ABAP Select data from SAP table WLFS_COBL_DYNPRO_FIELDS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP WLFS_COBL_DYNPRO_FIELDS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to WLFS_COBL_DYNPRO_FIELDS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the WLFS_COBL_DYNPRO_FIELDS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_WLFS_COBL_DYNPRO_FIELDS TYPE STANDARD TABLE OF WLFS_COBL_DYNPRO_FIELDS,
      WA_WLFS_COBL_DYNPRO_FIELDS TYPE WLFS_COBL_DYNPRO_FIELDS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <WLFS_COBL_DYNPRO_FIELDS> TYPE WLFS_COBL_DYNPRO_FIELDS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_WLFS_COBL_DYNPRO_FIELDS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM WLFS_COBL_DYNPRO_FIELDS
  INTO TABLE IT_WLFS_COBL_DYNPRO_FIELDS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM WLFS_COBL_DYNPRO_FIELDS
*  INTO TABLE @DATA(IT_WLFS_COBL_DYNPRO_FIELDS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_WLFS_COBL_DYNPRO_FIELDS INDEX 1 INTO DATA(WA_WLFS_COBL_DYNPRO_FIELDS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_WLFS_COBL_DYNPRO_FIELDS ASSIGNING <WLFS_COBL_DYNPRO_FIELDS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<WLFS_COBL_DYNPRO_FIELDS>-GSBER = 1.
<WLFS_COBL_DYNPRO_FIELDS>-PRCTR = 1.
<WLFS_COBL_DYNPRO_FIELDS>-KOSTL = 1.
<WLFS_COBL_DYNPRO_FIELDS>-AUFNR = 1.
<WLFS_COBL_DYNPRO_FIELDS>-PS_PSP_PNR = 1.
ENDLOOP.

LOOP AT IT_WLFS_COBL_DYNPRO_FIELDS INTO WA_WLFS_COBL_DYNPRO_FIELDS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_WLFS_COBL_DYNPRO_FIELDS-PAOBJNR, sy-vline,
WA_WLFS_COBL_DYNPRO_FIELDS-GSBERD, sy-vline,
WA_WLFS_COBL_DYNPRO_FIELDS-PRCTRD, sy-vline,
WA_WLFS_COBL_DYNPRO_FIELDS-KOSTLD, sy-vline,
WA_WLFS_COBL_DYNPRO_FIELDS-AUFNRD, sy-vline,
WA_WLFS_COBL_DYNPRO_FIELDS-PS_PSP_PNRD, sy-vline.
ENDLOOP. *Add any further fields from structure WA_WLFS_COBL_DYNPRO_FIELDS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_WLFS_COBL_DYNPRO_FIELDS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_WLFS_COBL_DYNPRO_FIELDS INTO WA_WLFS_COBL_DYNPRO_FIELDS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field PRCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WLFS_COBL_DYNPRO_FIELDS-PRCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WLFS_COBL_DYNPRO_FIELDS-PRCTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KOSTL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WLFS_COBL_DYNPRO_FIELDS-KOSTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WLFS_COBL_DYNPRO_FIELDS-KOSTL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WLFS_COBL_DYNPRO_FIELDS-AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WLFS_COBL_DYNPRO_FIELDS-AUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSP, internal->external for field PS_PSP_PNR CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_WLFS_COBL_DYNPRO_FIELDS-PS_PSP_PNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WLFS_COBL_DYNPRO_FIELDS-PS_PSP_PNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRCTRD CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WLFS_COBL_DYNPRO_FIELDS-PRCTRD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WLFS_COBL_DYNPRO_FIELDS-PRCTRD.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KOSTLD CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WLFS_COBL_DYNPRO_FIELDS-KOSTLD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WLFS_COBL_DYNPRO_FIELDS-KOSTLD.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AUFNRD CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WLFS_COBL_DYNPRO_FIELDS-AUFNRD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WLFS_COBL_DYNPRO_FIELDS-AUFNRD.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSP, internal->external for field PS_PSP_PNRD CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_WLFS_COBL_DYNPRO_FIELDS-PS_PSP_PNRD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WLFS_COBL_DYNPRO_FIELDS-PS_PSP_PNRD.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_WLFS_COBL_DYNPRO_FIELDS_STR,
GSBER TYPE STRING,
PRCTR TYPE STRING,
KOSTL TYPE STRING,
AUFNR TYPE STRING,
PS_PSP_PNR TYPE STRING,
PAOBJNR TYPE STRING,
GSBERD TYPE STRING,
PRCTRD TYPE STRING,
KOSTLD TYPE STRING,
AUFNRD TYPE STRING,
PS_PSP_PNRD TYPE STRING,
PAOBJNRD TYPE STRING,END OF T_EKKO_STR. DATA: WA_WLFS_COBL_DYNPRO_FIELDS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_WLFS_COBL_DYNPRO_FIELDS_STR-GSBER sy-vline
WA_WLFS_COBL_DYNPRO_FIELDS_STR-PRCTR sy-vline
WA_WLFS_COBL_DYNPRO_FIELDS_STR-KOSTL sy-vline
WA_WLFS_COBL_DYNPRO_FIELDS_STR-AUFNR sy-vline
WA_WLFS_COBL_DYNPRO_FIELDS_STR-PS_PSP_PNR sy-vline
WA_WLFS_COBL_DYNPRO_FIELDS_STR-PAOBJNR sy-vline
WA_WLFS_COBL_DYNPRO_FIELDS_STR-GSBERD sy-vline
WA_WLFS_COBL_DYNPRO_FIELDS_STR-PRCTRD sy-vline
WA_WLFS_COBL_DYNPRO_FIELDS_STR-KOSTLD sy-vline
WA_WLFS_COBL_DYNPRO_FIELDS_STR-AUFNRD sy-vline
WA_WLFS_COBL_DYNPRO_FIELDS_STR-PS_PSP_PNRD sy-vline
WA_WLFS_COBL_DYNPRO_FIELDS_STR-PAOBJNRD sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.