ABAP Select data from SAP table WRF_ORG_PR_DISP_STY into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP WRF_ORG_PR_DISP_STY table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to WRF_ORG_PR_DISP_STY. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the WRF_ORG_PR_DISP_STY table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_WRF_ORG_PR_DISP_STY TYPE STANDARD TABLE OF WRF_ORG_PR_DISP_STY,
      WA_WRF_ORG_PR_DISP_STY TYPE WRF_ORG_PR_DISP_STY,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <WRF_ORG_PR_DISP_STY> TYPE WRF_ORG_PR_DISP_STY.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_WRF_ORG_PR_DISP_STY.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM WRF_ORG_PR_DISP_STY
  INTO TABLE IT_WRF_ORG_PR_DISP_STY.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM WRF_ORG_PR_DISP_STY
*  INTO TABLE @DATA(IT_WRF_ORG_PR_DISP_STY2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_WRF_ORG_PR_DISP_STY INDEX 1 INTO DATA(WA_WRF_ORG_PR_DISP_STY2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_WRF_ORG_PR_DISP_STY ASSIGNING <WRF_ORG_PR_DISP_STY>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<WRF_ORG_PR_DISP_STY>-MATNR = 1.
<WRF_ORG_PR_DISP_STY>-MAKTX = 1.
<WRF_ORG_PR_DISP_STY>-ATTYP = 1.
<WRF_ORG_PR_DISP_STY>-WERKS = 1.
<WRF_ORG_PR_DISP_STY>-NAME1 = 1.
ENDLOOP.

LOOP AT IT_WRF_ORG_PR_DISP_STY INTO WA_WRF_ORG_PR_DISP_STY.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_WRF_ORG_PR_DISP_STY-VLFKZ, sy-vline,
WA_WRF_ORG_PR_DISP_STY-DATAB, sy-vline,
WA_WRF_ORG_PR_DISP_STY-DATBI, sy-vline,
WA_WRF_ORG_PR_DISP_STY-VPR_BT, sy-vline,
WA_WRF_ORG_PR_DISP_STY-VWAER_BT, sy-vline,
WA_WRF_ORG_PR_DISP_STY-VRKPE_BT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_WRF_ORG_PR_DISP_STY you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_WRF_ORG_PR_DISP_STY TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_WRF_ORG_PR_DISP_STY INTO WA_WRF_ORG_PR_DISP_STY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_WRF_ORG_PR_DISP_STY-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WRF_ORG_PR_DISP_STY-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VKMEIN_BT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_WRF_ORG_PR_DISP_STY-VKMEIN_BT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WRF_ORG_PR_DISP_STY-VKMEIN_BT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VKMEIN_NT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_WRF_ORG_PR_DISP_STY-VKMEIN_NT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WRF_ORG_PR_DISP_STY-VKMEIN_NT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_WRF_ORG_PR_DISP_STY_STR,
MATNR TYPE STRING,
MAKTX TYPE STRING,
ATTYP TYPE STRING,
WERKS TYPE STRING,
NAME1 TYPE STRING,
VLFKZ TYPE STRING,
DATAB TYPE STRING,
DATBI TYPE STRING,
VPR_BT TYPE STRING,
VWAER_BT TYPE STRING,
VRKPE_BT TYPE STRING,
VKMEIN_BT TYPE STRING,
VPR_NT TYPE STRING,
VWAER_NT TYPE STRING,
VRKPE_NT TYPE STRING,
VKMEIN_NT TYPE STRING,
VPDAT TYPE STRING,
ORIGIN TYPE STRING,
TIMESTAMP TYPE STRING,END OF T_EKKO_STR. DATA: WA_WRF_ORG_PR_DISP_STY_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_WRF_ORG_PR_DISP_STY_STR-MATNR sy-vline
WA_WRF_ORG_PR_DISP_STY_STR-MAKTX sy-vline
WA_WRF_ORG_PR_DISP_STY_STR-ATTYP sy-vline
WA_WRF_ORG_PR_DISP_STY_STR-WERKS sy-vline
WA_WRF_ORG_PR_DISP_STY_STR-NAME1 sy-vline
WA_WRF_ORG_PR_DISP_STY_STR-VLFKZ sy-vline
WA_WRF_ORG_PR_DISP_STY_STR-DATAB sy-vline
WA_WRF_ORG_PR_DISP_STY_STR-DATBI sy-vline
WA_WRF_ORG_PR_DISP_STY_STR-VPR_BT sy-vline
WA_WRF_ORG_PR_DISP_STY_STR-VWAER_BT sy-vline
WA_WRF_ORG_PR_DISP_STY_STR-VRKPE_BT sy-vline
WA_WRF_ORG_PR_DISP_STY_STR-VKMEIN_BT sy-vline
WA_WRF_ORG_PR_DISP_STY_STR-VPR_NT sy-vline
WA_WRF_ORG_PR_DISP_STY_STR-VWAER_NT sy-vline
WA_WRF_ORG_PR_DISP_STY_STR-VRKPE_NT sy-vline
WA_WRF_ORG_PR_DISP_STY_STR-VKMEIN_NT sy-vline
WA_WRF_ORG_PR_DISP_STY_STR-VPDAT sy-vline
WA_WRF_ORG_PR_DISP_STY_STR-ORIGIN sy-vline
WA_WRF_ORG_PR_DISP_STY_STR-TIMESTAMP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.