ABAP Select data from SAP table WTYBRF_CON_CON into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP WTYBRF_CON_CON table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to WTYBRF_CON_CON. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the WTYBRF_CON_CON table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_WTYBRF_CON_CON TYPE STANDARD TABLE OF WTYBRF_CON_CON,
      WA_WTYBRF_CON_CON TYPE WTYBRF_CON_CON,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <WTYBRF_CON_CON> TYPE WTYBRF_CON_CON.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_WTYBRF_CON_CON.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM WTYBRF_CON_CON
  INTO TABLE IT_WTYBRF_CON_CON.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM WTYBRF_CON_CON
*  INTO TABLE @DATA(IT_WTYBRF_CON_CON2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_WTYBRF_CON_CON INDEX 1 INTO DATA(WA_WTYBRF_CON_CON2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_WTYBRF_CON_CON ASSIGNING <WTYBRF_CON_CON>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<WTYBRF_CON_CON>-MANDT = 1.
<WTYBRF_CON_CON>-VBELN = 1.
<WTYBRF_CON_CON>-VPOSN = 1.
<WTYBRF_CON_CON>-VLAUFZ = 1.
<WTYBRF_CON_CON>-VLAUEZ = 1.
ENDLOOP.

LOOP AT IT_WTYBRF_CON_CON INTO WA_WTYBRF_CON_CON.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_WTYBRF_CON_CON-VLAUFK, sy-vline,
WA_WTYBRF_CON_CON-VINSDAT, sy-vline,
WA_WTYBRF_CON_CON-VABNDAT, sy-vline,
WA_WTYBRF_CON_CON-VBEGDAT, sy-vline,
WA_WTYBRF_CON_CON-VUNTDAT, sy-vline,
WA_WTYBRF_CON_CON-VKUESCH, sy-vline.
ENDLOOP. *Add any further fields from structure WA_WTYBRF_CON_CON you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_WTYBRF_CON_CON TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_WTYBRF_CON_CON INTO WA_WTYBRF_CON_CON. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field VBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WTYBRF_CON_CON-VBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTYBRF_CON_CON-VBELN.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_WTYBRF_CON_CON_STR,
MANDT TYPE STRING,
VBELN TYPE STRING,
VPOSN TYPE STRING,
VLAUFZ TYPE STRING,
VLAUEZ TYPE STRING,
VLAUFK TYPE STRING,
VINSDAT TYPE STRING,
VABNDAT TYPE STRING,
VBEGDAT TYPE STRING,
VUNTDAT TYPE STRING,
VKUESCH TYPE STRING,
VAKTSCH TYPE STRING,
VEINDAT TYPE STRING,
VWUNDAT TYPE STRING,
VKUEPAR TYPE STRING,
VKUEGRU TYPE STRING,
VENDDAT TYPE STRING,
VBELKUE TYPE STRING,
VBEDKUE TYPE STRING,
VBEGREG TYPE STRING,
VVORZEIT TYPE STRING,
VVOREIN TYPE STRING,
VDEMDAT TYPE STRING,
VASDA TYPE STRING,
WIMID TYPE STRING,
VASDR TYPE STRING,
VENDREG TYPE STRING,
_DATAAGING TYPE STRING,END OF T_EKKO_STR. DATA: WA_WTYBRF_CON_CON_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_WTYBRF_CON_CON_STR-MANDT sy-vline
WA_WTYBRF_CON_CON_STR-VBELN sy-vline
WA_WTYBRF_CON_CON_STR-VPOSN sy-vline
WA_WTYBRF_CON_CON_STR-VLAUFZ sy-vline
WA_WTYBRF_CON_CON_STR-VLAUEZ sy-vline
WA_WTYBRF_CON_CON_STR-VLAUFK sy-vline
WA_WTYBRF_CON_CON_STR-VINSDAT sy-vline
WA_WTYBRF_CON_CON_STR-VABNDAT sy-vline
WA_WTYBRF_CON_CON_STR-VBEGDAT sy-vline
WA_WTYBRF_CON_CON_STR-VUNTDAT sy-vline
WA_WTYBRF_CON_CON_STR-VKUESCH sy-vline
WA_WTYBRF_CON_CON_STR-VAKTSCH sy-vline
WA_WTYBRF_CON_CON_STR-VEINDAT sy-vline
WA_WTYBRF_CON_CON_STR-VWUNDAT sy-vline
WA_WTYBRF_CON_CON_STR-VKUEPAR sy-vline
WA_WTYBRF_CON_CON_STR-VKUEGRU sy-vline
WA_WTYBRF_CON_CON_STR-VENDDAT sy-vline
WA_WTYBRF_CON_CON_STR-VBELKUE sy-vline
WA_WTYBRF_CON_CON_STR-VBEDKUE sy-vline
WA_WTYBRF_CON_CON_STR-VBEGREG sy-vline
WA_WTYBRF_CON_CON_STR-VVORZEIT sy-vline
WA_WTYBRF_CON_CON_STR-VVOREIN sy-vline
WA_WTYBRF_CON_CON_STR-VDEMDAT sy-vline
WA_WTYBRF_CON_CON_STR-VASDA sy-vline
WA_WTYBRF_CON_CON_STR-WIMID sy-vline
WA_WTYBRF_CON_CON_STR-VASDR sy-vline
WA_WTYBRF_CON_CON_STR-VENDREG sy-vline
WA_WTYBRF_CON_CON_STR-_DATAAGING sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.