ABAP Select data from SAP table WOSE_ITEMS_SC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP WOSE_ITEMS_SC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to WOSE_ITEMS_SC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the WOSE_ITEMS_SC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_WOSE_ITEMS_SC TYPE STANDARD TABLE OF WOSE_ITEMS_SC,
      WA_WOSE_ITEMS_SC TYPE WOSE_ITEMS_SC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <WOSE_ITEMS_SC> TYPE WOSE_ITEMS_SC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_WOSE_ITEMS_SC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM WOSE_ITEMS_SC
  INTO TABLE IT_WOSE_ITEMS_SC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM WOSE_ITEMS_SC
*  INTO TABLE @DATA(IT_WOSE_ITEMS_SC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_WOSE_ITEMS_SC INDEX 1 INTO DATA(WA_WOSE_ITEMS_SC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_WOSE_ITEMS_SC ASSIGNING <WOSE_ITEMS_SC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<WOSE_ITEMS_SC>-REF_BLNR = 1.
<WOSE_ITEMS_SC>-W_EBELP_LF = 1.
<WOSE_ITEMS_SC>-EBELP = 1.
<WOSE_ITEMS_SC>-ARTNR = 1.
<WOSE_ITEMS_SC>-EAN11 = 1.
ENDLOOP.

LOOP AT IT_WOSE_ITEMS_SC INTO WA_WOSE_ITEMS_SC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_WOSE_ITEMS_SC-MATNR, sy-vline,
WA_WOSE_ITEMS_SC-IDNLF, sy-vline,
WA_WOSE_ITEMS_SC-ATTYP, sy-vline,
WA_WOSE_ITEMS_SC-MAT_ID, sy-vline,
WA_WOSE_ITEMS_SC-MATXT, sy-vline,
WA_WOSE_ITEMS_SC-BSMNG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_WOSE_ITEMS_SC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_WOSE_ITEMS_SC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_WOSE_ITEMS_SC INTO WA_WOSE_ITEMS_SC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_WOSE_ITEMS_SC_STR,
REF_BLNR TYPE STRING,
W_EBELP_LF TYPE STRING,
EBELP TYPE STRING,
ARTNR TYPE STRING,
EAN11 TYPE STRING,
MATNR TYPE STRING,
IDNLF TYPE STRING,
ATTYP TYPE STRING,
MAT_ID TYPE STRING,
MATXT TYPE STRING,
BSMNG TYPE STRING,
BSTME TYPE STRING,
WEMENGE TYPE STRING,
WEME TYPE STRING,
ELIKZ TYPE STRING,
LIEFNR TYPE STRING,
CHARGE TYPE STRING,
LGORT TYPE STRING,
W_UMMAT TYPE STRING,
W_UMWRK TYPE STRING,
W_UMLGO TYPE STRING,
KOSTL TYPE STRING,
S_KONT TYPE STRING,
GRUND TYPE STRING,
AKTNR TYPE STRING,
MHDKZ TYPE STRING,
HSDAT TYPE STRING,
VFDAT TYPE STRING,
EXVKW TYPE STRING,
ERROR_MESSAGE TYPE STRING,
W_GMNG TYPE STRING,
RETPO TYPE STRING,
SGTXT TYPE STRING,
W_LOC_OWN TYPE STRING,
W_LOC_EXT TYPE STRING,
W_LOC_PROP TYPE STRING,
MLGUT TYPE STRING,
AUSW_KZ TYPE STRING,
GL_ACC_COUNTER TYPE STRING,
DUMMY_FIELD TYPE STRING,END OF T_EKKO_STR. DATA: WA_WOSE_ITEMS_SC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_WOSE_ITEMS_SC_STR-REF_BLNR sy-vline
WA_WOSE_ITEMS_SC_STR-W_EBELP_LF sy-vline
WA_WOSE_ITEMS_SC_STR-EBELP sy-vline
WA_WOSE_ITEMS_SC_STR-ARTNR sy-vline
WA_WOSE_ITEMS_SC_STR-EAN11 sy-vline
WA_WOSE_ITEMS_SC_STR-MATNR sy-vline
WA_WOSE_ITEMS_SC_STR-IDNLF sy-vline
WA_WOSE_ITEMS_SC_STR-ATTYP sy-vline
WA_WOSE_ITEMS_SC_STR-MAT_ID sy-vline
WA_WOSE_ITEMS_SC_STR-MATXT sy-vline
WA_WOSE_ITEMS_SC_STR-BSMNG sy-vline
WA_WOSE_ITEMS_SC_STR-BSTME sy-vline
WA_WOSE_ITEMS_SC_STR-WEMENGE sy-vline
WA_WOSE_ITEMS_SC_STR-WEME sy-vline
WA_WOSE_ITEMS_SC_STR-ELIKZ sy-vline
WA_WOSE_ITEMS_SC_STR-LIEFNR sy-vline
WA_WOSE_ITEMS_SC_STR-CHARGE sy-vline
WA_WOSE_ITEMS_SC_STR-LGORT sy-vline
WA_WOSE_ITEMS_SC_STR-W_UMMAT sy-vline
WA_WOSE_ITEMS_SC_STR-W_UMWRK sy-vline
WA_WOSE_ITEMS_SC_STR-W_UMLGO sy-vline
WA_WOSE_ITEMS_SC_STR-KOSTL sy-vline
WA_WOSE_ITEMS_SC_STR-S_KONT sy-vline
WA_WOSE_ITEMS_SC_STR-GRUND sy-vline
WA_WOSE_ITEMS_SC_STR-AKTNR sy-vline
WA_WOSE_ITEMS_SC_STR-MHDKZ sy-vline
WA_WOSE_ITEMS_SC_STR-HSDAT sy-vline
WA_WOSE_ITEMS_SC_STR-VFDAT sy-vline
WA_WOSE_ITEMS_SC_STR-EXVKW sy-vline
WA_WOSE_ITEMS_SC_STR-ERROR_MESSAGE sy-vline
WA_WOSE_ITEMS_SC_STR-W_GMNG sy-vline
WA_WOSE_ITEMS_SC_STR-RETPO sy-vline
WA_WOSE_ITEMS_SC_STR-SGTXT sy-vline
WA_WOSE_ITEMS_SC_STR-W_LOC_OWN sy-vline
WA_WOSE_ITEMS_SC_STR-W_LOC_EXT sy-vline
WA_WOSE_ITEMS_SC_STR-W_LOC_PROP sy-vline
WA_WOSE_ITEMS_SC_STR-MLGUT sy-vline
WA_WOSE_ITEMS_SC_STR-AUSW_KZ sy-vline
WA_WOSE_ITEMS_SC_STR-GL_ACC_COUNTER sy-vline
WA_WOSE_ITEMS_SC_STR-DUMMY_FIELD sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.