ABAP Select data from SAP table WCONDINT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP WCONDINT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to WCONDINT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the WCONDINT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_WCONDINT TYPE STANDARD TABLE OF WCONDINT,
      WA_WCONDINT TYPE WCONDINT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <WCONDINT> TYPE WCONDINT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_WCONDINT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM WCONDINT
  INTO TABLE IT_WCONDINT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM WCONDINT
*  INTO TABLE @DATA(IT_WCONDINT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_WCONDINT INDEX 1 INTO DATA(WA_WCONDINT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_WCONDINT ASSIGNING <WCONDINT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<WCONDINT>-KSCHL = 1.
<WCONDINT>-KOTABNR = 1.
<WCONDINT>-DATAB = 1.
<WCONDINT>-DATBI = 1.
<WCONDINT>-KNUMH = 1.
ENDLOOP.

LOOP AT IT_WCONDINT INTO WA_WCONDINT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_WCONDINT-VKORG, sy-vline,
WA_WCONDINT-VTWEG, sy-vline,
WA_WCONDINT-WERKS, sy-vline,
WA_WCONDINT-PLTYP, sy-vline,
WA_WCONDINT-KUNNR, sy-vline,
WA_WCONDINT-MATNR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_WCONDINT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_WCONDINT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_WCONDINT INTO WA_WCONDINT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit KOTAB, internal->external for field KOTABNR CALL FUNCTION 'CONVERSION_EXIT_KOTAB_OUTPUT' EXPORTING input = WA_WCONDINT-KOTABNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WCONDINT-KOTABNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KUNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WCONDINT-KUNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WCONDINT-KUNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_WCONDINT-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WCONDINT-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VRKME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_WCONDINT-VRKME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WCONDINT-VRKME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EAN11, internal->external for field EAN11 CALL FUNCTION 'CONVERSION_EXIT_EAN11_OUTPUT' EXPORTING input = WA_WCONDINT-EAN11 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WCONDINT-EAN11.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AKTNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WCONDINT-AKTNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WCONDINT-AKTNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_WCONDINT_STR,
KSCHL TYPE STRING,
KOTABNR TYPE STRING,
DATAB TYPE STRING,
DATBI TYPE STRING,
KNUMH TYPE STRING,
VKORG TYPE STRING,
VTWEG TYPE STRING,
WERKS TYPE STRING,
PLTYP TYPE STRING,
KUNNR TYPE STRING,
MATNR TYPE STRING,
VRKME TYPE STRING,
EAN11 TYPE STRING,
WAERK TYPE STRING,
AKTNR TYPE STRING,END OF T_EKKO_STR. DATA: WA_WCONDINT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_WCONDINT_STR-KSCHL sy-vline
WA_WCONDINT_STR-KOTABNR sy-vline
WA_WCONDINT_STR-DATAB sy-vline
WA_WCONDINT_STR-DATBI sy-vline
WA_WCONDINT_STR-KNUMH sy-vline
WA_WCONDINT_STR-VKORG sy-vline
WA_WCONDINT_STR-VTWEG sy-vline
WA_WCONDINT_STR-WERKS sy-vline
WA_WCONDINT_STR-PLTYP sy-vline
WA_WCONDINT_STR-KUNNR sy-vline
WA_WCONDINT_STR-MATNR sy-vline
WA_WCONDINT_STR-VRKME sy-vline
WA_WCONDINT_STR-EAN11 sy-vline
WA_WCONDINT_STR-WAERK sy-vline
WA_WCONDINT_STR-AKTNR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.