ABAP Select data from SAP table WVFBSTRIN2 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP WVFBSTRIN2 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to WVFBSTRIN2. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the WVFBSTRIN2 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_WVFBSTRIN2 TYPE STANDARD TABLE OF WVFBSTRIN2,
      WA_WVFBSTRIN2 TYPE WVFBSTRIN2,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <WVFBSTRIN2> TYPE WVFBSTRIN2.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_WVFBSTRIN2.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM WVFBSTRIN2
  INTO TABLE IT_WVFBSTRIN2.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM WVFBSTRIN2
*  INTO TABLE @DATA(IT_WVFBSTRIN22).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_WVFBSTRIN2 INDEX 1 INTO DATA(WA_WVFBSTRIN22).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_WVFBSTRIN2 ASSIGNING <WVFBSTRIN2>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<WVFBSTRIN2>-MANDT = 1.
<WVFBSTRIN2>-WGSREQN = 1.
<WVFBSTRIN2>-WGSREQP = 1.
<WVFBSTRIN2>-WBTYP = 1.
<WVFBSTRIN2>-BUKRS = 1.
ENDLOOP.

LOOP AT IT_WVFBSTRIN2 INTO WA_WVFBSTRIN2.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_WVFBSTRIN2-BSTYP, sy-vline,
WA_WVFBSTRIN2-LFART, sy-vline,
WA_WVFBSTRIN2-LIFNR, sy-vline,
WA_WVFBSTRIN2-VSTEL, sy-vline,
WA_WVFBSTRIN2-ROUTE, sy-vline,
WA_WVFBSTRIN2-AUART, sy-vline.
ENDLOOP. *Add any further fields from structure WA_WVFBSTRIN2 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_WVFBSTRIN2 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_WVFBSTRIN2 INTO WA_WVFBSTRIN2. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field WGSREQN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WVFBSTRIN2-WGSREQN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WVFBSTRIN2-WGSREQN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LIFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WVFBSTRIN2-LIFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WVFBSTRIN2-LIFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AUART, internal->external for field AUART CALL FUNCTION 'CONVERSION_EXIT_AUART_OUTPUT' EXPORTING input = WA_WVFBSTRIN2-AUART IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WVFBSTRIN2-AUART.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KUNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WVFBSTRIN2-KUNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WVFBSTRIN2-KUNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_WVFBSTRIN2-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WVFBSTRIN2-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_WVFBSTRIN2-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WVFBSTRIN2-MEINS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EAN11, internal->external for field EAN11 CALL FUNCTION 'CONVERSION_EXIT_EAN11_OUTPUT' EXPORTING input = WA_WVFBSTRIN2-EAN11 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WVFBSTRIN2-EAN11.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AKTNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WVFBSTRIN2-AKTNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WVFBSTRIN2-AKTNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_WVFBSTRIN2_STR,
MANDT TYPE STRING,
WGSREQN TYPE STRING,
WGSREQP TYPE STRING,
WBTYP TYPE STRING,
BUKRS TYPE STRING,
BSTYP TYPE STRING,
LFART TYPE STRING,
LIFNR TYPE STRING,
VSTEL TYPE STRING,
ROUTE TYPE STRING,
AUART TYPE STRING,
VKORG TYPE STRING,
VTWEG TYPE STRING,
SPART TYPE STRING,
EKGRP TYPE STRING,
DISPO TYPE STRING,
KUNNR TYPE STRING,
RESWK TYPE STRING,
MATNR TYPE STRING,
WERKS TYPE STRING,
BEDNR TYPE STRING,
MATKL TYPE STRING,
IDNLF TYPE STRING,
MENGE TYPE STRING,
MEINS TYPE STRING,
EAN11 TYPE STRING,
AKTNR TYPE STRING,
EINDT TYPE STRING,
UZEIT TYPE STRING,
BEDAT TYPE STRING,
VSTAT TYPE STRING,
POSNRI TYPE STRING,END OF T_EKKO_STR. DATA: WA_WVFBSTRIN2_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_WVFBSTRIN2_STR-MANDT sy-vline
WA_WVFBSTRIN2_STR-WGSREQN sy-vline
WA_WVFBSTRIN2_STR-WGSREQP sy-vline
WA_WVFBSTRIN2_STR-WBTYP sy-vline
WA_WVFBSTRIN2_STR-BUKRS sy-vline
WA_WVFBSTRIN2_STR-BSTYP sy-vline
WA_WVFBSTRIN2_STR-LFART sy-vline
WA_WVFBSTRIN2_STR-LIFNR sy-vline
WA_WVFBSTRIN2_STR-VSTEL sy-vline
WA_WVFBSTRIN2_STR-ROUTE sy-vline
WA_WVFBSTRIN2_STR-AUART sy-vline
WA_WVFBSTRIN2_STR-VKORG sy-vline
WA_WVFBSTRIN2_STR-VTWEG sy-vline
WA_WVFBSTRIN2_STR-SPART sy-vline
WA_WVFBSTRIN2_STR-EKGRP sy-vline
WA_WVFBSTRIN2_STR-DISPO sy-vline
WA_WVFBSTRIN2_STR-KUNNR sy-vline
WA_WVFBSTRIN2_STR-RESWK sy-vline
WA_WVFBSTRIN2_STR-MATNR sy-vline
WA_WVFBSTRIN2_STR-WERKS sy-vline
WA_WVFBSTRIN2_STR-BEDNR sy-vline
WA_WVFBSTRIN2_STR-MATKL sy-vline
WA_WVFBSTRIN2_STR-IDNLF sy-vline
WA_WVFBSTRIN2_STR-MENGE sy-vline
WA_WVFBSTRIN2_STR-MEINS sy-vline
WA_WVFBSTRIN2_STR-EAN11 sy-vline
WA_WVFBSTRIN2_STR-AKTNR sy-vline
WA_WVFBSTRIN2_STR-EINDT sy-vline
WA_WVFBSTRIN2_STR-UZEIT sy-vline
WA_WVFBSTRIN2_STR-BEDAT sy-vline
WA_WVFBSTRIN2_STR-VSTAT sy-vline
WA_WVFBSTRIN2_STR-POSNRI sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.