ABAP Select data from SAP table WTY_VELO_LDB into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP WTY_VELO_LDB table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to WTY_VELO_LDB. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the WTY_VELO_LDB table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_WTY_VELO_LDB TYPE STANDARD TABLE OF WTY_VELO_LDB,
      WA_WTY_VELO_LDB TYPE WTY_VELO_LDB,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <WTY_VELO_LDB> TYPE WTY_VELO_LDB.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_WTY_VELO_LDB.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM WTY_VELO_LDB
  INTO TABLE IT_WTY_VELO_LDB.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM WTY_VELO_LDB
*  INTO TABLE @DATA(IT_WTY_VELO_LDB2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_WTY_VELO_LDB INDEX 1 INTO DATA(WA_WTY_VELO_LDB2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_WTY_VELO_LDB ASSIGNING <WTY_VELO_LDB>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<WTY_VELO_LDB>-FDUMMY = 1.
<WTY_VELO_LDB>-MANDT = 1.
<WTY_VELO_LDB>-VGUID = 1.
<WTY_VELO_LDB>-VHCLE = 1.
<WTY_VELO_LDB>-MATNR = 1.
ENDLOOP.

LOOP AT IT_WTY_VELO_LDB INTO WA_WTY_VELO_LDB.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_WTY_VELO_LDB-LIFNR, sy-vline,
WA_WTY_VELO_LDB-CHARG, sy-vline,
WA_WTY_VELO_LDB-EQUNR, sy-vline,
WA_WTY_VELO_LDB-WERKS, sy-vline,
WA_WTY_VELO_LDB-LGORT, sy-vline,
WA_WTY_VELO_LDB-BWTAR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_WTY_VELO_LDB you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_WTY_VELO_LDB TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_WTY_VELO_LDB INTO WA_WTY_VELO_LDB. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_WTY_VELO_LDB-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTY_VELO_LDB-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LIFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WTY_VELO_LDB-LIFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTY_VELO_LDB-LIFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQUNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WTY_VELO_LDB-EQUNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTY_VELO_LDB-EQUNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KUNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WTY_VELO_LDB-KUNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTY_VELO_LDB-KUNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ENDCU CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WTY_VELO_LDB-ENDCU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTY_VELO_LDB-ENDCU.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PCOUNT_U CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_WTY_VELO_LDB-PCOUNT_U IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTY_VELO_LDB-PCOUNT_U.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VHORD CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WTY_VELO_LDB-VHORD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTY_VELO_LDB-VHORD.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_WTY_VELO_LDB_STR,
FDUMMY TYPE STRING,
MANDT TYPE STRING,
VGUID TYPE STRING,
VHCLE TYPE STRING,
MATNR TYPE STRING,
LIFNR TYPE STRING,
CHARG TYPE STRING,
EQUNR TYPE STRING,
WERKS TYPE STRING,
LGORT TYPE STRING,
BWTAR TYPE STRING,
CUOBJ TYPE STRING,
CUABA TYPE STRING,
MMCTR TYPE STRING,
MMSTA TYPE STRING,
MMTSP TYPE STRING,
SDCTR TYPE STRING,
SDSTA TYPE STRING,
SDTSP TYPE STRING,
KUNNR TYPE STRING,
ENDCU TYPE STRING,
VHVIN TYPE STRING,
VHCEX TYPE STRING,
AVAIL TYPE STRING,
VBLTY TYPE STRING,
LOCTN TYPE STRING,
GPRICE TYPE STRING,
GPRICECUKY TYPE STRING,
CDTSP TYPE STRING,
PSTSP TYPE STRING,
PDTSP TYPE STRING,
ERNAM TYPE STRING,
VHUSG TYPE STRING,
CMPGN TYPE STRING,
PCOUNT TYPE STRING,
PCOUNT_U TYPE STRING,
IMMATDATE TYPE STRING,
VHSAR TYPE STRING,
VHORD TYPE STRING,
SHLVL TYPE STRING,
ARCHIVE_FLAG TYPE STRING,
USED_VEHICLE TYPE STRING,
DIGITALVEHICLEREFERENCEID TYPE STRING,END OF T_EKKO_STR. DATA: WA_WTY_VELO_LDB_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_WTY_VELO_LDB_STR-FDUMMY sy-vline
WA_WTY_VELO_LDB_STR-MANDT sy-vline
WA_WTY_VELO_LDB_STR-VGUID sy-vline
WA_WTY_VELO_LDB_STR-VHCLE sy-vline
WA_WTY_VELO_LDB_STR-MATNR sy-vline
WA_WTY_VELO_LDB_STR-LIFNR sy-vline
WA_WTY_VELO_LDB_STR-CHARG sy-vline
WA_WTY_VELO_LDB_STR-EQUNR sy-vline
WA_WTY_VELO_LDB_STR-WERKS sy-vline
WA_WTY_VELO_LDB_STR-LGORT sy-vline
WA_WTY_VELO_LDB_STR-BWTAR sy-vline
WA_WTY_VELO_LDB_STR-CUOBJ sy-vline
WA_WTY_VELO_LDB_STR-CUABA sy-vline
WA_WTY_VELO_LDB_STR-MMCTR sy-vline
WA_WTY_VELO_LDB_STR-MMSTA sy-vline
WA_WTY_VELO_LDB_STR-MMTSP sy-vline
WA_WTY_VELO_LDB_STR-SDCTR sy-vline
WA_WTY_VELO_LDB_STR-SDSTA sy-vline
WA_WTY_VELO_LDB_STR-SDTSP sy-vline
WA_WTY_VELO_LDB_STR-KUNNR sy-vline
WA_WTY_VELO_LDB_STR-ENDCU sy-vline
WA_WTY_VELO_LDB_STR-VHVIN sy-vline
WA_WTY_VELO_LDB_STR-VHCEX sy-vline
WA_WTY_VELO_LDB_STR-AVAIL sy-vline
WA_WTY_VELO_LDB_STR-VBLTY sy-vline
WA_WTY_VELO_LDB_STR-LOCTN sy-vline
WA_WTY_VELO_LDB_STR-GPRICE sy-vline
WA_WTY_VELO_LDB_STR-GPRICECUKY sy-vline
WA_WTY_VELO_LDB_STR-CDTSP sy-vline
WA_WTY_VELO_LDB_STR-PSTSP sy-vline
WA_WTY_VELO_LDB_STR-PDTSP sy-vline
WA_WTY_VELO_LDB_STR-ERNAM sy-vline
WA_WTY_VELO_LDB_STR-VHUSG sy-vline
WA_WTY_VELO_LDB_STR-CMPGN sy-vline
WA_WTY_VELO_LDB_STR-PCOUNT sy-vline
WA_WTY_VELO_LDB_STR-PCOUNT_U sy-vline
WA_WTY_VELO_LDB_STR-IMMATDATE sy-vline
WA_WTY_VELO_LDB_STR-VHSAR sy-vline
WA_WTY_VELO_LDB_STR-VHORD sy-vline
WA_WTY_VELO_LDB_STR-SHLVL sy-vline
WA_WTY_VELO_LDB_STR-ARCHIVE_FLAG sy-vline
WA_WTY_VELO_LDB_STR-USED_VEHICLE sy-vline
WA_WTY_VELO_LDB_STR-DIGITALVEHICLEREFERENCEID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.