ABAP Select data from SAP table WRFT_BUDG_LEV into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP WRFT_BUDG_LEV table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to WRFT_BUDG_LEV. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the WRFT_BUDG_LEV table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_WRFT_BUDG_LEV TYPE STANDARD TABLE OF WRFT_BUDG_LEV,
      WA_WRFT_BUDG_LEV TYPE WRFT_BUDG_LEV,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <WRFT_BUDG_LEV> TYPE WRFT_BUDG_LEV.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_WRFT_BUDG_LEV.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM WRFT_BUDG_LEV
  INTO TABLE IT_WRFT_BUDG_LEV.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM WRFT_BUDG_LEV
*  INTO TABLE @DATA(IT_WRFT_BUDG_LEV2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_WRFT_BUDG_LEV INDEX 1 INTO DATA(WA_WRFT_BUDG_LEV2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_WRFT_BUDG_LEV ASSIGNING <WRFT_BUDG_LEV>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<WRFT_BUDG_LEV>-MANDT = 1.
<WRFT_BUDG_LEV>-BUDG_LEVEL = 1.
<WRFT_BUDG_LEV>-CHANM = 1.
<WRFT_BUDG_LEV>-DATATP = 1.
<WRFT_BUDG_LEV>-INTLEN = 1.
ENDLOOP.

LOOP AT IT_WRFT_BUDG_LEV INTO WA_WRFT_BUDG_LEV.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_WRFT_BUDG_LEV-IOBJTP, sy-vline,
WA_WRFT_BUDG_LEV-FIELD, sy-vline,
WA_WRFT_BUDG_LEV-TAB_NAME, sy-vline,
WA_WRFT_BUDG_LEV-BADI_IMPL, sy-vline,
WA_WRFT_BUDG_LEV-HIERARCHY, sy-vline,
WA_WRFT_BUDG_LEV-HIEID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_WRFT_BUDG_LEV you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_WRFT_BUDG_LEV TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_WRFT_BUDG_LEV INTO WA_WRFT_BUDG_LEV. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit DTYPE, internal->external for field DATATP CALL FUNCTION 'CONVERSION_EXIT_DTYPE_OUTPUT' EXPORTING input = WA_WRFT_BUDG_LEV-DATATP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WRFT_BUDG_LEV-DATATP.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_WRFT_BUDG_LEV_STR,
MANDT TYPE STRING,
BUDG_LEVEL TYPE STRING,
CHANM TYPE STRING,
DATATP TYPE STRING,
INTLEN TYPE STRING,
IOBJTP TYPE STRING,
FIELD TYPE STRING,
TAB_NAME TYPE STRING,
BADI_IMPL TYPE STRING,
HIERARCHY TYPE STRING,
HIEID TYPE STRING,
LEVEL_AH TYPE STRING,
LEVEL_MC TYPE STRING,
PERIV TYPE STRING,
POSITION_ODS TYPE STRING,END OF T_EKKO_STR. DATA: WA_WRFT_BUDG_LEV_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_WRFT_BUDG_LEV_STR-MANDT sy-vline
WA_WRFT_BUDG_LEV_STR-BUDG_LEVEL sy-vline
WA_WRFT_BUDG_LEV_STR-CHANM sy-vline
WA_WRFT_BUDG_LEV_STR-DATATP sy-vline
WA_WRFT_BUDG_LEV_STR-INTLEN sy-vline
WA_WRFT_BUDG_LEV_STR-IOBJTP sy-vline
WA_WRFT_BUDG_LEV_STR-FIELD sy-vline
WA_WRFT_BUDG_LEV_STR-TAB_NAME sy-vline
WA_WRFT_BUDG_LEV_STR-BADI_IMPL sy-vline
WA_WRFT_BUDG_LEV_STR-HIERARCHY sy-vline
WA_WRFT_BUDG_LEV_STR-HIEID sy-vline
WA_WRFT_BUDG_LEV_STR-LEVEL_AH sy-vline
WA_WRFT_BUDG_LEV_STR-LEVEL_MC sy-vline
WA_WRFT_BUDG_LEV_STR-PERIV sy-vline
WA_WRFT_BUDG_LEV_STR-POSITION_ODS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.