ABAP Select data from SAP table WCS_SP_WP_NODE_NEED into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP WCS_SP_WP_NODE_NEED table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to WCS_SP_WP_NODE_NEED. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the WCS_SP_WP_NODE_NEED table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_WCS_SP_WP_NODE_NEED TYPE STANDARD TABLE OF WCS_SP_WP_NODE_NEED,
      WA_WCS_SP_WP_NODE_NEED TYPE WCS_SP_WP_NODE_NEED,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <WCS_SP_WP_NODE_NEED> TYPE WCS_SP_WP_NODE_NEED.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_WCS_SP_WP_NODE_NEED.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM WCS_SP_WP_NODE_NEED
  INTO TABLE IT_WCS_SP_WP_NODE_NEED.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM WCS_SP_WP_NODE_NEED
*  INTO TABLE @DATA(IT_WCS_SP_WP_NODE_NEED2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_WCS_SP_WP_NODE_NEED INDEX 1 INTO DATA(WA_WCS_SP_WP_NODE_NEED2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_WCS_SP_WP_NODE_NEED ASSIGNING <WCS_SP_WP_NODE_NEED>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<WCS_SP_WP_NODE_NEED>-EAMS_OBJNR = 1.
<WCS_SP_WP_NODE_NEED>-NEED01 = 1.
<WCS_SP_WP_NODE_NEED>-NEED02 = 1.
<WCS_SP_WP_NODE_NEED>-NEED03 = 1.
<WCS_SP_WP_NODE_NEED>-NEED04 = 1.
ENDLOOP.

LOOP AT IT_WCS_SP_WP_NODE_NEED INTO WA_WCS_SP_WP_NODE_NEED.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_WCS_SP_WP_NODE_NEED-NEED05, sy-vline,
WA_WCS_SP_WP_NODE_NEED-NEED06, sy-vline,
WA_WCS_SP_WP_NODE_NEED-NEED07, sy-vline,
WA_WCS_SP_WP_NODE_NEED-NEED08, sy-vline,
WA_WCS_SP_WP_NODE_NEED-NEED09, sy-vline,
WA_WCS_SP_WP_NODE_NEED-NEED10, sy-vline.
ENDLOOP. *Add any further fields from structure WA_WCS_SP_WP_NODE_NEED you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_WCS_SP_WP_NODE_NEED TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_WCS_SP_WP_NODE_NEED INTO WA_WCS_SP_WP_NODE_NEED. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_WCS_SP_WP_NODE_NEED_STR,
EAMS_OBJNR TYPE STRING,
NEED01 TYPE STRING,
NEED02 TYPE STRING,
NEED03 TYPE STRING,
NEED04 TYPE STRING,
NEED05 TYPE STRING,
NEED06 TYPE STRING,
NEED07 TYPE STRING,
NEED08 TYPE STRING,
NEED09 TYPE STRING,
NEED10 TYPE STRING,
NEED11 TYPE STRING,
NEED12 TYPE STRING,
NEED13 TYPE STRING,
NEED14 TYPE STRING,
NEED15 TYPE STRING,
NEED16 TYPE STRING,
NEED17 TYPE STRING,
NEED18 TYPE STRING,
NEED19 TYPE STRING,
NEED20 TYPE STRING,
NEED21 TYPE STRING,
NEED22 TYPE STRING,
NEED23 TYPE STRING,
NEED24 TYPE STRING,
NEED25 TYPE STRING,
NEED26 TYPE STRING,
NEED27 TYPE STRING,
NEED28 TYPE STRING,
EDITABLE TYPE STRING,END OF T_EKKO_STR. DATA: WA_WCS_SP_WP_NODE_NEED_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_WCS_SP_WP_NODE_NEED_STR-EAMS_OBJNR sy-vline
WA_WCS_SP_WP_NODE_NEED_STR-NEED01 sy-vline
WA_WCS_SP_WP_NODE_NEED_STR-NEED02 sy-vline
WA_WCS_SP_WP_NODE_NEED_STR-NEED03 sy-vline
WA_WCS_SP_WP_NODE_NEED_STR-NEED04 sy-vline
WA_WCS_SP_WP_NODE_NEED_STR-NEED05 sy-vline
WA_WCS_SP_WP_NODE_NEED_STR-NEED06 sy-vline
WA_WCS_SP_WP_NODE_NEED_STR-NEED07 sy-vline
WA_WCS_SP_WP_NODE_NEED_STR-NEED08 sy-vline
WA_WCS_SP_WP_NODE_NEED_STR-NEED09 sy-vline
WA_WCS_SP_WP_NODE_NEED_STR-NEED10 sy-vline
WA_WCS_SP_WP_NODE_NEED_STR-NEED11 sy-vline
WA_WCS_SP_WP_NODE_NEED_STR-NEED12 sy-vline
WA_WCS_SP_WP_NODE_NEED_STR-NEED13 sy-vline
WA_WCS_SP_WP_NODE_NEED_STR-NEED14 sy-vline
WA_WCS_SP_WP_NODE_NEED_STR-NEED15 sy-vline
WA_WCS_SP_WP_NODE_NEED_STR-NEED16 sy-vline
WA_WCS_SP_WP_NODE_NEED_STR-NEED17 sy-vline
WA_WCS_SP_WP_NODE_NEED_STR-NEED18 sy-vline
WA_WCS_SP_WP_NODE_NEED_STR-NEED19 sy-vline
WA_WCS_SP_WP_NODE_NEED_STR-NEED20 sy-vline
WA_WCS_SP_WP_NODE_NEED_STR-NEED21 sy-vline
WA_WCS_SP_WP_NODE_NEED_STR-NEED22 sy-vline
WA_WCS_SP_WP_NODE_NEED_STR-NEED23 sy-vline
WA_WCS_SP_WP_NODE_NEED_STR-NEED24 sy-vline
WA_WCS_SP_WP_NODE_NEED_STR-NEED25 sy-vline
WA_WCS_SP_WP_NODE_NEED_STR-NEED26 sy-vline
WA_WCS_SP_WP_NODE_NEED_STR-NEED27 sy-vline
WA_WCS_SP_WP_NODE_NEED_STR-NEED28 sy-vline
WA_WCS_SP_WP_NODE_NEED_STR-EDITABLE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.