ABAP Select data from SAP table WSGET_MEMORY_RESPONSE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP WSGET_MEMORY_RESPONSE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to WSGET_MEMORY_RESPONSE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the WSGET_MEMORY_RESPONSE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_WSGET_MEMORY_RESPONSE TYPE STANDARD TABLE OF WSGET_MEMORY_RESPONSE,
      WA_WSGET_MEMORY_RESPONSE TYPE WSGET_MEMORY_RESPONSE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <WSGET_MEMORY_RESPONSE> TYPE WSGET_MEMORY_RESPONSE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_WSGET_MEMORY_RESPONSE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM WSGET_MEMORY_RESPONSE
  INTO TABLE IT_WSGET_MEMORY_RESPONSE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM WSGET_MEMORY_RESPONSE
*  INTO TABLE @DATA(IT_WSGET_MEMORY_RESPONSE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_WSGET_MEMORY_RESPONSE INDEX 1 INTO DATA(WA_WSGET_MEMORY_RESPONSE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_WSGET_MEMORY_RESPONSE ASSIGNING <WSGET_MEMORY_RESPONSE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<WSGET_MEMORY_RESPONSE>-CONTROLLER = 1.
<WSGET_MEMORY_RESPONSE>-RESULT = 1.
<WSGET_MEMORY_RESPONSE>-CONTROLLER = 1.
<WSGET_MEMORY_RESPONSE>-COLLECTION_TIME = 1.
<WSGET_MEMORY_RESPONSE>-IDENTIFIER = 1.
ENDLOOP.

LOOP AT IT_WSGET_MEMORY_RESPONSE INTO WA_WSGET_MEMORY_RESPONSE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_WSGET_MEMORY_RESPONSE-NUMBER_OF_PAGES_IN, sy-vline,
WA_WSGET_MEMORY_RESPONSE-NUMBER_OF_PAGES_OUT, sy-vline,
WA_WSGET_MEMORY_RESPONSE-DATA_PAGED_IN, sy-vline,
WA_WSGET_MEMORY_RESPONSE-DATA_PAGED_OUT, sy-vline,
WA_WSGET_MEMORY_RESPONSE-FREE_MEMORY, sy-vline,
WA_WSGET_MEMORY_RESPONSE-PHYS_MEMORY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_WSGET_MEMORY_RESPONSE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_WSGET_MEMORY_RESPONSE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_WSGET_MEMORY_RESPONSE INTO WA_WSGET_MEMORY_RESPONSE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_WSGET_MEMORY_RESPONSE_STR,
CONTROLLER TYPE STRING,
RESULT TYPE STRING,
CONTROLLER TYPE STRING,
COLLECTION_TIME TYPE STRING,
IDENTIFIER TYPE STRING,
NUMBER_OF_PAGES_IN TYPE STRING,
NUMBER_OF_PAGES_OUT TYPE STRING,
DATA_PAGED_IN TYPE STRING,
DATA_PAGED_OUT TYPE STRING,
FREE_MEMORY TYPE STRING,
PHYS_MEMORY TYPE STRING,
CONFIGURED_SWAP TYPE STRING,
FREE_SWAP TYPE STRING,
SWAP_SIZE TYPE STRING,
MAX_SWAP_SIZE TYPE STRING,
FREE_MEM_INCL_FS_CACHE TYPE STRING,END OF T_EKKO_STR. DATA: WA_WSGET_MEMORY_RESPONSE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_WSGET_MEMORY_RESPONSE_STR-CONTROLLER sy-vline
WA_WSGET_MEMORY_RESPONSE_STR-RESULT sy-vline
WA_WSGET_MEMORY_RESPONSE_STR-CONTROLLER sy-vline
WA_WSGET_MEMORY_RESPONSE_STR-COLLECTION_TIME sy-vline
WA_WSGET_MEMORY_RESPONSE_STR-IDENTIFIER sy-vline
WA_WSGET_MEMORY_RESPONSE_STR-NUMBER_OF_PAGES_IN sy-vline
WA_WSGET_MEMORY_RESPONSE_STR-NUMBER_OF_PAGES_OUT sy-vline
WA_WSGET_MEMORY_RESPONSE_STR-DATA_PAGED_IN sy-vline
WA_WSGET_MEMORY_RESPONSE_STR-DATA_PAGED_OUT sy-vline
WA_WSGET_MEMORY_RESPONSE_STR-FREE_MEMORY sy-vline
WA_WSGET_MEMORY_RESPONSE_STR-PHYS_MEMORY sy-vline
WA_WSGET_MEMORY_RESPONSE_STR-CONFIGURED_SWAP sy-vline
WA_WSGET_MEMORY_RESPONSE_STR-FREE_SWAP sy-vline
WA_WSGET_MEMORY_RESPONSE_STR-SWAP_SIZE sy-vline
WA_WSGET_MEMORY_RESPONSE_STR-MAX_SWAP_SIZE sy-vline
WA_WSGET_MEMORY_RESPONSE_STR-FREE_MEM_INCL_FS_CACHE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.