ABAP Select data from SAP table WRF_SIT_KNVV into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP WRF_SIT_KNVV table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to WRF_SIT_KNVV. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the WRF_SIT_KNVV table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_WRF_SIT_KNVV TYPE STANDARD TABLE OF WRF_SIT_KNVV,
      WA_WRF_SIT_KNVV TYPE WRF_SIT_KNVV,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <WRF_SIT_KNVV> TYPE WRF_SIT_KNVV.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_WRF_SIT_KNVV.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM WRF_SIT_KNVV
  INTO TABLE IT_WRF_SIT_KNVV.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM WRF_SIT_KNVV
*  INTO TABLE @DATA(IT_WRF_SIT_KNVV2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_WRF_SIT_KNVV INDEX 1 INTO DATA(WA_WRF_SIT_KNVV2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_WRF_SIT_KNVV ASSIGNING <WRF_SIT_KNVV>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<WRF_SIT_KNVV>-MANDT = 1.
<WRF_SIT_KNVV>-KUNNR = 1.
<WRF_SIT_KNVV>-VKORG = 1.
<WRF_SIT_KNVV>-VTWEG = 1.
<WRF_SIT_KNVV>-SPART = 1.
ENDLOOP.

LOOP AT IT_WRF_SIT_KNVV INTO WA_WRF_SIT_KNVV.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_WRF_SIT_KNVV-ERNAM, sy-vline,
WA_WRF_SIT_KNVV-ERDAT, sy-vline,
WA_WRF_SIT_KNVV-BEGRU, sy-vline,
WA_WRF_SIT_KNVV-LOEVM, sy-vline,
WA_WRF_SIT_KNVV-VERSG, sy-vline,
WA_WRF_SIT_KNVV-AUFSD, sy-vline.
ENDLOOP. *Add any further fields from structure WA_WRF_SIT_KNVV you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_WRF_SIT_KNVV TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_WRF_SIT_KNVV INTO WA_WRF_SIT_KNVV. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field KUNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WRF_SIT_KNVV-KUNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WRF_SIT_KNVV-KUNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VSORT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WRF_SIT_KNVV-VSORT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WRF_SIT_KNVV-VSORT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTRG, internal->external for field PODTG CALL FUNCTION 'CONVERSION_EXIT_TSTRG_OUTPUT' EXPORTING input = WA_WRF_SIT_KNVV-PODTG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WRF_SIT_KNVV-PODTG.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_WRF_SIT_KNVV_STR,
MANDT TYPE STRING,
KUNNR TYPE STRING,
VKORG TYPE STRING,
VTWEG TYPE STRING,
SPART TYPE STRING,
ERNAM TYPE STRING,
ERDAT TYPE STRING,
BEGRU TYPE STRING,
LOEVM TYPE STRING,
VERSG TYPE STRING,
AUFSD TYPE STRING,
KALKS TYPE STRING,
KDGRP TYPE STRING,
BZIRK TYPE STRING,
KONDA TYPE STRING,
PLTYP TYPE STRING,
AWAHR TYPE STRING,
INCO1 TYPE STRING,
INCO2 TYPE STRING,
LIFSD TYPE STRING,
AUTLF TYPE STRING,
ANTLF TYPE STRING,
KZTLF TYPE STRING,
KZAZU TYPE STRING,
CHSPL TYPE STRING,
LPRIO TYPE STRING,
EIKTO TYPE STRING,
VSBED TYPE STRING,
FAKSD TYPE STRING,
MRNKZ TYPE STRING,
PERFK TYPE STRING,
PERRL TYPE STRING,
KVAKZ TYPE STRING,
KVAWT TYPE STRING,
WAERS TYPE STRING,
KLABC TYPE STRING,
KTGRD TYPE STRING,
ZTERM TYPE STRING,
VWERK TYPE STRING,
VKGRP TYPE STRING,
VKBUR TYPE STRING,
VSORT TYPE STRING,
KVGR1 TYPE STRING,
KVGR2 TYPE STRING,
KVGR3 TYPE STRING,
KVGR4 TYPE STRING,
KVGR5 TYPE STRING,
BOKRE TYPE STRING,
BOIDT TYPE STRING,
KURST TYPE STRING,
PRFRE TYPE STRING,
PRAT1 TYPE STRING,
PRAT2 TYPE STRING,
PRAT3 TYPE STRING,
PRAT4 TYPE STRING,
PRAT5 TYPE STRING,
PRAT6 TYPE STRING,
PRAT7 TYPE STRING,
PRAT8 TYPE STRING,
PRAT9 TYPE STRING,
PRATA TYPE STRING,
KABSS TYPE STRING,
KKBER TYPE STRING,
CASSD TYPE STRING,
RDOFF TYPE STRING,
AGREL TYPE STRING,
MEGRU TYPE STRING,
UEBTO TYPE STRING,
UNTTO TYPE STRING,
UEBTK TYPE STRING,
PVKSM TYPE STRING,
PODKZ TYPE STRING,
PODTG TYPE STRING,END OF T_EKKO_STR. DATA: WA_WRF_SIT_KNVV_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_WRF_SIT_KNVV_STR-MANDT sy-vline
WA_WRF_SIT_KNVV_STR-KUNNR sy-vline
WA_WRF_SIT_KNVV_STR-VKORG sy-vline
WA_WRF_SIT_KNVV_STR-VTWEG sy-vline
WA_WRF_SIT_KNVV_STR-SPART sy-vline
WA_WRF_SIT_KNVV_STR-ERNAM sy-vline
WA_WRF_SIT_KNVV_STR-ERDAT sy-vline
WA_WRF_SIT_KNVV_STR-BEGRU sy-vline
WA_WRF_SIT_KNVV_STR-LOEVM sy-vline
WA_WRF_SIT_KNVV_STR-VERSG sy-vline
WA_WRF_SIT_KNVV_STR-AUFSD sy-vline
WA_WRF_SIT_KNVV_STR-KALKS sy-vline
WA_WRF_SIT_KNVV_STR-KDGRP sy-vline
WA_WRF_SIT_KNVV_STR-BZIRK sy-vline
WA_WRF_SIT_KNVV_STR-KONDA sy-vline
WA_WRF_SIT_KNVV_STR-PLTYP sy-vline
WA_WRF_SIT_KNVV_STR-AWAHR sy-vline
WA_WRF_SIT_KNVV_STR-INCO1 sy-vline
WA_WRF_SIT_KNVV_STR-INCO2 sy-vline
WA_WRF_SIT_KNVV_STR-LIFSD sy-vline
WA_WRF_SIT_KNVV_STR-AUTLF sy-vline
WA_WRF_SIT_KNVV_STR-ANTLF sy-vline
WA_WRF_SIT_KNVV_STR-KZTLF sy-vline
WA_WRF_SIT_KNVV_STR-KZAZU sy-vline
WA_WRF_SIT_KNVV_STR-CHSPL sy-vline
WA_WRF_SIT_KNVV_STR-LPRIO sy-vline
WA_WRF_SIT_KNVV_STR-EIKTO sy-vline
WA_WRF_SIT_KNVV_STR-VSBED sy-vline
WA_WRF_SIT_KNVV_STR-FAKSD sy-vline
WA_WRF_SIT_KNVV_STR-MRNKZ sy-vline
WA_WRF_SIT_KNVV_STR-PERFK sy-vline
WA_WRF_SIT_KNVV_STR-PERRL sy-vline
WA_WRF_SIT_KNVV_STR-KVAKZ sy-vline
WA_WRF_SIT_KNVV_STR-KVAWT sy-vline
WA_WRF_SIT_KNVV_STR-WAERS sy-vline
WA_WRF_SIT_KNVV_STR-KLABC sy-vline
WA_WRF_SIT_KNVV_STR-KTGRD sy-vline
WA_WRF_SIT_KNVV_STR-ZTERM sy-vline
WA_WRF_SIT_KNVV_STR-VWERK sy-vline
WA_WRF_SIT_KNVV_STR-VKGRP sy-vline
WA_WRF_SIT_KNVV_STR-VKBUR sy-vline
WA_WRF_SIT_KNVV_STR-VSORT sy-vline
WA_WRF_SIT_KNVV_STR-KVGR1 sy-vline
WA_WRF_SIT_KNVV_STR-KVGR2 sy-vline
WA_WRF_SIT_KNVV_STR-KVGR3 sy-vline
WA_WRF_SIT_KNVV_STR-KVGR4 sy-vline
WA_WRF_SIT_KNVV_STR-KVGR5 sy-vline
WA_WRF_SIT_KNVV_STR-BOKRE sy-vline
WA_WRF_SIT_KNVV_STR-BOIDT sy-vline
WA_WRF_SIT_KNVV_STR-KURST sy-vline
WA_WRF_SIT_KNVV_STR-PRFRE sy-vline
WA_WRF_SIT_KNVV_STR-PRAT1 sy-vline
WA_WRF_SIT_KNVV_STR-PRAT2 sy-vline
WA_WRF_SIT_KNVV_STR-PRAT3 sy-vline
WA_WRF_SIT_KNVV_STR-PRAT4 sy-vline
WA_WRF_SIT_KNVV_STR-PRAT5 sy-vline
WA_WRF_SIT_KNVV_STR-PRAT6 sy-vline
WA_WRF_SIT_KNVV_STR-PRAT7 sy-vline
WA_WRF_SIT_KNVV_STR-PRAT8 sy-vline
WA_WRF_SIT_KNVV_STR-PRAT9 sy-vline
WA_WRF_SIT_KNVV_STR-PRATA sy-vline
WA_WRF_SIT_KNVV_STR-KABSS sy-vline
WA_WRF_SIT_KNVV_STR-KKBER sy-vline
WA_WRF_SIT_KNVV_STR-CASSD sy-vline
WA_WRF_SIT_KNVV_STR-RDOFF sy-vline
WA_WRF_SIT_KNVV_STR-AGREL sy-vline
WA_WRF_SIT_KNVV_STR-MEGRU sy-vline
WA_WRF_SIT_KNVV_STR-UEBTO sy-vline
WA_WRF_SIT_KNVV_STR-UNTTO sy-vline
WA_WRF_SIT_KNVV_STR-UEBTK sy-vline
WA_WRF_SIT_KNVV_STR-PVKSM sy-vline
WA_WRF_SIT_KNVV_STR-PODKZ sy-vline
WA_WRF_SIT_KNVV_STR-PODTG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.