ABAP Select data from SAP table WTY_PNWTYV_DIA_WEB into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP WTY_PNWTYV_DIA_WEB table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to WTY_PNWTYV_DIA_WEB. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the WTY_PNWTYV_DIA_WEB table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_WTY_PNWTYV_DIA_WEB TYPE STANDARD TABLE OF WTY_PNWTYV_DIA_WEB,
      WA_WTY_PNWTYV_DIA_WEB TYPE WTY_PNWTYV_DIA_WEB,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <WTY_PNWTYV_DIA_WEB> TYPE WTY_PNWTYV_DIA_WEB.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_WTY_PNWTYV_DIA_WEB.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM WTY_PNWTYV_DIA_WEB
  INTO TABLE IT_WTY_PNWTYV_DIA_WEB.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM WTY_PNWTYV_DIA_WEB
*  INTO TABLE @DATA(IT_WTY_PNWTYV_DIA_WEB2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_WTY_PNWTYV_DIA_WEB INDEX 1 INTO DATA(WA_WTY_PNWTYV_DIA_WEB2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_WTY_PNWTYV_DIA_WEB ASSIGNING <WTY_PNWTYV_DIA_WEB>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<WTY_PNWTYV_DIA_WEB>-MANDT = 1.
<WTY_PNWTYV_DIA_WEB>-PNGUID = 1.
<WTY_PNWTYV_DIA_WEB>-PNCNT = 1.
<WTY_PNWTYV_DIA_WEB>-HANDLE = 1.
<WTY_PNWTYV_DIA_WEB>-PNTXCNT = 1.
ENDLOOP.

LOOP AT IT_WTY_PNWTYV_DIA_WEB INTO WA_WTY_PNWTYV_DIA_WEB.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_WTY_PNWTYV_DIA_WEB-VERSN, sy-vline,
WA_WTY_PNWTYV_DIA_WEB-KATEG, sy-vline,
WA_WTY_PNWTYV_DIA_WEB-V_REJCD, sy-vline,
WA_WTY_PNWTYV_DIA_WEB-V_PARNR, sy-vline,
WA_WTY_PNWTYV_DIA_WEB-V_PARVW, sy-vline,
WA_WTY_PNWTYV_DIA_WEB-REFKT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_WTY_PNWTYV_DIA_WEB you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_WTY_PNWTYV_DIA_WEB TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_WTY_PNWTYV_DIA_WEB INTO WA_WTY_PNWTYV_DIA_WEB. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field V_PARNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WTY_PNWTYV_DIA_WEB-V_PARNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTY_PNWTYV_DIA_WEB-V_PARNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PARVW, internal->external for field V_PARVW CALL FUNCTION 'CONVERSION_EXIT_PARVW_OUTPUT' EXPORTING input = WA_WTY_PNWTYV_DIA_WEB-V_PARVW IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTY_PNWTYV_DIA_WEB-V_PARVW.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXCRT, internal->external for field KURSK CALL FUNCTION 'CONVERSION_EXIT_EXCRT_OUTPUT' EXPORTING input = WA_WTY_PNWTYV_DIA_WEB-KURSK IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTY_PNWTYV_DIA_WEB-KURSK.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SDVBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WTY_PNWTYV_DIA_WEB-SDVBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTY_PNWTYV_DIA_WEB-SDVBELN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field V_MGANR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WTY_PNWTYV_DIA_WEB-V_MGANR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTY_PNWTYV_DIA_WEB-V_MGANR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KUNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WTY_PNWTYV_DIA_WEB-KUNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTY_PNWTYV_DIA_WEB-KUNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field V_ADRNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WTY_PNWTYV_DIA_WEB-V_ADRNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTY_PNWTYV_DIA_WEB-V_ADRNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit LUNIT, internal->external for field LAST_MEASUREM_UNIT CALL FUNCTION 'CONVERSION_EXIT_LUNIT_OUTPUT' EXPORTING input = WA_WTY_PNWTYV_DIA_WEB-LAST_MEASUREM_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTY_PNWTYV_DIA_WEB-LAST_MEASUREM_UNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_WTY_PNWTYV_DIA_WEB_STR,
MANDT TYPE STRING,
PNGUID TYPE STRING,
PNCNT TYPE STRING,
HANDLE TYPE STRING,
PNTXCNT TYPE STRING,
VERSN TYPE STRING,
KATEG TYPE STRING,
V_REJCD TYPE STRING,
V_PARNR TYPE STRING,
V_PARVW TYPE STRING,
REFKT TYPE STRING,
REFNR TYPE STRING,
AKTIV TYPE STRING,
FKDAT TYPE STRING,
KNUMV TYPE STRING,
V_CRNCY TYPE STRING,
PRSDT TYPE STRING,
KURSK TYPE STRING,
V_LOG_HANDLE TYPE STRING,
LOG_HDL_DFCT TYPE STRING,
PREV_VERSION TYPE STRING,
VKORG TYPE STRING,
VTWEG TYPE STRING,
SPART TYPE STRING,
V_MDOCM TYPE STRING,
REVERSAL TYPE STRING,
ENDVN TYPE STRING,
EKORG TYPE STRING,
SDVBELN TYPE STRING,
SDPOSNR TYPE STRING,
REFDT_VERS TYPE STRING,
V_MGANR TYPE STRING,
V_GWLDT TYPE STRING,
RESULT_OUT_MWTYV TYPE STRING,
RESULT_IN_MWTYV TYPE STRING,
V_DUMMY TYPE STRING,
PRICING_OK TYPE STRING,
NEW_VERSION TYPE STRING,
COMPSEND TYPE STRING,
TIMSTMP TYPE STRING,
CREADAT TYPE STRING,
CREABY TYPE STRING,
CHNGDAT TYPE STRING,
CHNGBY TYPE STRING,
HEADER_GUID TYPE STRING,
PNTEXT TYPE STRING,
SUM_SUBL TYPE STRING,
SUM_MAT TYPE STRING,
SUM_FR TYPE STRING,
LAND1 TYPE STRING,
NAME1 TYPE STRING,
ORT01 TYPE STRING,
KUNNR TYPE STRING,
REJCD_TXT TYPE STRING,
V_DISTANCE TYPE STRING,
V_D_UNIT TYPE STRING,
REF_VERSN TYPE STRING,
FI_POST TYPE STRING,
V_CREADAT TYPE STRING,
V_CREABY TYPE STRING,
V_CHNGDAT TYPE STRING,
V_CHNGBY TYPE STRING,
TEXT_EXISTS TYPE STRING,
FI_DOC_EXIST TYPE STRING,
LOG_MEMO_VER TYPE STRING,
LOG_MEMO_DFCT TYPE STRING,
V_ADRNR TYPE STRING,
CHANGE_FLAG TYPE STRING,
V_MEASURE_POINT TYPE STRING,
LF_FLAG TYPE STRING,
LAST_MEASUREMENT TYPE STRING,
LAST_MEASUREM_UNIT TYPE STRING,
BLART_R TYPE STRING,
BLART_P TYPE STRING,END OF T_EKKO_STR. DATA: WA_WTY_PNWTYV_DIA_WEB_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-MANDT sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-PNGUID sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-PNCNT sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-HANDLE sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-PNTXCNT sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-VERSN sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-KATEG sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-V_REJCD sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-V_PARNR sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-V_PARVW sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-REFKT sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-REFNR sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-AKTIV sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-FKDAT sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-KNUMV sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-V_CRNCY sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-PRSDT sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-KURSK sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-V_LOG_HANDLE sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-LOG_HDL_DFCT sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-PREV_VERSION sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-VKORG sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-VTWEG sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-SPART sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-V_MDOCM sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-REVERSAL sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-ENDVN sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-EKORG sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-SDVBELN sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-SDPOSNR sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-REFDT_VERS sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-V_MGANR sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-V_GWLDT sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-RESULT_OUT_MWTYV sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-RESULT_IN_MWTYV sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-V_DUMMY sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-PRICING_OK sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-NEW_VERSION sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-COMPSEND sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-TIMSTMP sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-CREADAT sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-CREABY sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-CHNGDAT sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-CHNGBY sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-HEADER_GUID sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-PNTEXT sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-SUM_SUBL sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-SUM_MAT sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-SUM_FR sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-LAND1 sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-NAME1 sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-ORT01 sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-KUNNR sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-REJCD_TXT sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-V_DISTANCE sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-V_D_UNIT sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-REF_VERSN sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-FI_POST sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-V_CREADAT sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-V_CREABY sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-V_CHNGDAT sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-V_CHNGBY sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-TEXT_EXISTS sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-FI_DOC_EXIST sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-LOG_MEMO_VER sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-LOG_MEMO_DFCT sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-V_ADRNR sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-CHANGE_FLAG sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-V_MEASURE_POINT sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-LF_FLAG sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-LAST_MEASUREMENT sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-LAST_MEASUREM_UNIT sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-BLART_R sy-vline
WA_WTY_PNWTYV_DIA_WEB_STR-BLART_P sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.