ABAP Select data from SAP table WTAKP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP WTAKP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to WTAKP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the WTAKP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_WTAKP TYPE STANDARD TABLE OF WTAKP,
      WA_WTAKP TYPE WTAKP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <WTAKP> TYPE WTAKP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_WTAKP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM WTAKP
  INTO TABLE IT_WTAKP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM WTAKP
*  INTO TABLE @DATA(IT_WTAKP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_WTAKP INDEX 1 INTO DATA(WA_WTAKP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_WTAKP ASSIGNING <WTAKP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<WTAKP>-MANDT = 1.
<WTAKP>-BUKRS = 1.
<WTAKP>-LIFNR = 1.
<WTAKP>-WT_CALY = 1.
<WTAKP>-WITHT = 1.
ENDLOOP.

LOOP AT IT_WTAKP INTO WA_WTAKP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_WTAKP-WT_WITHCD, sy-vline,
WA_WTAKP-LAUFD, sy-vline,
WA_WTAKP-LAUFI, sy-vline,
WA_WTAKP-WT_BS01, sy-vline,
WA_WTAKP-WT_WT01, sy-vline,
WA_WTAKP-WT_HLP01, sy-vline.
ENDLOOP. *Add any further fields from structure WA_WTAKP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_WTAKP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_WTAKP INTO WA_WTAKP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field LIFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WTAKP-LIFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-LIFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field WT_CALY CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_WTAKP-WT_CALY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_CALY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_BS01 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_BS01 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_BS01.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_WT01 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_WT01 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_WT01.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_HLP01 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_HLP01 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_HLP01.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_HLPA01 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_HLPA01 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_HLPA01.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_BS02 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_BS02 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_BS02.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_WT02 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_WT02 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_WT02.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_HLP02 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_HLP02 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_HLP02.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_HLPA02 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_HLPA02 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_HLPA02.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_BS03 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_BS03 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_BS03.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_WT03 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_WT03 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_WT03.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_HLP03 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_HLP03 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_HLP03.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_HLPA03 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_HLPA03 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_HLPA03.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_BS04 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_BS04 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_BS04.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_WT04 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_WT04 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_WT04.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_HLP04 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_HLP04 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_HLP04.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_HLPA04 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_HLPA04 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_HLPA04.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_BS05 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_BS05 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_BS05.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_WT05 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_WT05 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_WT05.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_HLP05 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_HLP05 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_HLP05.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_HLPA05 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_HLPA05 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_HLPA05.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_BS06 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_BS06 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_BS06.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_WT06 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_WT06 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_WT06.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_HLP06 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_HLP06 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_HLP06.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_HLPA06 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_HLPA06 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_HLPA06.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_BS07 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_BS07 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_BS07.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_WT07 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_WT07 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_WT07.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_HLP07 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_HLP07 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_HLP07.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_HLPA07 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_HLPA07 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_HLPA07.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_BS08 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_BS08 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_BS08.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_WT08 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_WT08 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_WT08.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_HLP08 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_HLP08 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_HLP08.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_HLPA08 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_HLPA08 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_HLPA08.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_BS09 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_BS09 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_BS09.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_WT09 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_WT09 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_WT09.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_HLP09 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_HLP09 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_HLP09.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_HLPA09 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_HLPA09 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_HLPA09.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_BS10 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_BS10 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_BS10.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_WT10 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_WT10 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_WT10.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_HLP10 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_HLP10 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_HLP10.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_HLPA10 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_HLPA10 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_HLPA10.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_BS11 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_BS11 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_BS11.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_WT11 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_WT11 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_WT11.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_HLP11 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_HLP11 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_HLP11.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_HLPA11 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_HLPA11 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_HLPA11.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_BS12 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_BS12 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_BS12.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_WT12 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_WT12 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_WT12.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_HLP12 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_HLP12 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_HLP12.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_HLPA12 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_WTAKP-WT_HLPA12 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WTAKP-WT_HLPA12.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_WTAKP_STR,
MANDT TYPE STRING,
BUKRS TYPE STRING,
LIFNR TYPE STRING,
WT_CALY TYPE STRING,
WITHT TYPE STRING,
WT_WITHCD TYPE STRING,
LAUFD TYPE STRING,
LAUFI TYPE STRING,
WT_BS01 TYPE STRING,
WT_WT01 TYPE STRING,
WT_HLP01 TYPE STRING,
WT_HLPA01 TYPE STRING,
WT_BS02 TYPE STRING,
WT_WT02 TYPE STRING,
WT_HLP02 TYPE STRING,
WT_HLPA02 TYPE STRING,
WT_BS03 TYPE STRING,
WT_WT03 TYPE STRING,
WT_HLP03 TYPE STRING,
WT_HLPA03 TYPE STRING,
WT_BS04 TYPE STRING,
WT_WT04 TYPE STRING,
WT_HLP04 TYPE STRING,
WT_HLPA04 TYPE STRING,
WT_BS05 TYPE STRING,
WT_WT05 TYPE STRING,
WT_HLP05 TYPE STRING,
WT_HLPA05 TYPE STRING,
WT_BS06 TYPE STRING,
WT_WT06 TYPE STRING,
WT_HLP06 TYPE STRING,
WT_HLPA06 TYPE STRING,
WT_BS07 TYPE STRING,
WT_WT07 TYPE STRING,
WT_HLP07 TYPE STRING,
WT_HLPA07 TYPE STRING,
WT_BS08 TYPE STRING,
WT_WT08 TYPE STRING,
WT_HLP08 TYPE STRING,
WT_HLPA08 TYPE STRING,
WT_BS09 TYPE STRING,
WT_WT09 TYPE STRING,
WT_HLP09 TYPE STRING,
WT_HLPA09 TYPE STRING,
WT_BS10 TYPE STRING,
WT_WT10 TYPE STRING,
WT_HLP10 TYPE STRING,
WT_HLPA10 TYPE STRING,
WT_BS11 TYPE STRING,
WT_WT11 TYPE STRING,
WT_HLP11 TYPE STRING,
WT_HLPA11 TYPE STRING,
WT_BS12 TYPE STRING,
WT_WT12 TYPE STRING,
WT_HLP12 TYPE STRING,
WT_HLPA12 TYPE STRING,END OF T_EKKO_STR. DATA: WA_WTAKP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_WTAKP_STR-MANDT sy-vline
WA_WTAKP_STR-BUKRS sy-vline
WA_WTAKP_STR-LIFNR sy-vline
WA_WTAKP_STR-WT_CALY sy-vline
WA_WTAKP_STR-WITHT sy-vline
WA_WTAKP_STR-WT_WITHCD sy-vline
WA_WTAKP_STR-LAUFD sy-vline
WA_WTAKP_STR-LAUFI sy-vline
WA_WTAKP_STR-WT_BS01 sy-vline
WA_WTAKP_STR-WT_WT01 sy-vline
WA_WTAKP_STR-WT_HLP01 sy-vline
WA_WTAKP_STR-WT_HLPA01 sy-vline
WA_WTAKP_STR-WT_BS02 sy-vline
WA_WTAKP_STR-WT_WT02 sy-vline
WA_WTAKP_STR-WT_HLP02 sy-vline
WA_WTAKP_STR-WT_HLPA02 sy-vline
WA_WTAKP_STR-WT_BS03 sy-vline
WA_WTAKP_STR-WT_WT03 sy-vline
WA_WTAKP_STR-WT_HLP03 sy-vline
WA_WTAKP_STR-WT_HLPA03 sy-vline
WA_WTAKP_STR-WT_BS04 sy-vline
WA_WTAKP_STR-WT_WT04 sy-vline
WA_WTAKP_STR-WT_HLP04 sy-vline
WA_WTAKP_STR-WT_HLPA04 sy-vline
WA_WTAKP_STR-WT_BS05 sy-vline
WA_WTAKP_STR-WT_WT05 sy-vline
WA_WTAKP_STR-WT_HLP05 sy-vline
WA_WTAKP_STR-WT_HLPA05 sy-vline
WA_WTAKP_STR-WT_BS06 sy-vline
WA_WTAKP_STR-WT_WT06 sy-vline
WA_WTAKP_STR-WT_HLP06 sy-vline
WA_WTAKP_STR-WT_HLPA06 sy-vline
WA_WTAKP_STR-WT_BS07 sy-vline
WA_WTAKP_STR-WT_WT07 sy-vline
WA_WTAKP_STR-WT_HLP07 sy-vline
WA_WTAKP_STR-WT_HLPA07 sy-vline
WA_WTAKP_STR-WT_BS08 sy-vline
WA_WTAKP_STR-WT_WT08 sy-vline
WA_WTAKP_STR-WT_HLP08 sy-vline
WA_WTAKP_STR-WT_HLPA08 sy-vline
WA_WTAKP_STR-WT_BS09 sy-vline
WA_WTAKP_STR-WT_WT09 sy-vline
WA_WTAKP_STR-WT_HLP09 sy-vline
WA_WTAKP_STR-WT_HLPA09 sy-vline
WA_WTAKP_STR-WT_BS10 sy-vline
WA_WTAKP_STR-WT_WT10 sy-vline
WA_WTAKP_STR-WT_HLP10 sy-vline
WA_WTAKP_STR-WT_HLPA10 sy-vline
WA_WTAKP_STR-WT_BS11 sy-vline
WA_WTAKP_STR-WT_WT11 sy-vline
WA_WTAKP_STR-WT_HLP11 sy-vline
WA_WTAKP_STR-WT_HLPA11 sy-vline
WA_WTAKP_STR-WT_BS12 sy-vline
WA_WTAKP_STR-WT_WT12 sy-vline
WA_WTAKP_STR-WT_HLP12 sy-vline
WA_WTAKP_STR-WT_HLPA12 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.