ABAP Select data from SAP table WFDSS_WL_BACKLOG into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP WFDSS_WL_BACKLOG table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to WFDSS_WL_BACKLOG. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the WFDSS_WL_BACKLOG table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_WFDSS_WL_BACKLOG TYPE STANDARD TABLE OF WFDSS_WL_BACKLOG,
      WA_WFDSS_WL_BACKLOG TYPE WFDSS_WL_BACKLOG,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <WFDSS_WL_BACKLOG> TYPE WFDSS_WL_BACKLOG.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_WFDSS_WL_BACKLOG.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM WFDSS_WL_BACKLOG
  INTO TABLE IT_WFDSS_WL_BACKLOG.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM WFDSS_WL_BACKLOG
*  INTO TABLE @DATA(IT_WFDSS_WL_BACKLOG2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_WFDSS_WL_BACKLOG INDEX 1 INTO DATA(WA_WFDSS_WL_BACKLOG2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_WFDSS_WL_BACKLOG ASSIGNING <WFDSS_WL_BACKLOG>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<WFDSS_WL_BACKLOG>-GUID = 1.
<WFDSS_WL_BACKLOG>-PARENT = 1.
<WFDSS_WL_BACKLOG>-HEADER = 1.
<WFDSS_WL_BACKLOG>-DISPO_FLG = 1.
<WFDSS_WL_BACKLOG>-ERR_FLG = 1.
ENDLOOP.

LOOP AT IT_WFDSS_WL_BACKLOG INTO WA_WFDSS_WL_BACKLOG.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_WFDSS_WL_BACKLOG-STAT_COMPL, sy-vline,
WA_WFDSS_WL_BACKLOG-DEMAND_TYPE, sy-vline,
WA_WFDSS_WL_BACKLOG-NUMBER_INT, sy-vline,
WA_WFDSS_WL_BACKLOG-DESCRIPTION, sy-vline,
WA_WFDSS_WL_BACKLOG-DURATION, sy-vline,
WA_WFDSS_WL_BACKLOG-DURATION_UNIT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_WFDSS_WL_BACKLOG you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_WFDSS_WL_BACKLOG TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_WFDSS_WL_BACKLOG INTO WA_WFDSS_WL_BACKLOG. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field DURATION_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_WFDSS_WL_BACKLOG-DURATION_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WFDSS_WL_BACKLOG-DURATION_UNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_WFDSS_WL_BACKLOG_STR,
GUID TYPE STRING,
PARENT TYPE STRING,
HEADER TYPE STRING,
DISPO_FLG TYPE STRING,
ERR_FLG TYPE STRING,
STAT_COMPL TYPE STRING,
DEMAND_TYPE TYPE STRING,
NUMBER_INT TYPE STRING,
DESCRIPTION TYPE STRING,
DURATION TYPE STRING,
DURATION_UNIT TYPE STRING,
BEGDA TYPE STRING,
BEG_UZEIT TYPE STRING,
ENDDA TYPE STRING,
END_UZEIT TYPE STRING,
OBJECT_ID TYPE STRING,
HEADER_DESC TYPE STRING,
SERV_OBJID TYPE STRING,
SERV_STEXT TYPE STRING,END OF T_EKKO_STR. DATA: WA_WFDSS_WL_BACKLOG_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_WFDSS_WL_BACKLOG_STR-GUID sy-vline
WA_WFDSS_WL_BACKLOG_STR-PARENT sy-vline
WA_WFDSS_WL_BACKLOG_STR-HEADER sy-vline
WA_WFDSS_WL_BACKLOG_STR-DISPO_FLG sy-vline
WA_WFDSS_WL_BACKLOG_STR-ERR_FLG sy-vline
WA_WFDSS_WL_BACKLOG_STR-STAT_COMPL sy-vline
WA_WFDSS_WL_BACKLOG_STR-DEMAND_TYPE sy-vline
WA_WFDSS_WL_BACKLOG_STR-NUMBER_INT sy-vline
WA_WFDSS_WL_BACKLOG_STR-DESCRIPTION sy-vline
WA_WFDSS_WL_BACKLOG_STR-DURATION sy-vline
WA_WFDSS_WL_BACKLOG_STR-DURATION_UNIT sy-vline
WA_WFDSS_WL_BACKLOG_STR-BEGDA sy-vline
WA_WFDSS_WL_BACKLOG_STR-BEG_UZEIT sy-vline
WA_WFDSS_WL_BACKLOG_STR-ENDDA sy-vline
WA_WFDSS_WL_BACKLOG_STR-END_UZEIT sy-vline
WA_WFDSS_WL_BACKLOG_STR-OBJECT_ID sy-vline
WA_WFDSS_WL_BACKLOG_STR-HEADER_DESC sy-vline
WA_WFDSS_WL_BACKLOG_STR-SERV_OBJID sy-vline
WA_WFDSS_WL_BACKLOG_STR-SERV_STEXT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.