ABAP Select data from SAP table WRF_PPW_BUSART_STY into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP WRF_PPW_BUSART_STY table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to WRF_PPW_BUSART_STY. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the WRF_PPW_BUSART_STY table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_WRF_PPW_BUSART_STY TYPE STANDARD TABLE OF WRF_PPW_BUSART_STY,
      WA_WRF_PPW_BUSART_STY TYPE WRF_PPW_BUSART_STY,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <WRF_PPW_BUSART_STY> TYPE WRF_PPW_BUSART_STY.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_WRF_PPW_BUSART_STY.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM WRF_PPW_BUSART_STY
  INTO TABLE IT_WRF_PPW_BUSART_STY.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM WRF_PPW_BUSART_STY
*  INTO TABLE @DATA(IT_WRF_PPW_BUSART_STY2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_WRF_PPW_BUSART_STY INDEX 1 INTO DATA(WA_WRF_PPW_BUSART_STY2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_WRF_PPW_BUSART_STY ASSIGNING <WRF_PPW_BUSART_STY>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<WRF_PPW_BUSART_STY>-K = 1.
<WRF_PPW_BUSART_STY>-MATNR = 1.
<WRF_PPW_BUSART_STY>-SATNR = 1.
<WRF_PPW_BUSART_STY>-HIER_ID = 1.
<WRF_PPW_BUSART_STY>-NODE01 = 1.
ENDLOOP.

LOOP AT IT_WRF_PPW_BUSART_STY INTO WA_WRF_PPW_BUSART_STY.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_WRF_PPW_BUSART_STY-NODE02, sy-vline,
WA_WRF_PPW_BUSART_STY-NODE03, sy-vline,
WA_WRF_PPW_BUSART_STY-NODE04, sy-vline,
WA_WRF_PPW_BUSART_STY-NODE05, sy-vline,
WA_WRF_PPW_BUSART_STY-NODE06, sy-vline,
WA_WRF_PPW_BUSART_STY-NODE07, sy-vline.
ENDLOOP. *Add any further fields from structure WA_WRF_PPW_BUSART_STY you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_WRF_PPW_BUSART_STY TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_WRF_PPW_BUSART_STY INTO WA_WRF_PPW_BUSART_STY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_WRF_PPW_BUSART_STY-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WRF_PPW_BUSART_STY-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field SATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_WRF_PPW_BUSART_STY-SATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WRF_PPW_BUSART_STY-SATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VRKME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_WRF_PPW_BUSART_STY-VRKME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WRF_PPW_BUSART_STY-VRKME.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_WRF_PPW_BUSART_STY_STR,
K TYPE STRING,
MATNR TYPE STRING,
SATNR TYPE STRING,
HIER_ID TYPE STRING,
NODE01 TYPE STRING,
NODE02 TYPE STRING,
NODE03 TYPE STRING,
NODE04 TYPE STRING,
NODE05 TYPE STRING,
NODE06 TYPE STRING,
NODE07 TYPE STRING,
NODE08 TYPE STRING,
NODE09 TYPE STRING,
NODE10 TYPE STRING,
NODE01_T TYPE STRING,
NODE02_T TYPE STRING,
NODE03_T TYPE STRING,
NODE04_T TYPE STRING,
NODE05_T TYPE STRING,
NODE06_T TYPE STRING,
NODE07_T TYPE STRING,
NODE08_T TYPE STRING,
NODE09_T TYPE STRING,
NODE10_T TYPE STRING,
MATKL TYPE STRING,
WGBEZ TYPE STRING,
VRKME TYPE STRING,
MAKTX TYPE STRING,
PPDART_GUID TYPE STRING,
VKORG TYPE STRING,
VTWEG TYPE STRING,
USRGRP TYPE STRING,
VKKAB_MDP TYPE STRING,
DISTCHAIN TYPE STRING,
BUDG_TYPE TYPE STRING,
T TYPE STRING,
MATNR_T TYPE STRING,
SATNR_T TYPE STRING,
HIER_ID_T TYPE STRING,
NODE01_T TYPE STRING,
NODE02_T TYPE STRING,
NODE03_T TYPE STRING,
NODE04_T TYPE STRING,
NODE05_T TYPE STRING,
NODE06_T TYPE STRING,
NODE07_T TYPE STRING,
NODE08_T TYPE STRING,
NODE09_T TYPE STRING,
NODE10_T TYPE STRING,
MATKL_T TYPE STRING,
VKORG_T TYPE STRING,
VTWEG_T TYPE STRING,
USRGRP_T TYPE STRING,
VKKAB_MDP_T TYPE STRING,
DISTCHAIN_T TYPE STRING,
BUDG_TYPE_T TYPE STRING,
RECID TYPE STRING,
STATUS TYPE STRING,
FILTER TYPE STRING,
CHANGED TYPE STRING,
DELETE_ON_SAVE TYPE STRING,END OF T_EKKO_STR. DATA: WA_WRF_PPW_BUSART_STY_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_WRF_PPW_BUSART_STY_STR-K sy-vline
WA_WRF_PPW_BUSART_STY_STR-MATNR sy-vline
WA_WRF_PPW_BUSART_STY_STR-SATNR sy-vline
WA_WRF_PPW_BUSART_STY_STR-HIER_ID sy-vline
WA_WRF_PPW_BUSART_STY_STR-NODE01 sy-vline
WA_WRF_PPW_BUSART_STY_STR-NODE02 sy-vline
WA_WRF_PPW_BUSART_STY_STR-NODE03 sy-vline
WA_WRF_PPW_BUSART_STY_STR-NODE04 sy-vline
WA_WRF_PPW_BUSART_STY_STR-NODE05 sy-vline
WA_WRF_PPW_BUSART_STY_STR-NODE06 sy-vline
WA_WRF_PPW_BUSART_STY_STR-NODE07 sy-vline
WA_WRF_PPW_BUSART_STY_STR-NODE08 sy-vline
WA_WRF_PPW_BUSART_STY_STR-NODE09 sy-vline
WA_WRF_PPW_BUSART_STY_STR-NODE10 sy-vline
WA_WRF_PPW_BUSART_STY_STR-NODE01_T sy-vline
WA_WRF_PPW_BUSART_STY_STR-NODE02_T sy-vline
WA_WRF_PPW_BUSART_STY_STR-NODE03_T sy-vline
WA_WRF_PPW_BUSART_STY_STR-NODE04_T sy-vline
WA_WRF_PPW_BUSART_STY_STR-NODE05_T sy-vline
WA_WRF_PPW_BUSART_STY_STR-NODE06_T sy-vline
WA_WRF_PPW_BUSART_STY_STR-NODE07_T sy-vline
WA_WRF_PPW_BUSART_STY_STR-NODE08_T sy-vline
WA_WRF_PPW_BUSART_STY_STR-NODE09_T sy-vline
WA_WRF_PPW_BUSART_STY_STR-NODE10_T sy-vline
WA_WRF_PPW_BUSART_STY_STR-MATKL sy-vline
WA_WRF_PPW_BUSART_STY_STR-WGBEZ sy-vline
WA_WRF_PPW_BUSART_STY_STR-VRKME sy-vline
WA_WRF_PPW_BUSART_STY_STR-MAKTX sy-vline
WA_WRF_PPW_BUSART_STY_STR-PPDART_GUID sy-vline
WA_WRF_PPW_BUSART_STY_STR-VKORG sy-vline
WA_WRF_PPW_BUSART_STY_STR-VTWEG sy-vline
WA_WRF_PPW_BUSART_STY_STR-USRGRP sy-vline
WA_WRF_PPW_BUSART_STY_STR-VKKAB_MDP sy-vline
WA_WRF_PPW_BUSART_STY_STR-DISTCHAIN sy-vline
WA_WRF_PPW_BUSART_STY_STR-BUDG_TYPE sy-vline
WA_WRF_PPW_BUSART_STY_STR-T sy-vline
WA_WRF_PPW_BUSART_STY_STR-MATNR_T sy-vline
WA_WRF_PPW_BUSART_STY_STR-SATNR_T sy-vline
WA_WRF_PPW_BUSART_STY_STR-HIER_ID_T sy-vline
WA_WRF_PPW_BUSART_STY_STR-NODE01_T sy-vline
WA_WRF_PPW_BUSART_STY_STR-NODE02_T sy-vline
WA_WRF_PPW_BUSART_STY_STR-NODE03_T sy-vline
WA_WRF_PPW_BUSART_STY_STR-NODE04_T sy-vline
WA_WRF_PPW_BUSART_STY_STR-NODE05_T sy-vline
WA_WRF_PPW_BUSART_STY_STR-NODE06_T sy-vline
WA_WRF_PPW_BUSART_STY_STR-NODE07_T sy-vline
WA_WRF_PPW_BUSART_STY_STR-NODE08_T sy-vline
WA_WRF_PPW_BUSART_STY_STR-NODE09_T sy-vline
WA_WRF_PPW_BUSART_STY_STR-NODE10_T sy-vline
WA_WRF_PPW_BUSART_STY_STR-MATKL_T sy-vline
WA_WRF_PPW_BUSART_STY_STR-VKORG_T sy-vline
WA_WRF_PPW_BUSART_STY_STR-VTWEG_T sy-vline
WA_WRF_PPW_BUSART_STY_STR-USRGRP_T sy-vline
WA_WRF_PPW_BUSART_STY_STR-VKKAB_MDP_T sy-vline
WA_WRF_PPW_BUSART_STY_STR-DISTCHAIN_T sy-vline
WA_WRF_PPW_BUSART_STY_STR-BUDG_TYPE_T sy-vline
WA_WRF_PPW_BUSART_STY_STR-RECID sy-vline
WA_WRF_PPW_BUSART_STY_STR-STATUS sy-vline
WA_WRF_PPW_BUSART_STY_STR-FILTER sy-vline
WA_WRF_PPW_BUSART_STY_STR-CHANGED sy-vline
WA_WRF_PPW_BUSART_STY_STR-DELETE_ON_SAVE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.