ABAP Select data from SAP table WRF_POTB_DATA_AC_POTALC_STY into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP WRF_POTB_DATA_AC_POTALC_STY table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to WRF_POTB_DATA_AC_POTALC_STY. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the WRF_POTB_DATA_AC_POTALC_STY table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_WRF_POTB_DATA_AC_POTALC_STY TYPE STANDARD TABLE OF WRF_POTB_DATA_AC_POTALC_STY,
      WA_WRF_POTB_DATA_AC_POTALC_STY TYPE WRF_POTB_DATA_AC_POTALC_STY,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <WRF_POTB_DATA_AC_POTALC_STY> TYPE WRF_POTB_DATA_AC_POTALC_STY.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_WRF_POTB_DATA_AC_POTALC_STY.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM WRF_POTB_DATA_AC_POTALC_STY
  INTO TABLE IT_WRF_POTB_DATA_AC_POTALC_STY.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM WRF_POTB_DATA_AC_POTALC_STY
*  INTO TABLE @DATA(IT_WRF_POTB_DATA_AC_POTALC_STY2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_WRF_POTB_DATA_AC_POTALC_STY INDEX 1 INTO DATA(WA_WRF_POTB_DATA_AC_POTALC_STY2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_WRF_POTB_DATA_AC_POTALC_STY ASSIGNING <WRF_POTB_DATA_AC_POTALC_STY>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<WRF_POTB_DATA_AC_POTALC_STY>-PICK_ICON = 1.
<WRF_POTB_DATA_AC_POTALC_STY>-ROW_INDEX = 1.
<WRF_POTB_DATA_AC_POTALC_STY>-CELLTAB = 1.
<WRF_POTB_DATA_AC_POTALC_STY>-KEY_ID = 1.
<WRF_POTB_DATA_AC_POTALC_STY>-DATE_FROM = 1.
ENDLOOP.

LOOP AT IT_WRF_POTB_DATA_AC_POTALC_STY INTO WA_WRF_POTB_DATA_AC_POTALC_STY.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_WRF_POTB_DATA_AC_POTALC_STY-DATE_TO, sy-vline,
WA_WRF_POTB_DATA_AC_POTALC_STY-VAL_PLAN, sy-vline,
WA_WRF_POTB_DATA_AC_POTALC_STY-VAL_TRANSF, sy-vline,
WA_WRF_POTB_DATA_AC_POTALC_STY-CURRENCY, sy-vline,
WA_WRF_POTB_DATA_AC_POTALC_STY-TS_DATE_TIME, sy-vline,
WA_WRF_POTB_DATA_AC_POTALC_STY-TS_PROG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_WRF_POTB_DATA_AC_POTALC_STY you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_WRF_POTB_DATA_AC_POTALC_STY TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_WRF_POTB_DATA_AC_POTALC_STY INTO WA_WRF_POTB_DATA_AC_POTALC_STY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_WRF_POTB_DATA_AC_POTALC_STY_STR,
PICK_ICON TYPE STRING,
ROW_INDEX TYPE STRING,
CELLTAB TYPE STRING,
KEY_ID TYPE STRING,
DATE_FROM TYPE STRING,
DATE_TO TYPE STRING,
VAL_PLAN TYPE STRING,
VAL_TRANSF TYPE STRING,
CURRENCY TYPE STRING,
TS_DATE_TIME TYPE STRING,
TS_PROG TYPE STRING,
TS_USER TYPE STRING,
INACTIVE TYPE STRING,
NEGATIVE_PLAN TYPE STRING,
NEGATIVE_REASON TYPE STRING,
VAL_SPENT TYPE STRING,
VAL_SPREL TYPE STRING,
VAL_CONTR TYPE STRING,
VAL_AVAIL TYPE STRING,
VAL_OVERBOOK TYPE STRING,
VAL_TOLERANCE TYPE STRING,
TYPE TYPE STRING,END OF T_EKKO_STR. DATA: WA_WRF_POTB_DATA_AC_POTALC_STY_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_WRF_POTB_DATA_AC_POTALC_STY_STR-PICK_ICON sy-vline
WA_WRF_POTB_DATA_AC_POTALC_STY_STR-ROW_INDEX sy-vline
WA_WRF_POTB_DATA_AC_POTALC_STY_STR-CELLTAB sy-vline
WA_WRF_POTB_DATA_AC_POTALC_STY_STR-KEY_ID sy-vline
WA_WRF_POTB_DATA_AC_POTALC_STY_STR-DATE_FROM sy-vline
WA_WRF_POTB_DATA_AC_POTALC_STY_STR-DATE_TO sy-vline
WA_WRF_POTB_DATA_AC_POTALC_STY_STR-VAL_PLAN sy-vline
WA_WRF_POTB_DATA_AC_POTALC_STY_STR-VAL_TRANSF sy-vline
WA_WRF_POTB_DATA_AC_POTALC_STY_STR-CURRENCY sy-vline
WA_WRF_POTB_DATA_AC_POTALC_STY_STR-TS_DATE_TIME sy-vline
WA_WRF_POTB_DATA_AC_POTALC_STY_STR-TS_PROG sy-vline
WA_WRF_POTB_DATA_AC_POTALC_STY_STR-TS_USER sy-vline
WA_WRF_POTB_DATA_AC_POTALC_STY_STR-INACTIVE sy-vline
WA_WRF_POTB_DATA_AC_POTALC_STY_STR-NEGATIVE_PLAN sy-vline
WA_WRF_POTB_DATA_AC_POTALC_STY_STR-NEGATIVE_REASON sy-vline
WA_WRF_POTB_DATA_AC_POTALC_STY_STR-VAL_SPENT sy-vline
WA_WRF_POTB_DATA_AC_POTALC_STY_STR-VAL_SPREL sy-vline
WA_WRF_POTB_DATA_AC_POTALC_STY_STR-VAL_CONTR sy-vline
WA_WRF_POTB_DATA_AC_POTALC_STY_STR-VAL_AVAIL sy-vline
WA_WRF_POTB_DATA_AC_POTALC_STY_STR-VAL_OVERBOOK sy-vline
WA_WRF_POTB_DATA_AC_POTALC_STY_STR-VAL_TOLERANCE sy-vline
WA_WRF_POTB_DATA_AC_POTALC_STY_STR-TYPE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.