ABAP Select data from SAP table WINT_AUS1 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP WINT_AUS1 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to WINT_AUS1. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the WINT_AUS1 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_WINT_AUS1 TYPE STANDARD TABLE OF WINT_AUS1,
      WA_WINT_AUS1 TYPE WINT_AUS1,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <WINT_AUS1> TYPE WINT_AUS1.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_WINT_AUS1.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM WINT_AUS1
  INTO TABLE IT_WINT_AUS1.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM WINT_AUS1
*  INTO TABLE @DATA(IT_WINT_AUS12).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_WINT_AUS1 INDEX 1 INTO DATA(WA_WINT_AUS12).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_WINT_AUS1 ASSIGNING <WINT_AUS1>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<WINT_AUS1>-MANDT = 1.
<WINT_AUS1>-OBJEK = 1.
<WINT_AUS1>-ATINN = 1.
<WINT_AUS1>-ATZHL = 1.
<WINT_AUS1>-MAFID = 1.
ENDLOOP.

LOOP AT IT_WINT_AUS1 INTO WA_WINT_AUS1.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_WINT_AUS1-KLART, sy-vline,
WA_WINT_AUS1-ADZHL, sy-vline,
WA_WINT_AUS1-ATWRT, sy-vline,
WA_WINT_AUS1-ATFLV, sy-vline,
WA_WINT_AUS1-ATAWE, sy-vline,
WA_WINT_AUS1-ATFLB, sy-vline.
ENDLOOP. *Add any further fields from structure WA_WINT_AUS1 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_WINT_AUS1 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_WINT_AUS1 INTO WA_WINT_AUS1. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ATINN, internal->external for field ATINN CALL FUNCTION 'CONVERSION_EXIT_ATINN_OUTPUT' EXPORTING input = WA_WINT_AUS1-ATINN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WINT_AUS1-ATINN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ATAWE CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_WINT_AUS1-ATAWE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WINT_AUS1-ATAWE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ATAW1 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_WINT_AUS1-ATAW1 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WINT_AUS1-ATAW1.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WINT_AUS1-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WINT_AUS1-AENNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_WINT_AUS1_STR,
MANDT TYPE STRING,
OBJEK TYPE STRING,
ATINN TYPE STRING,
ATZHL TYPE STRING,
MAFID TYPE STRING,
KLART TYPE STRING,
ADZHL TYPE STRING,
ATWRT TYPE STRING,
ATFLV TYPE STRING,
ATAWE TYPE STRING,
ATFLB TYPE STRING,
ATAW1 TYPE STRING,
ATCOD TYPE STRING,
ATTLV TYPE STRING,
ATTLB TYPE STRING,
ATPRZ TYPE STRING,
ATINC TYPE STRING,
ATAUT TYPE STRING,
AENNR TYPE STRING,
DATUV TYPE STRING,
LKENZ TYPE STRING,
ATBEZ TYPE STRING,END OF T_EKKO_STR. DATA: WA_WINT_AUS1_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_WINT_AUS1_STR-MANDT sy-vline
WA_WINT_AUS1_STR-OBJEK sy-vline
WA_WINT_AUS1_STR-ATINN sy-vline
WA_WINT_AUS1_STR-ATZHL sy-vline
WA_WINT_AUS1_STR-MAFID sy-vline
WA_WINT_AUS1_STR-KLART sy-vline
WA_WINT_AUS1_STR-ADZHL sy-vline
WA_WINT_AUS1_STR-ATWRT sy-vline
WA_WINT_AUS1_STR-ATFLV sy-vline
WA_WINT_AUS1_STR-ATAWE sy-vline
WA_WINT_AUS1_STR-ATFLB sy-vline
WA_WINT_AUS1_STR-ATAW1 sy-vline
WA_WINT_AUS1_STR-ATCOD sy-vline
WA_WINT_AUS1_STR-ATTLV sy-vline
WA_WINT_AUS1_STR-ATTLB sy-vline
WA_WINT_AUS1_STR-ATPRZ sy-vline
WA_WINT_AUS1_STR-ATINC sy-vline
WA_WINT_AUS1_STR-ATAUT sy-vline
WA_WINT_AUS1_STR-AENNR sy-vline
WA_WINT_AUS1_STR-DATUV sy-vline
WA_WINT_AUS1_STR-LKENZ sy-vline
WA_WINT_AUS1_STR-ATBEZ sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.