ABAP Select data from SAP table WTYBRF_PMCS_NOT_ITM into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP WTYBRF_PMCS_NOT_ITM table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to WTYBRF_PMCS_NOT_ITM. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the WTYBRF_PMCS_NOT_ITM table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_WTYBRF_PMCS_NOT_ITM TYPE STANDARD TABLE OF WTYBRF_PMCS_NOT_ITM,
      WA_WTYBRF_PMCS_NOT_ITM TYPE WTYBRF_PMCS_NOT_ITM,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <WTYBRF_PMCS_NOT_ITM> TYPE WTYBRF_PMCS_NOT_ITM.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_WTYBRF_PMCS_NOT_ITM.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM WTYBRF_PMCS_NOT_ITM
  INTO TABLE IT_WTYBRF_PMCS_NOT_ITM.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM WTYBRF_PMCS_NOT_ITM
*  INTO TABLE @DATA(IT_WTYBRF_PMCS_NOT_ITM2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_WTYBRF_PMCS_NOT_ITM INDEX 1 INTO DATA(WA_WTYBRF_PMCS_NOT_ITM2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_WTYBRF_PMCS_NOT_ITM ASSIGNING <WTYBRF_PMCS_NOT_ITM>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<WTYBRF_PMCS_NOT_ITM>-NOTIF_NO = 1.
<WTYBRF_PMCS_NOT_ITM>-ITEM_KEY = 1.
<WTYBRF_PMCS_NOT_ITM>-CREATED_BY = 1.
<WTYBRF_PMCS_NOT_ITM>-CREATED_DATE = 1.
<WTYBRF_PMCS_NOT_ITM>-CHANGED_BY = 1.
ENDLOOP.

LOOP AT IT_WTYBRF_PMCS_NOT_ITM INTO WA_WTYBRF_PMCS_NOT_ITM.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_WTYBRF_PMCS_NOT_ITM-CHANGED_DATE, sy-vline,
WA_WTYBRF_PMCS_NOT_ITM-DESCRIPT, sy-vline,
WA_WTYBRF_PMCS_NOT_ITM-D_CAT_TYP, sy-vline,
WA_WTYBRF_PMCS_NOT_ITM-D_CODEGRP, sy-vline,
WA_WTYBRF_PMCS_NOT_ITM-D_CODE, sy-vline,
WA_WTYBRF_PMCS_NOT_ITM-DL_CAT_TYP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_WTYBRF_PMCS_NOT_ITM you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_WTYBRF_PMCS_NOT_ITM TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_WTYBRF_PMCS_NOT_ITM INTO WA_WTYBRF_PMCS_NOT_ITM. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field NOTIF_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WTYBRF_PMCS_NOT_ITM-NOTIF_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTYBRF_PMCS_NOT_ITM-NOTIF_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN5, internal->external for field ASSEMBLY CALL FUNCTION 'CONVERSION_EXIT_MATN5_OUTPUT' EXPORTING input = WA_WTYBRF_PMCS_NOT_ITM-ASSEMBLY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTYBRF_PMCS_NOT_ITM-ASSEMBLY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATNL, internal->external for field ASSEMBLY_EXTERNAL CALL FUNCTION 'CONVERSION_EXIT_MATNL_OUTPUT' EXPORTING input = WA_WTYBRF_PMCS_NOT_ITM-ASSEMBLY_EXTERNAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTYBRF_PMCS_NOT_ITM-ASSEMBLY_EXTERNAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATNW, internal->external for field ASSEMBLY_VERSION CALL FUNCTION 'CONVERSION_EXIT_MATNW_OUTPUT' EXPORTING input = WA_WTYBRF_PMCS_NOT_ITM-ASSEMBLY_VERSION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTYBRF_PMCS_NOT_ITM-ASSEMBLY_VERSION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field LINEAR_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_WTYBRF_PMCS_NOT_ITM-LINEAR_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTYBRF_PMCS_NOT_ITM-LINEAR_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field FIRST_OFFSET_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_WTYBRF_PMCS_NOT_ITM-FIRST_OFFSET_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTYBRF_PMCS_NOT_ITM-FIRST_OFFSET_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field SECOND_OFFSET_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_WTYBRF_PMCS_NOT_ITM-SECOND_OFFSET_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTYBRF_PMCS_NOT_ITM-SECOND_OFFSET_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQUIPMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WTYBRF_PMCS_NOT_ITM-EQUIPMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTYBRF_PMCS_NOT_ITM-EQUIPMENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field FUNCT_LOC CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_WTYBRF_PMCS_NOT_ITM-FUNCT_LOC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTYBRF_PMCS_NOT_ITM-FUNCT_LOC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MARKER_DISTANCE_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_WTYBRF_PMCS_NOT_ITM-MARKER_DISTANCE_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTYBRF_PMCS_NOT_ITM-MARKER_DISTANCE_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field ASSEMBLY_LONG CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_WTYBRF_PMCS_NOT_ITM-ASSEMBLY_LONG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTYBRF_PMCS_NOT_ITM-ASSEMBLY_LONG.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_WTYBRF_PMCS_NOT_ITM_STR,
NOTIF_NO TYPE STRING,
ITEM_KEY TYPE STRING,
CREATED_BY TYPE STRING,
CREATED_DATE TYPE STRING,
CHANGED_BY TYPE STRING,
CHANGED_DATE TYPE STRING,
DESCRIPT TYPE STRING,
D_CAT_TYP TYPE STRING,
D_CODEGRP TYPE STRING,
D_CODE TYPE STRING,
DL_CAT_TYP TYPE STRING,
DL_CODEGRP TYPE STRING,
DL_CODE TYPE STRING,
ASSEMBLY TYPE STRING,
LONG_TEXT TYPE STRING,
PRILANG TYPE STRING,
POS_TIME TYPE STRING,
CHANGE_TIME TYPE STRING,
DELETE_FLAG TYPE STRING,
ITEM_SORT_NO TYPE STRING,
STXT_GRPCD TYPE STRING,
TXT_PROBCD TYPE STRING,
TXT_GRPCD TYPE STRING,
TXT_OBJPTCD TYPE STRING,
CLASSIF TYPE STRING,
CLASSIF_DESC TYPE STRING,
INTCLASSNR TYPE STRING,
TXT_PART TYPE STRING,
CLASS_TYPE TYPE STRING,
ASSEMBLY_EXTERNAL TYPE STRING,
ASSEMBLY_GUID TYPE STRING,
ASSEMBLY_VERSION TYPE STRING,
START_POINT TYPE STRING,
END_POINT TYPE STRING,
LINEAR_LENGTH TYPE STRING,
LINEAR_UNIT TYPE STRING,
LINEAR_UNIT_ISO TYPE STRING,
FIRST_OFFSET_TYPE_CODE TYPE STRING,
FIRST_OFFSET_VALUE TYPE STRING,
FIRST_OFFSET_UNIT TYPE STRING,
FIRST_OFFSET_UNIT_ISO TYPE STRING,
SECOND_OFFSET_TYPE_CODE TYPE STRING,
SECOND_OFFSET_VALUE TYPE STRING,
SECOND_OFFSET_UNIT TYPE STRING,
SECOND_OFFSET_UNIT_ISO TYPE STRING,
FIRST_OFFSET_TYPE_CODE_NAME TYPE STRING,
SECOND_OFFSET_TYPE_CODE_NAME TYPE STRING,
EQUIPMENT TYPE STRING,
EQUIDESCR TYPE STRING,
FUNCT_LOC TYPE STRING,
FUNCLDESCR TYPE STRING,
MARKER_START_POINT TYPE STRING,
MARKER_DISTANCE_START_POINT TYPE STRING,
MARKER_END_POINT TYPE STRING,
MARKER_DISTANCE_END_POINT TYPE STRING,
MARKER_DISTANCE_UNIT TYPE STRING,
MARKER_DISTANCE_UNIT_ISO TYPE STRING,
ASSEMBLY_LONG TYPE STRING,END OF T_EKKO_STR. DATA: WA_WTYBRF_PMCS_NOT_ITM_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-NOTIF_NO sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-ITEM_KEY sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-CREATED_BY sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-CREATED_DATE sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-CHANGED_BY sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-CHANGED_DATE sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-DESCRIPT sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-D_CAT_TYP sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-D_CODEGRP sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-D_CODE sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-DL_CAT_TYP sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-DL_CODEGRP sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-DL_CODE sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-ASSEMBLY sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-LONG_TEXT sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-PRILANG sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-POS_TIME sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-CHANGE_TIME sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-DELETE_FLAG sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-ITEM_SORT_NO sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-STXT_GRPCD sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-TXT_PROBCD sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-TXT_GRPCD sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-TXT_OBJPTCD sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-CLASSIF sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-CLASSIF_DESC sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-INTCLASSNR sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-TXT_PART sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-CLASS_TYPE sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-ASSEMBLY_EXTERNAL sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-ASSEMBLY_GUID sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-ASSEMBLY_VERSION sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-START_POINT sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-END_POINT sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-LINEAR_LENGTH sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-LINEAR_UNIT sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-LINEAR_UNIT_ISO sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-FIRST_OFFSET_TYPE_CODE sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-FIRST_OFFSET_VALUE sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-FIRST_OFFSET_UNIT sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-FIRST_OFFSET_UNIT_ISO sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-SECOND_OFFSET_TYPE_CODE sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-SECOND_OFFSET_VALUE sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-SECOND_OFFSET_UNIT sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-SECOND_OFFSET_UNIT_ISO sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-FIRST_OFFSET_TYPE_CODE_NAME sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-SECOND_OFFSET_TYPE_CODE_NAME sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-EQUIPMENT sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-EQUIDESCR sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-FUNCT_LOC sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-FUNCLDESCR sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-MARKER_START_POINT sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-MARKER_DISTANCE_START_POINT sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-MARKER_END_POINT sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-MARKER_DISTANCE_END_POINT sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-MARKER_DISTANCE_UNIT sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-MARKER_DISTANCE_UNIT_ISO sy-vline
WA_WTYBRF_PMCS_NOT_ITM_STR-ASSEMBLY_LONG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.