ABAP Select data from SAP table WSAM_PLNT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP WSAM_PLNT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to WSAM_PLNT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the WSAM_PLNT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_WSAM_PLNT TYPE STANDARD TABLE OF WSAM_PLNT,
      WA_WSAM_PLNT TYPE WSAM_PLNT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <WSAM_PLNT> TYPE WSAM_PLNT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_WSAM_PLNT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM WSAM_PLNT
  INTO TABLE IT_WSAM_PLNT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM WSAM_PLNT
*  INTO TABLE @DATA(IT_WSAM_PLNT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_WSAM_PLNT INDEX 1 INTO DATA(WA_WSAM_PLNT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_WSAM_PLNT ASSIGNING <WSAM_PLNT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<WSAM_PLNT>-PLANT = 1.
<WSAM_PLNT>-MRP_TYPE = 1.
<WSAM_PLNT>-MRP_TYPE_D = 1.
<WSAM_PLNT>-REORDER_PT = 1.
<WSAM_PLNT>-REORDER_PT_C = 1.
ENDLOOP.

LOOP AT IT_WSAM_PLNT INTO WA_WSAM_PLNT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_WSAM_PLNT-SAFETY_STK, sy-vline,
WA_WSAM_PLNT-SAFETY_STK_C, sy-vline,
WA_WSAM_PLNT-MAX_STOCK, sy-vline,
WA_WSAM_PLNT-MAX_STOCK_C, sy-vline,
WA_WSAM_PLNT-BASE_UOM, sy-vline,
WA_WSAM_PLNT-STOCK, sy-vline.
ENDLOOP. *Add any further fields from structure WA_WSAM_PLNT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_WSAM_PLNT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_WSAM_PLNT INTO WA_WSAM_PLNT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field BASE_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_WSAM_PLNT-BASE_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WSAM_PLNT-BASE_UOM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_WSAM_PLNT_STR,
PLANT TYPE STRING,
MRP_TYPE TYPE STRING,
MRP_TYPE_D TYPE STRING,
REORDER_PT TYPE STRING,
REORDER_PT_C TYPE STRING,
SAFETY_STK TYPE STRING,
SAFETY_STK_C TYPE STRING,
MAX_STOCK TYPE STRING,
MAX_STOCK_C TYPE STRING,
BASE_UOM TYPE STRING,
STOCK TYPE STRING,
LOTSIZEKEY TYPE STRING,
MRPPROFILE TYPE STRING,
DUMMY_FIELD TYPE STRING,END OF T_EKKO_STR. DATA: WA_WSAM_PLNT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_WSAM_PLNT_STR-PLANT sy-vline
WA_WSAM_PLNT_STR-MRP_TYPE sy-vline
WA_WSAM_PLNT_STR-MRP_TYPE_D sy-vline
WA_WSAM_PLNT_STR-REORDER_PT sy-vline
WA_WSAM_PLNT_STR-REORDER_PT_C sy-vline
WA_WSAM_PLNT_STR-SAFETY_STK sy-vline
WA_WSAM_PLNT_STR-SAFETY_STK_C sy-vline
WA_WSAM_PLNT_STR-MAX_STOCK sy-vline
WA_WSAM_PLNT_STR-MAX_STOCK_C sy-vline
WA_WSAM_PLNT_STR-BASE_UOM sy-vline
WA_WSAM_PLNT_STR-STOCK sy-vline
WA_WSAM_PLNT_STR-LOTSIZEKEY sy-vline
WA_WSAM_PLNT_STR-MRPPROFILE sy-vline
WA_WSAM_PLNT_STR-DUMMY_FIELD sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.