ABAP Select data from SAP table WRMA_S_COMPCODE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP WRMA_S_COMPCODE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to WRMA_S_COMPCODE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the WRMA_S_COMPCODE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_WRMA_S_COMPCODE TYPE STANDARD TABLE OF WRMA_S_COMPCODE,
      WA_WRMA_S_COMPCODE TYPE WRMA_S_COMPCODE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <WRMA_S_COMPCODE> TYPE WRMA_S_COMPCODE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_WRMA_S_COMPCODE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM WRMA_S_COMPCODE
  INTO TABLE IT_WRMA_S_COMPCODE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM WRMA_S_COMPCODE
*  INTO TABLE @DATA(IT_WRMA_S_COMPCODE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_WRMA_S_COMPCODE INDEX 1 INTO DATA(WA_WRMA_S_COMPCODE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_WRMA_S_COMPCODE ASSIGNING <WRMA_S_COMPCODE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<WRMA_S_COMPCODE>-PROF = 1.
<WRMA_S_COMPCODE>-COMP_CODE = 1.
<WRMA_S_COMPCODE>-OBJECTMODEL = 1.
<WRMA_S_COMPCODE>-OBJECTLEVEL = 1.
<WRMA_S_COMPCODE>-NRNR = 1.
ENDLOOP.

LOOP AT IT_WRMA_S_COMPCODE INTO WA_WRMA_S_COMPCODE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_WRMA_S_COMPCODE-ALTFISCV1, sy-vline,
WA_WRMA_S_COMPCODE-ALTFISCV2, sy-vline,
WA_WRMA_S_COMPCODE-DELFPER, sy-vline,
WA_WRMA_S_COMPCODE-DISTR_PROFILE, sy-vline,
ENDLOOP. *Add any further fields from structure WA_WRMA_S_COMPCODE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_WRMA_S_COMPCODE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_WRMA_S_COMPCODE INTO WA_WRMA_S_COMPCODE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit PERI7, internal->external for field DELFPER CALL FUNCTION 'CONVERSION_EXIT_PERI7_OUTPUT' EXPORTING input = WA_WRMA_S_COMPCODE-DELFPER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WRMA_S_COMPCODE-DELFPER.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_WRMA_S_COMPCODE_STR,
PROF TYPE STRING,
COMP_CODE TYPE STRING,
OBJECTMODEL TYPE STRING,
OBJECTLEVEL TYPE STRING,
NRNR TYPE STRING,
ALTFISCV1 TYPE STRING,
ALTFISCV2 TYPE STRING,
DELFPER TYPE STRING,
DISTR_PROFILE TYPE STRING,END OF T_EKKO_STR. DATA: WA_WRMA_S_COMPCODE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_WRMA_S_COMPCODE_STR-PROF sy-vline
WA_WRMA_S_COMPCODE_STR-COMP_CODE sy-vline
WA_WRMA_S_COMPCODE_STR-OBJECTMODEL sy-vline
WA_WRMA_S_COMPCODE_STR-OBJECTLEVEL sy-vline
WA_WRMA_S_COMPCODE_STR-NRNR sy-vline
WA_WRMA_S_COMPCODE_STR-ALTFISCV1 sy-vline
WA_WRMA_S_COMPCODE_STR-ALTFISCV2 sy-vline
WA_WRMA_S_COMPCODE_STR-DELFPER sy-vline
WA_WRMA_S_COMPCODE_STR-DISTR_PROFILE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.