ABAP Select data from SAP table WDY_ENHWDYV into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP WDY_ENHWDYV table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to WDY_ENHWDYV. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the WDY_ENHWDYV table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_WDY_ENHWDYV TYPE STANDARD TABLE OF WDY_ENHWDYV,
      WA_WDY_ENHWDYV TYPE WDY_ENHWDYV,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <WDY_ENHWDYV> TYPE WDY_ENHWDYV.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_WDY_ENHWDYV.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM WDY_ENHWDYV
  INTO TABLE IT_WDY_ENHWDYV.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM WDY_ENHWDYV
*  INTO TABLE @DATA(IT_WDY_ENHWDYV2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_WDY_ENHWDYV INDEX 1 INTO DATA(WA_WDY_ENHWDYV2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_WDY_ENHWDYV ASSIGNING <WDY_ENHWDYV>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<WDY_ENHWDYV>-ENHANCEMENT_NAME = 1.
<WDY_ENHWDYV>-STATE = 1.
<WDY_ENHWDYV>-VIEW_DATA = 1.
<WDY_ENHWDYV>-VIEW_NAME = 1.
<WDY_ENHWDYV>-UI_ELEMENTS = 1.
ENDLOOP.

LOOP AT IT_WDY_ENHWDYV INTO WA_WDY_ENHWDYV.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_WDY_ENHWDYV-UI_ELEMENT_STATE, sy-vline,
WA_WDY_ENHWDYV-UI_ELEMENT_PROPERTIES, sy-vline,
WA_WDY_ENHWDYV-UI_ELEMENT_CTX_BINDINGS, sy-vline,
WA_WDY_ENHWDYV-UI_ELEMENT_DDIC_BINDINGS, sy-vline,
WA_WDY_ENHWDYV-UI_ELEMENT_EVENT_BINDINGS, sy-vline,
WA_WDY_ENHWDYV-IOBOUND_PLUGS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_WDY_ENHWDYV you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_WDY_ENHWDYV TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_WDY_ENHWDYV INTO WA_WDY_ENHWDYV. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_WDY_ENHWDYV_STR,
ENHANCEMENT_NAME TYPE STRING,
STATE TYPE STRING,
VIEW_DATA TYPE STRING,
VIEW_NAME TYPE STRING,
UI_ELEMENTS TYPE STRING,
UI_ELEMENT_STATE TYPE STRING,
UI_ELEMENT_PROPERTIES TYPE STRING,
UI_ELEMENT_CTX_BINDINGS TYPE STRING,
UI_ELEMENT_DDIC_BINDINGS TYPE STRING,
UI_ELEMENT_EVENT_BINDINGS TYPE STRING,
IOBOUND_PLUGS TYPE STRING,
IOBOUND_PLUG_PARAMS TYPE STRING,
SOTR_USE TYPE STRING,
PLUG_DESCRIPTIONS TYPE STRING,
PLUG_PARAMETER_DESCRIPTIONS TYPE STRING,
NAVIGATION_LINKS TYPE STRING,
NAVIGATION_TARGET_REFERENCES TYPE STRING,
NAVIGATION_TARGET_STATE TYPE STRING,
VIEW_CONTAINERS TYPE STRING,
VSH_NODES TYPE STRING,
VSH_PLACEHOLDERS TYPE STRING,
DEFINITION TYPE STRING,
COMPONENT_NAME TYPE STRING,
VIEW_NAME TYPE STRING,
VERSION TYPE STRING,
TYPE TYPE STRING,
VIEW_TYPE TYPE STRING,
LIFESPAN TYPE STRING,
VIEW_CONTROLLER TYPE STRING,
ROOT_UI_CONT TYPE STRING,
IS_CONVERTED TYPE STRING,
DISPLAY_NAME TYPE STRING,
AUTHOR TYPE STRING,
CREATEDON TYPE STRING,
CHANGEDBY TYPE STRING,
CHANGEDON TYPE STRING,
COMPUSAGE_NAME TYPE STRING,
DEF_ROOT_NODE TYPE STRING,
TITLE TYPE STRING,
HELP_DESCRIPTION TYPE STRING,
HELP_LINK TYPE STRING,
VISIBILITY TYPE STRING,
DESCRIPTION TYPE STRING,
OBJECT_NAME TYPE STRING,
SEC_OBJECT_NAME TYPE STRING,
DESCRIPTION TYPE STRING,
LAYOUT_CHANGE_DATE TYPE STRING,
LAYOUT_CHANGE_TIME TYPE STRING,
ELEMENT_POS_STRING TYPE STRING,
CHANGE_DATE TYPE STRING,
CHANGE_TIME TYPE STRING,END OF T_EKKO_STR. DATA: WA_WDY_ENHWDYV_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_WDY_ENHWDYV_STR-ENHANCEMENT_NAME sy-vline
WA_WDY_ENHWDYV_STR-STATE sy-vline
WA_WDY_ENHWDYV_STR-VIEW_DATA sy-vline
WA_WDY_ENHWDYV_STR-VIEW_NAME sy-vline
WA_WDY_ENHWDYV_STR-UI_ELEMENTS sy-vline
WA_WDY_ENHWDYV_STR-UI_ELEMENT_STATE sy-vline
WA_WDY_ENHWDYV_STR-UI_ELEMENT_PROPERTIES sy-vline
WA_WDY_ENHWDYV_STR-UI_ELEMENT_CTX_BINDINGS sy-vline
WA_WDY_ENHWDYV_STR-UI_ELEMENT_DDIC_BINDINGS sy-vline
WA_WDY_ENHWDYV_STR-UI_ELEMENT_EVENT_BINDINGS sy-vline
WA_WDY_ENHWDYV_STR-IOBOUND_PLUGS sy-vline
WA_WDY_ENHWDYV_STR-IOBOUND_PLUG_PARAMS sy-vline
WA_WDY_ENHWDYV_STR-SOTR_USE sy-vline
WA_WDY_ENHWDYV_STR-PLUG_DESCRIPTIONS sy-vline
WA_WDY_ENHWDYV_STR-PLUG_PARAMETER_DESCRIPTIONS sy-vline
WA_WDY_ENHWDYV_STR-NAVIGATION_LINKS sy-vline
WA_WDY_ENHWDYV_STR-NAVIGATION_TARGET_REFERENCES sy-vline
WA_WDY_ENHWDYV_STR-NAVIGATION_TARGET_STATE sy-vline
WA_WDY_ENHWDYV_STR-VIEW_CONTAINERS sy-vline
WA_WDY_ENHWDYV_STR-VSH_NODES sy-vline
WA_WDY_ENHWDYV_STR-VSH_PLACEHOLDERS sy-vline
WA_WDY_ENHWDYV_STR-DEFINITION sy-vline
WA_WDY_ENHWDYV_STR-COMPONENT_NAME sy-vline
WA_WDY_ENHWDYV_STR-VIEW_NAME sy-vline
WA_WDY_ENHWDYV_STR-VERSION sy-vline
WA_WDY_ENHWDYV_STR-TYPE sy-vline
WA_WDY_ENHWDYV_STR-VIEW_TYPE sy-vline
WA_WDY_ENHWDYV_STR-LIFESPAN sy-vline
WA_WDY_ENHWDYV_STR-VIEW_CONTROLLER sy-vline
WA_WDY_ENHWDYV_STR-ROOT_UI_CONT sy-vline
WA_WDY_ENHWDYV_STR-IS_CONVERTED sy-vline
WA_WDY_ENHWDYV_STR-DISPLAY_NAME sy-vline
WA_WDY_ENHWDYV_STR-AUTHOR sy-vline
WA_WDY_ENHWDYV_STR-CREATEDON sy-vline
WA_WDY_ENHWDYV_STR-CHANGEDBY sy-vline
WA_WDY_ENHWDYV_STR-CHANGEDON sy-vline
WA_WDY_ENHWDYV_STR-COMPUSAGE_NAME sy-vline
WA_WDY_ENHWDYV_STR-DEF_ROOT_NODE sy-vline
WA_WDY_ENHWDYV_STR-TITLE sy-vline
WA_WDY_ENHWDYV_STR-HELP_DESCRIPTION sy-vline
WA_WDY_ENHWDYV_STR-HELP_LINK sy-vline
WA_WDY_ENHWDYV_STR-VISIBILITY sy-vline
WA_WDY_ENHWDYV_STR-DESCRIPTION sy-vline
WA_WDY_ENHWDYV_STR-OBJECT_NAME sy-vline
WA_WDY_ENHWDYV_STR-SEC_OBJECT_NAME sy-vline
WA_WDY_ENHWDYV_STR-DESCRIPTION sy-vline
WA_WDY_ENHWDYV_STR-LAYOUT_CHANGE_DATE sy-vline
WA_WDY_ENHWDYV_STR-LAYOUT_CHANGE_TIME sy-vline
WA_WDY_ENHWDYV_STR-ELEMENT_POS_STRING sy-vline
WA_WDY_ENHWDYV_STR-CHANGE_DATE sy-vline
WA_WDY_ENHWDYV_STR-CHANGE_TIME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.