ABAP Select data from SAP table WRF_PPW_PPDCALCITEMCTRL_STY into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP WRF_PPW_PPDCALCITEMCTRL_STY table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to WRF_PPW_PPDCALCITEMCTRL_STY. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the WRF_PPW_PPDCALCITEMCTRL_STY table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_WRF_PPW_PPDCALCITEMCTRL_STY TYPE STANDARD TABLE OF WRF_PPW_PPDCALCITEMCTRL_STY,
      WA_WRF_PPW_PPDCALCITEMCTRL_STY TYPE WRF_PPW_PPDCALCITEMCTRL_STY,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <WRF_PPW_PPDCALCITEMCTRL_STY> TYPE WRF_PPW_PPDCALCITEMCTRL_STY.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_WRF_PPW_PPDCALCITEMCTRL_STY.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM WRF_PPW_PPDCALCITEMCTRL_STY
  INTO TABLE IT_WRF_PPW_PPDCALCITEMCTRL_STY.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM WRF_PPW_PPDCALCITEMCTRL_STY
*  INTO TABLE @DATA(IT_WRF_PPW_PPDCALCITEMCTRL_STY2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_WRF_PPW_PPDCALCITEMCTRL_STY INDEX 1 INTO DATA(WA_WRF_PPW_PPDCALCITEMCTRL_STY2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_WRF_PPW_PPDCALCITEMCTRL_STY ASSIGNING <WRF_PPW_PPDCALCITEMCTRL_STY>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<WRF_PPW_PPDCALCITEMCTRL_STY>-GUID_CALC = 1.
<WRF_PPW_PPDCALCITEMCTRL_STY>-PARENT = 1.
<WRF_PPW_PPDCALCITEMCTRL_STY>-MATNR = 1.
<WRF_PPW_PPDCALCITEMCTRL_STY>-VRKME = 1.
<WRF_PPW_PPDCALCITEMCTRL_STY>-EAN11 = 1.
ENDLOOP.

LOOP AT IT_WRF_PPW_PPDCALCITEMCTRL_STY INTO WA_WRF_PPW_PPDCALCITEMCTRL_STY.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_WRF_PPW_PPDCALCITEMCTRL_STY-VKORG, sy-vline,
WA_WRF_PPW_PPDCALCITEMCTRL_STY-VTWEG, sy-vline,
WA_WRF_PPW_PPDCALCITEMCTRL_STY-WERKS, sy-vline,
WA_WRF_PPW_PPDCALCITEMCTRL_STY-PLTYP, sy-vline,
WA_WRF_PPW_PPDCALCITEMCTRL_STY-BGINT, sy-vline,
WA_WRF_PPW_PPDCALCITEMCTRL_STY-VKKAB, sy-vline.
ENDLOOP. *Add any further fields from structure WA_WRF_PPW_PPDCALCITEMCTRL_STY you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_WRF_PPW_PPDCALCITEMCTRL_STY TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_WRF_PPW_PPDCALCITEMCTRL_STY INTO WA_WRF_PPW_PPDCALCITEMCTRL_STY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_WRF_PPW_PPDCALCITEMCTRL_STY-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WRF_PPW_PPDCALCITEMCTRL_STY-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VRKME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_WRF_PPW_PPDCALCITEMCTRL_STY-VRKME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WRF_PPW_PPDCALCITEMCTRL_STY-VRKME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EAN11, internal->external for field EAN11 CALL FUNCTION 'CONVERSION_EXIT_EAN11_OUTPUT' EXPORTING input = WA_WRF_PPW_PPDCALCITEMCTRL_STY-EAN11 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WRF_PPW_PPDCALCITEMCTRL_STY-EAN11.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WRF_PPW_PPDCALCITEMCTRL_STY-KBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WRF_PPW_PPDCALCITEMCTRL_STY-KBELN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KBELN_INIT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WRF_PPW_PPDCALCITEMCTRL_STY-KBELN_INIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WRF_PPW_PPDCALCITEMCTRL_STY-KBELN_INIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KBELN_COPY CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WRF_PPW_PPDCALCITEMCTRL_STY-KBELN_COPY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WRF_PPW_PPDCALCITEMCTRL_STY-KBELN_COPY.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_WRF_PPW_PPDCALCITEMCTRL_STY_STR,
GUID_CALC TYPE STRING,
PARENT TYPE STRING,
MATNR TYPE STRING,
VRKME TYPE STRING,
EAN11 TYPE STRING,
VKORG TYPE STRING,
VTWEG TYPE STRING,
WERKS TYPE STRING,
PLTYP TYPE STRING,
BGINT TYPE STRING,
VKKAB TYPE STRING,
VKKBI TYPE STRING,
KBELN TYPE STRING,
KBELP TYPE STRING,
BPSTA TYPE STRING,
KBELN_INIT TYPE STRING,
KBELP_INIT TYPE STRING,
VKKAB_INIT TYPE STRING,
VKKBI_INIT TYPE STRING,
BPSTA_INIT TYPE STRING,
KBELN_COPY TYPE STRING,
KBELP_COPY TYPE STRING,
VKKAB_OLD TYPE STRING,
VKKBI_OLD TYPE STRING,
FCODE TYPE STRING,
DOCEX TYPE STRING,
DOCRD TYPE STRING,
TRCAL TYPE STRING,
RECAL TYPE STRING,
SAVED TYPE STRING,
NOEXP TYPE STRING,
UPDKZ TYPE STRING,END OF T_EKKO_STR. DATA: WA_WRF_PPW_PPDCALCITEMCTRL_STY_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_WRF_PPW_PPDCALCITEMCTRL_STY_STR-GUID_CALC sy-vline
WA_WRF_PPW_PPDCALCITEMCTRL_STY_STR-PARENT sy-vline
WA_WRF_PPW_PPDCALCITEMCTRL_STY_STR-MATNR sy-vline
WA_WRF_PPW_PPDCALCITEMCTRL_STY_STR-VRKME sy-vline
WA_WRF_PPW_PPDCALCITEMCTRL_STY_STR-EAN11 sy-vline
WA_WRF_PPW_PPDCALCITEMCTRL_STY_STR-VKORG sy-vline
WA_WRF_PPW_PPDCALCITEMCTRL_STY_STR-VTWEG sy-vline
WA_WRF_PPW_PPDCALCITEMCTRL_STY_STR-WERKS sy-vline
WA_WRF_PPW_PPDCALCITEMCTRL_STY_STR-PLTYP sy-vline
WA_WRF_PPW_PPDCALCITEMCTRL_STY_STR-BGINT sy-vline
WA_WRF_PPW_PPDCALCITEMCTRL_STY_STR-VKKAB sy-vline
WA_WRF_PPW_PPDCALCITEMCTRL_STY_STR-VKKBI sy-vline
WA_WRF_PPW_PPDCALCITEMCTRL_STY_STR-KBELN sy-vline
WA_WRF_PPW_PPDCALCITEMCTRL_STY_STR-KBELP sy-vline
WA_WRF_PPW_PPDCALCITEMCTRL_STY_STR-BPSTA sy-vline
WA_WRF_PPW_PPDCALCITEMCTRL_STY_STR-KBELN_INIT sy-vline
WA_WRF_PPW_PPDCALCITEMCTRL_STY_STR-KBELP_INIT sy-vline
WA_WRF_PPW_PPDCALCITEMCTRL_STY_STR-VKKAB_INIT sy-vline
WA_WRF_PPW_PPDCALCITEMCTRL_STY_STR-VKKBI_INIT sy-vline
WA_WRF_PPW_PPDCALCITEMCTRL_STY_STR-BPSTA_INIT sy-vline
WA_WRF_PPW_PPDCALCITEMCTRL_STY_STR-KBELN_COPY sy-vline
WA_WRF_PPW_PPDCALCITEMCTRL_STY_STR-KBELP_COPY sy-vline
WA_WRF_PPW_PPDCALCITEMCTRL_STY_STR-VKKAB_OLD sy-vline
WA_WRF_PPW_PPDCALCITEMCTRL_STY_STR-VKKBI_OLD sy-vline
WA_WRF_PPW_PPDCALCITEMCTRL_STY_STR-FCODE sy-vline
WA_WRF_PPW_PPDCALCITEMCTRL_STY_STR-DOCEX sy-vline
WA_WRF_PPW_PPDCALCITEMCTRL_STY_STR-DOCRD sy-vline
WA_WRF_PPW_PPDCALCITEMCTRL_STY_STR-TRCAL sy-vline
WA_WRF_PPW_PPDCALCITEMCTRL_STY_STR-RECAL sy-vline
WA_WRF_PPW_PPDCALCITEMCTRL_STY_STR-SAVED sy-vline
WA_WRF_PPW_PPDCALCITEMCTRL_STY_STR-NOEXP sy-vline
WA_WRF_PPW_PPDCALCITEMCTRL_STY_STR-UPDKZ sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.