ABAP Select data from SAP table WCS_SP_WP_NODE_WORK into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP WCS_SP_WP_NODE_WORK table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to WCS_SP_WP_NODE_WORK. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the WCS_SP_WP_NODE_WORK table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_WCS_SP_WP_NODE_WORK TYPE STANDARD TABLE OF WCS_SP_WP_NODE_WORK,
      WA_WCS_SP_WP_NODE_WORK TYPE WCS_SP_WP_NODE_WORK,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <WCS_SP_WP_NODE_WORK> TYPE WCS_SP_WP_NODE_WORK.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_WCS_SP_WP_NODE_WORK.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM WCS_SP_WP_NODE_WORK
  INTO TABLE IT_WCS_SP_WP_NODE_WORK.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM WCS_SP_WP_NODE_WORK
*  INTO TABLE @DATA(IT_WCS_SP_WP_NODE_WORK2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_WCS_SP_WP_NODE_WORK INDEX 1 INTO DATA(WA_WCS_SP_WP_NODE_WORK2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_WCS_SP_WP_NODE_WORK ASSIGNING <WCS_SP_WP_NODE_WORK>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<WCS_SP_WP_NODE_WORK>-EAMS_OBJNR = 1.
<WCS_SP_WP_NODE_WORK>-WK01 = 1.
<WCS_SP_WP_NODE_WORK>-WK02 = 1.
<WCS_SP_WP_NODE_WORK>-WK03 = 1.
<WCS_SP_WP_NODE_WORK>-WK04 = 1.
ENDLOOP.

LOOP AT IT_WCS_SP_WP_NODE_WORK INTO WA_WCS_SP_WP_NODE_WORK.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_WCS_SP_WP_NODE_WORK-WK05, sy-vline,
WA_WCS_SP_WP_NODE_WORK-WK06, sy-vline,
WA_WCS_SP_WP_NODE_WORK-WK07, sy-vline,
WA_WCS_SP_WP_NODE_WORK-WK08, sy-vline,
WA_WCS_SP_WP_NODE_WORK-WK09, sy-vline,
WA_WCS_SP_WP_NODE_WORK-WK10, sy-vline.
ENDLOOP. *Add any further fields from structure WA_WCS_SP_WP_NODE_WORK you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_WCS_SP_WP_NODE_WORK TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_WCS_SP_WP_NODE_WORK INTO WA_WCS_SP_WP_NODE_WORK. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_WCS_SP_WP_NODE_WORK_STR,
EAMS_OBJNR TYPE STRING,
WK01 TYPE STRING,
WK02 TYPE STRING,
WK03 TYPE STRING,
WK04 TYPE STRING,
WK05 TYPE STRING,
WK06 TYPE STRING,
WK07 TYPE STRING,
WK08 TYPE STRING,
WK09 TYPE STRING,
WK10 TYPE STRING,
WK11 TYPE STRING,
WK12 TYPE STRING,
WK13 TYPE STRING,
WK14 TYPE STRING,
WK15 TYPE STRING,
WK16 TYPE STRING,
WK17 TYPE STRING,
WK18 TYPE STRING,
WK19 TYPE STRING,
WK20 TYPE STRING,
WK21 TYPE STRING,
WK22 TYPE STRING,
WK23 TYPE STRING,
WK24 TYPE STRING,
WK25 TYPE STRING,
WK26 TYPE STRING,
WK27 TYPE STRING,
WK28 TYPE STRING,
EDITABLE TYPE STRING,END OF T_EKKO_STR. DATA: WA_WCS_SP_WP_NODE_WORK_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_WCS_SP_WP_NODE_WORK_STR-EAMS_OBJNR sy-vline
WA_WCS_SP_WP_NODE_WORK_STR-WK01 sy-vline
WA_WCS_SP_WP_NODE_WORK_STR-WK02 sy-vline
WA_WCS_SP_WP_NODE_WORK_STR-WK03 sy-vline
WA_WCS_SP_WP_NODE_WORK_STR-WK04 sy-vline
WA_WCS_SP_WP_NODE_WORK_STR-WK05 sy-vline
WA_WCS_SP_WP_NODE_WORK_STR-WK06 sy-vline
WA_WCS_SP_WP_NODE_WORK_STR-WK07 sy-vline
WA_WCS_SP_WP_NODE_WORK_STR-WK08 sy-vline
WA_WCS_SP_WP_NODE_WORK_STR-WK09 sy-vline
WA_WCS_SP_WP_NODE_WORK_STR-WK10 sy-vline
WA_WCS_SP_WP_NODE_WORK_STR-WK11 sy-vline
WA_WCS_SP_WP_NODE_WORK_STR-WK12 sy-vline
WA_WCS_SP_WP_NODE_WORK_STR-WK13 sy-vline
WA_WCS_SP_WP_NODE_WORK_STR-WK14 sy-vline
WA_WCS_SP_WP_NODE_WORK_STR-WK15 sy-vline
WA_WCS_SP_WP_NODE_WORK_STR-WK16 sy-vline
WA_WCS_SP_WP_NODE_WORK_STR-WK17 sy-vline
WA_WCS_SP_WP_NODE_WORK_STR-WK18 sy-vline
WA_WCS_SP_WP_NODE_WORK_STR-WK19 sy-vline
WA_WCS_SP_WP_NODE_WORK_STR-WK20 sy-vline
WA_WCS_SP_WP_NODE_WORK_STR-WK21 sy-vline
WA_WCS_SP_WP_NODE_WORK_STR-WK22 sy-vline
WA_WCS_SP_WP_NODE_WORK_STR-WK23 sy-vline
WA_WCS_SP_WP_NODE_WORK_STR-WK24 sy-vline
WA_WCS_SP_WP_NODE_WORK_STR-WK25 sy-vline
WA_WCS_SP_WP_NODE_WORK_STR-WK26 sy-vline
WA_WCS_SP_WP_NODE_WORK_STR-WK27 sy-vline
WA_WCS_SP_WP_NODE_WORK_STR-WK28 sy-vline
WA_WCS_SP_WP_NODE_WORK_STR-EDITABLE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.