ABAP Select data from SAP table WCS_SP_SCT_NODE_ASGN_WRKPRMT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP WCS_SP_SCT_NODE_ASGN_WRKPRMT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to WCS_SP_SCT_NODE_ASGN_WRKPRMT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the WCS_SP_SCT_NODE_ASGN_WRKPRMT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_WCS_SP_SCT_NODE_ASGN_WRKPRMT TYPE STANDARD TABLE OF WCS_SP_SCT_NODE_ASGN_WRKPRMT,
      WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT TYPE WCS_SP_SCT_NODE_ASGN_WRKPRMT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <WCS_SP_SCT_NODE_ASGN_WRKPRMT> TYPE WCS_SP_SCT_NODE_ASGN_WRKPRMT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_WCS_SP_SCT_NODE_ASGN_WRKPRMT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM WCS_SP_SCT_NODE_ASGN_WRKPRMT
  INTO TABLE IT_WCS_SP_SCT_NODE_ASGN_WRKPRMT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM WCS_SP_SCT_NODE_ASGN_WRKPRMT
*  INTO TABLE @DATA(IT_WCS_SP_SCT_NODE_ASGN_WRKPRMT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_WCS_SP_SCT_NODE_ASGN_WRKPRMT INDEX 1 INTO DATA(WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_WCS_SP_SCT_NODE_ASGN_WRKPRMT ASSIGNING <WCS_SP_SCT_NODE_ASGN_WRKPRMT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<WCS_SP_SCT_NODE_ASGN_WRKPRMT>-EAMS_OBJNR = 1.
<WCS_SP_SCT_NODE_ASGN_WRKPRMT>-IWERK = 1.
<WCS_SP_SCT_NODE_ASGN_WRKPRMT>-WAPITYP = 1.
<WCS_SP_SCT_NODE_ASGN_WRKPRMT>-USECTRL = 1.
<WCS_SP_SCT_NODE_ASGN_WRKPRMT>-IWERK_TEXT = 1.
ENDLOOP.

LOOP AT IT_WCS_SP_SCT_NODE_ASGN_WRKPRMT INTO WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT-WAPITYP_TEXT, sy-vline,
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT-WAPINR, sy-vline,
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT-WAPIUSE, sy-vline,
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT-WAPIUSE_TEXT, sy-vline,
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT-OBJNR, sy-vline,
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT-STXT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_WCS_SP_SCT_NODE_ASGN_WRKPRMT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_WCS_SP_SCT_NODE_ASGN_WRKPRMT INTO WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field WAPINR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT-WAPINR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT-WAPINR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field TPLNR CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT-TPLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT-TPLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EAMS_EQUNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT-EAMS_EQUNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT-EAMS_EQUNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR,
EAMS_OBJNR TYPE STRING,
IWERK TYPE STRING,
WAPITYP TYPE STRING,
USECTRL TYPE STRING,
IWERK_TEXT TYPE STRING,
WAPITYP_TEXT TYPE STRING,
WAPINR TYPE STRING,
WAPIUSE TYPE STRING,
WAPIUSE_TEXT TYPE STRING,
OBJNR TYPE STRING,
STXT TYPE STRING,
PRIOK TYPE STRING,
PRIOK_TEXT TYPE STRING,
DATEFR TYPE STRING,
TIMEFR TYPE STRING,
DATETO TYPE STRING,
TIMETO TYPE STRING,
CRNAME TYPE STRING,
CRDATE TYPE STRING,
CRTIME TYPE STRING,
CHNAME TYPE STRING,
CHDATE TYPE STRING,
CHTIME TYPE STRING,
SYSSTFLG TYPE STRING,
CREA TYPE STRING,
PREP TYPE STRING,
CHGN TYPE STRING,
PWP TYPE STRING,
WPHO TYPE STRING,
CLSD TYPE STRING,
REJC TYPE STRING,
INAK TYPE STRING,
DLFL TYPE STRING,
TENT TYPE STRING,
MOBI TYPE STRING,
SYSST TYPE STRING,
USRST TYPE STRING,
TLCNT_ICON TYPE STRING,
TLCNT_TEXT TYPE STRING,
LCPHASE_ICON TYPE STRING,
LCPHASE_TEXT TYPE STRING,
EAMS_TEC_OBJ_TYPE TYPE STRING,
EAMS_TEC_OBJ_NO TYPE STRING,
EAMS_TEC_OBJ_TYPE_TXT TYPE STRING,
EAMS_TEC_OBJ_TEXT TYPE STRING,
TPLNR TYPE STRING,
EAMS_EQUNR TYPE STRING,
EDITABLE TYPE STRING,END OF T_EKKO_STR. DATA: WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-EAMS_OBJNR sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-IWERK sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-WAPITYP sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-USECTRL sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-IWERK_TEXT sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-WAPITYP_TEXT sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-WAPINR sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-WAPIUSE sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-WAPIUSE_TEXT sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-OBJNR sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-STXT sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-PRIOK sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-PRIOK_TEXT sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-DATEFR sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-TIMEFR sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-DATETO sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-TIMETO sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-CRNAME sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-CRDATE sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-CRTIME sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-CHNAME sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-CHDATE sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-CHTIME sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-SYSSTFLG sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-CREA sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-PREP sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-CHGN sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-PWP sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-WPHO sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-CLSD sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-REJC sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-INAK sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-DLFL sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-TENT sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-MOBI sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-SYSST sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-USRST sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-TLCNT_ICON sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-TLCNT_TEXT sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-LCPHASE_ICON sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-LCPHASE_TEXT sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-EAMS_TEC_OBJ_TYPE sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-EAMS_TEC_OBJ_NO sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-EAMS_TEC_OBJ_TYPE_TXT sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-EAMS_TEC_OBJ_TEXT sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-TPLNR sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-EAMS_EQUNR sy-vline
WA_WCS_SP_SCT_NODE_ASGN_WRKPRMT_STR-EDITABLE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.