ABAP Select data from SAP table WRF_POTB_DATA_AUX_EKKO_STY into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP WRF_POTB_DATA_AUX_EKKO_STY table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to WRF_POTB_DATA_AUX_EKKO_STY. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the WRF_POTB_DATA_AUX_EKKO_STY table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_WRF_POTB_DATA_AUX_EKKO_STY TYPE STANDARD TABLE OF WRF_POTB_DATA_AUX_EKKO_STY,
      WA_WRF_POTB_DATA_AUX_EKKO_STY TYPE WRF_POTB_DATA_AUX_EKKO_STY,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <WRF_POTB_DATA_AUX_EKKO_STY> TYPE WRF_POTB_DATA_AUX_EKKO_STY.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_WRF_POTB_DATA_AUX_EKKO_STY.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM WRF_POTB_DATA_AUX_EKKO_STY
  INTO TABLE IT_WRF_POTB_DATA_AUX_EKKO_STY.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM WRF_POTB_DATA_AUX_EKKO_STY
*  INTO TABLE @DATA(IT_WRF_POTB_DATA_AUX_EKKO_STY2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_WRF_POTB_DATA_AUX_EKKO_STY INDEX 1 INTO DATA(WA_WRF_POTB_DATA_AUX_EKKO_STY2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_WRF_POTB_DATA_AUX_EKKO_STY ASSIGNING <WRF_POTB_DATA_AUX_EKKO_STY>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<WRF_POTB_DATA_AUX_EKKO_STY>-OTB_MISS_VALUE = 1.
<WRF_POTB_DATA_AUX_EKKO_STY>-VAL_AVAIL = 1.
<WRF_POTB_DATA_AUX_EKKO_STY>-VAL_OVERBOOK = 1.
<WRF_POTB_DATA_AUX_EKKO_STY>-VAL_TOLERANCE = 1.
<WRF_POTB_DATA_AUX_EKKO_STY>-VAL_SPENT = 1.
ENDLOOP.

LOOP AT IT_WRF_POTB_DATA_AUX_EKKO_STY INTO WA_WRF_POTB_DATA_AUX_EKKO_STY.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_WRF_POTB_DATA_AUX_EKKO_STY-VAL_SPREL, sy-vline,
WA_WRF_POTB_DATA_AUX_EKKO_STY-VAL_CONTR, sy-vline,
WA_WRF_POTB_DATA_AUX_EKKO_STY-OTB_CONTR_USED, sy-vline,
ENDLOOP. *Add any further fields from structure WA_WRF_POTB_DATA_AUX_EKKO_STY you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_WRF_POTB_DATA_AUX_EKKO_STY TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_WRF_POTB_DATA_AUX_EKKO_STY INTO WA_WRF_POTB_DATA_AUX_EKKO_STY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_WRF_POTB_DATA_AUX_EKKO_STY_STR,
OTB_MISS_VALUE TYPE STRING,
VAL_AVAIL TYPE STRING,
VAL_OVERBOOK TYPE STRING,
VAL_TOLERANCE TYPE STRING,
VAL_SPENT TYPE STRING,
VAL_SPREL TYPE STRING,
VAL_CONTR TYPE STRING,
OTB_CONTR_USED TYPE STRING,END OF T_EKKO_STR. DATA: WA_WRF_POTB_DATA_AUX_EKKO_STY_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_WRF_POTB_DATA_AUX_EKKO_STY_STR-OTB_MISS_VALUE sy-vline
WA_WRF_POTB_DATA_AUX_EKKO_STY_STR-VAL_AVAIL sy-vline
WA_WRF_POTB_DATA_AUX_EKKO_STY_STR-VAL_OVERBOOK sy-vline
WA_WRF_POTB_DATA_AUX_EKKO_STY_STR-VAL_TOLERANCE sy-vline
WA_WRF_POTB_DATA_AUX_EKKO_STY_STR-VAL_SPENT sy-vline
WA_WRF_POTB_DATA_AUX_EKKO_STY_STR-VAL_SPREL sy-vline
WA_WRF_POTB_DATA_AUX_EKKO_STY_STR-VAL_CONTR sy-vline
WA_WRF_POTB_DATA_AUX_EKKO_STY_STR-OTB_CONTR_USED sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.