ABAP Select data from SAP table WOSE_IMKPF_SC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP WOSE_IMKPF_SC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to WOSE_IMKPF_SC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the WOSE_IMKPF_SC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_WOSE_IMKPF_SC TYPE STANDARD TABLE OF WOSE_IMKPF_SC,
      WA_WOSE_IMKPF_SC TYPE WOSE_IMKPF_SC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <WOSE_IMKPF_SC> TYPE WOSE_IMKPF_SC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_WOSE_IMKPF_SC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM WOSE_IMKPF_SC
  INTO TABLE IT_WOSE_IMKPF_SC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM WOSE_IMKPF_SC
*  INTO TABLE @DATA(IT_WOSE_IMKPF_SC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_WOSE_IMKPF_SC INDEX 1 INTO DATA(WA_WOSE_IMKPF_SC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_WOSE_IMKPF_SC ASSIGNING <WOSE_IMKPF_SC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<WOSE_IMKPF_SC>-PLANT = 1.
<WOSE_IMKPF_SC>-NAME = 1.
<WOSE_IMKPF_SC>-ORT01 = 1.
<WOSE_IMKPF_SC>-UP_DATE = 1.
<WOSE_IMKPF_SC>-ART_ID = 1.
ENDLOOP.

LOOP AT IT_WOSE_IMKPF_SC INTO WA_WOSE_IMKPF_SC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_WOSE_IMKPF_SC-REF_BLNR, sy-vline,
WA_WOSE_IMKPF_SC-MJAHR, sy-vline,
WA_WOSE_IMKPF_SC-REF_DATE, sy-vline,
WA_WOSE_IMKPF_SC-LIFNR, sy-vline,
WA_WOSE_IMKPF_SC-LIEF_NAME, sy-vline,
WA_WOSE_IMKPF_SC-X_REF_BLNR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_WOSE_IMKPF_SC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_WOSE_IMKPF_SC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_WOSE_IMKPF_SC INTO WA_WOSE_IMKPF_SC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_WOSE_IMKPF_SC_STR,
PLANT TYPE STRING,
NAME TYPE STRING,
ORT01 TYPE STRING,
UP_DATE TYPE STRING,
ART_ID TYPE STRING,
REF_BLNR TYPE STRING,
MJAHR TYPE STRING,
REF_DATE TYPE STRING,
LIFNR TYPE STRING,
LIEF_NAME TYPE STRING,
X_REF_BLNR TYPE STRING,
BLART TYPE STRING,
W_LFDAT TYPE STRING,
REF_EXIDV TYPE STRING,
DOC_DATE TYPE STRING,
XREF_NO TYPE STRING,
ART_ID2 TYPE STRING,
REF_BLNR_DYNP TYPE STRING,
REF_ID TYPE STRING,
UP_DATE_C TYPE STRING,
DOC_DATE_C TYPE STRING,
MOVEMENT_TYPE TYPE STRING,
MOVEMENT_REASON_CONTR TYPE STRING,
MOVEMENT_REASON TYPE STRING,
DUMMY_FIELD TYPE STRING,END OF T_EKKO_STR. DATA: WA_WOSE_IMKPF_SC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_WOSE_IMKPF_SC_STR-PLANT sy-vline
WA_WOSE_IMKPF_SC_STR-NAME sy-vline
WA_WOSE_IMKPF_SC_STR-ORT01 sy-vline
WA_WOSE_IMKPF_SC_STR-UP_DATE sy-vline
WA_WOSE_IMKPF_SC_STR-ART_ID sy-vline
WA_WOSE_IMKPF_SC_STR-REF_BLNR sy-vline
WA_WOSE_IMKPF_SC_STR-MJAHR sy-vline
WA_WOSE_IMKPF_SC_STR-REF_DATE sy-vline
WA_WOSE_IMKPF_SC_STR-LIFNR sy-vline
WA_WOSE_IMKPF_SC_STR-LIEF_NAME sy-vline
WA_WOSE_IMKPF_SC_STR-X_REF_BLNR sy-vline
WA_WOSE_IMKPF_SC_STR-BLART sy-vline
WA_WOSE_IMKPF_SC_STR-W_LFDAT sy-vline
WA_WOSE_IMKPF_SC_STR-REF_EXIDV sy-vline
WA_WOSE_IMKPF_SC_STR-DOC_DATE sy-vline
WA_WOSE_IMKPF_SC_STR-XREF_NO sy-vline
WA_WOSE_IMKPF_SC_STR-ART_ID2 sy-vline
WA_WOSE_IMKPF_SC_STR-REF_BLNR_DYNP sy-vline
WA_WOSE_IMKPF_SC_STR-REF_ID sy-vline
WA_WOSE_IMKPF_SC_STR-UP_DATE_C sy-vline
WA_WOSE_IMKPF_SC_STR-DOC_DATE_C sy-vline
WA_WOSE_IMKPF_SC_STR-MOVEMENT_TYPE sy-vline
WA_WOSE_IMKPF_SC_STR-MOVEMENT_REASON_CONTR sy-vline
WA_WOSE_IMKPF_SC_STR-MOVEMENT_REASON sy-vline
WA_WOSE_IMKPF_SC_STR-DUMMY_FIELD sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.