WA_WVOBJ_DYN_TABSTRIP_NAMES_STR-TABS_6 sy-vline
WA_WVOBJ_DYN_TABSTRIP_NAMES_STR-TABS_7 sy-vline
WA_WVOBJ_DYN_TABSTRIP_NAMES_STR-TABS_8 sy-vline
WA_WVOBJ_DYN_TABSTRIP_NAMES_STR-TABS_9 sy-vline
WA_WVOBJ_DYN_TABSTRIP_NAMES_STR-PROG_1 sy-vline
WA_WVOBJ_DYN_TABSTRIP_NAMES_STR-PROG_2 sy-vline
WA_WVOBJ_DYN_TABSTRIP_NAMES_STR-PROG_3 sy-vline
WA_WVOBJ_DYN_TABSTRIP_NAMES_STR-PROG_4 sy-vline
WA_WVOBJ_DYN_TABSTRIP_NAMES_STR-PROG_5 sy-vline
WA_WVOBJ_DYN_TABSTRIP_NAMES_STR-PROG_6 sy-vline
WA_WVOBJ_DYN_TABSTRIP_NAMES_STR-PROG_7 sy-vline
WA_WVOBJ_DYN_TABSTRIP_NAMES_STR-PROG_8 sy-vline
WA_WVOBJ_DYN_TABSTRIP_NAMES_STR-PROG_9 sy-vline
WA_WVOBJ_DYN_TABSTRIP_NAMES_STR-DYNP_1 sy-vline
WA_WVOBJ_DYN_TABSTRIP_NAMES_STR-DYNP_2 sy-vline
WA_WVOBJ_DYN_TABSTRIP_NAMES_STR-DYNP_3 sy-vline
WA_WVOBJ_DYN_TABSTRIP_NAMES_STR-DYNP_4 sy-vline
WA_WVOBJ_DYN_TABSTRIP_NAMES_STR-DYNP_5 sy-vline
WA_WVOBJ_DYN_TABSTRIP_NAMES_STR-DYNP_6 sy-vline
WA_WVOBJ_DYN_TABSTRIP_NAMES_STR-DYNP_7 sy-vline
WA_WVOBJ_DYN_TABSTRIP_NAMES_STR-DYNP_8 sy-vline
WA_WVOBJ_DYN_TABSTRIP_NAMES_STR-DYNP_9 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.