ABAP Select data from SAP table WLK1_UEB into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP WLK1_UEB table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to WLK1_UEB. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the WLK1_UEB table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_WLK1_UEB TYPE STANDARD TABLE OF WLK1_UEB,
      WA_WLK1_UEB TYPE WLK1_UEB,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <WLK1_UEB> TYPE WLK1_UEB.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_WLK1_UEB.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM WLK1_UEB
  INTO TABLE IT_WLK1_UEB.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM WLK1_UEB
*  INTO TABLE @DATA(IT_WLK1_UEB2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_WLK1_UEB INDEX 1 INTO DATA(WA_WLK1_UEB2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_WLK1_UEB ASSIGNING <WLK1_UEB>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<WLK1_UEB>-MANDT = 1.
<WLK1_UEB>-FILIA = 1.
<WLK1_UEB>-ARTNR = 1.
<WLK1_UEB>-VRKME = 1.
<WLK1_UEB>-DATBI = 1.
ENDLOOP.

LOOP AT IT_WLK1_UEB INTO WA_WLK1_UEB.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_WLK1_UEB-LFDNR, sy-vline,
WA_WLK1_UEB-DATAB, sy-vline,
WA_WLK1_UEB-URSAC, sy-vline,
WA_WLK1_UEB-QUELL, sy-vline,
WA_WLK1_UEB-PFLKN, sy-vline,
WA_WLK1_UEB-ANZAL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_WLK1_UEB you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_WLK1_UEB TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_WLK1_UEB INTO WA_WLK1_UEB. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field FILIA CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WLK1_UEB-FILIA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WLK1_UEB-FILIA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field ARTNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_WLK1_UEB-ARTNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WLK1_UEB-ARTNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VRKME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_WLK1_UEB-VRKME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WLK1_UEB-VRKME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field URSAC CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WLK1_UEB-URSAC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WLK1_UEB-URSAC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AKTIO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WLK1_UEB-AKTIO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WLK1_UEB-AKTIO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LIFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WLK1_UEB-LIFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WLK1_UEB-LIFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field STRNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_WLK1_UEB-STRNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WLK1_UEB-STRNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit WLMV, internal->external for field LAYMOD_VER CALL FUNCTION 'CONVERSION_EXIT_WLMV_OUTPUT' EXPORTING input = WA_WLK1_UEB-LAYMOD_VER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WLK1_UEB-LAYMOD_VER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CHANGENR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WLK1_UEB-CHANGENR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WLK1_UEB-CHANGENR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WLK1_UEB-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WLK1_UEB-AENNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_WLK1_UEB_STR,
MANDT TYPE STRING,
FILIA TYPE STRING,
ARTNR TYPE STRING,
VRKME TYPE STRING,
DATBI TYPE STRING,
LFDNR TYPE STRING,
DATAB TYPE STRING,
URSAC TYPE STRING,
QUELL TYPE STRING,
PFLKN TYPE STRING,
ANZAL TYPE STRING,
DATAE TYPE STRING,
NEGAT TYPE STRING,
AKTIO TYPE STRING,
THEMA TYPE STRING,
STRLI TYPE STRING,
SSTAT TYPE STRING,
LIFNR TYPE STRING,
STRNR TYPE STRING,
LAYGR TYPE STRING,
LAYMOD_VER TYPE STRING,
CHANGEID TYPE STRING,
TRANC TYPE STRING,
D_IND TYPE STRING,
KZ_RES TYPE STRING,
CHANGENR TYPE STRING,
AENNR TYPE STRING,END OF T_EKKO_STR. DATA: WA_WLK1_UEB_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_WLK1_UEB_STR-MANDT sy-vline
WA_WLK1_UEB_STR-FILIA sy-vline
WA_WLK1_UEB_STR-ARTNR sy-vline
WA_WLK1_UEB_STR-VRKME sy-vline
WA_WLK1_UEB_STR-DATBI sy-vline
WA_WLK1_UEB_STR-LFDNR sy-vline
WA_WLK1_UEB_STR-DATAB sy-vline
WA_WLK1_UEB_STR-URSAC sy-vline
WA_WLK1_UEB_STR-QUELL sy-vline
WA_WLK1_UEB_STR-PFLKN sy-vline
WA_WLK1_UEB_STR-ANZAL sy-vline
WA_WLK1_UEB_STR-DATAE sy-vline
WA_WLK1_UEB_STR-NEGAT sy-vline
WA_WLK1_UEB_STR-AKTIO sy-vline
WA_WLK1_UEB_STR-THEMA sy-vline
WA_WLK1_UEB_STR-STRLI sy-vline
WA_WLK1_UEB_STR-SSTAT sy-vline
WA_WLK1_UEB_STR-LIFNR sy-vline
WA_WLK1_UEB_STR-STRNR sy-vline
WA_WLK1_UEB_STR-LAYGR sy-vline
WA_WLK1_UEB_STR-LAYMOD_VER sy-vline
WA_WLK1_UEB_STR-CHANGEID sy-vline
WA_WLK1_UEB_STR-TRANC sy-vline
WA_WLK1_UEB_STR-D_IND sy-vline
WA_WLK1_UEB_STR-KZ_RES sy-vline
WA_WLK1_UEB_STR-CHANGENR sy-vline
WA_WLK1_UEB_STR-AENNR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.