ABAP Select data from SAP table WB2B_VC_TC_VCSD_UPD into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP WB2B_VC_TC_VCSD_UPD table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to WB2B_VC_TC_VCSD_UPD. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the WB2B_VC_TC_VCSD_UPD table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_WB2B_VC_TC_VCSD_UPD TYPE STANDARD TABLE OF WB2B_VC_TC_VCSD_UPD, WA_WB2B_VC_TC_VCSD_UPD TYPE WB2B_VC_TC_VCSD_UPD, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <WB2B_VC_TC_VCSD_UPD> TYPE WB2B_VC_TC_VCSD_UPD. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_WB2B_VC_TC_VCSD_UPD. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM WB2B_VC_TC_VCSD_UPD INTO TABLE IT_WB2B_VC_TC_VCSD_UPD. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM WB2B_VC_TC_VCSD_UPD * INTO TABLE @DATA(IT_WB2B_VC_TC_VCSD_UPD2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_WB2B_VC_TC_VCSD_UPD INDEX 1 INTO DATA(WA_WB2B_VC_TC_VCSD_UPD2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_WB2B_VC_TC_VCSD_UPD ASSIGNING <WB2B_VC_TC_VCSD_UPD>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<WB2B_VC_TC_VCSD_UPD>-TKONN = 1.
<WB2B_VC_TC_VCSD_UPD>-TPOSN = 1.
<WB2B_VC_TC_VCSD_UPD>-BRGEW = 1.
<WB2B_VC_TC_VCSD_UPD>-AUT_BRGEW = 1.
<WB2B_VC_TC_VCSD_UPD>-BRGEW_MM = 1.
ENDLOOP. LOOP AT IT_WB2B_VC_TC_VCSD_UPD INTO WA_WB2B_VC_TC_VCSD_UPD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_WB2B_VC_TC_VCSD_UPD-AUT_BRGEW_MM, sy-vline,
WA_WB2B_VC_TC_VCSD_UPD-NTGEW, sy-vline,
WA_WB2B_VC_TC_VCSD_UPD-AUT_NTGEW, sy-vline,
WA_WB2B_VC_TC_VCSD_UPD-NTGEW_MM, sy-vline,
WA_WB2B_VC_TC_VCSD_UPD-AUT_NTGEW_MM, sy-vline,
WA_WB2B_VC_TC_VCSD_UPD-GEWEI, sy-vline.
ENDLOOP. *Add any further fields from structure WA_WB2B_VC_TC_VCSD_UPD you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_WB2B_VC_TC_VCSD_UPD TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_WB2B_VC_TC_VCSD_UPD INTO WA_WB2B_VC_TC_VCSD_UPD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field TKONN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_WB2B_VC_TC_VCSD_UPD-TKONN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WB2B_VC_TC_VCSD_UPD-TKONN.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field GEWEI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_WB2B_VC_TC_VCSD_UPD-GEWEI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WB2B_VC_TC_VCSD_UPD-GEWEI.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field VOLEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_WB2B_VC_TC_VCSD_UPD-VOLEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WB2B_VC_TC_VCSD_UPD-VOLEH.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field VRKME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_WB2B_VC_TC_VCSD_UPD-VRKME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WB2B_VC_TC_VCSD_UPD-VRKME.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_WB2B_VC_TC_VCSD_UPD-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WB2B_VC_TC_VCSD_UPD-MEINS.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field BPRME_MM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_WB2B_VC_TC_VCSD_UPD-BPRME_MM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_WB2B_VC_TC_VCSD_UPD-BPRME_MM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_WB2B_VC_TC_VCSD_UPD_STR,
TKONN TYPE STRING,
TPOSN TYPE STRING,
BRGEW TYPE STRING,
AUT_BRGEW TYPE STRING,
BRGEW_MM TYPE STRING,
AUT_BRGEW_MM TYPE STRING,
NTGEW TYPE STRING,
AUT_NTGEW TYPE STRING,
NTGEW_MM TYPE STRING,
AUT_NTGEW_MM TYPE STRING,
GEWEI TYPE STRING,
AUT_GEWEI TYPE STRING,
VOLUM TYPE STRING,
AUT_VOLUM TYPE STRING,
VOLUM_MM TYPE STRING,
AUT_VOLUM_MM TYPE STRING,
VOLEH TYPE STRING,
AUT_VOLEH TYPE STRING,
KWMENG TYPE STRING,
AUT_KWMENG TYPE STRING,
MENGE TYPE STRING,
AUT_MENGE TYPE STRING,
VRKME TYPE STRING,
AUT_VRKME TYPE STRING,
MEINS TYPE STRING,
AUT_MEINS TYPE STRING,
UMVKZ TYPE STRING,
AUT_UMVKZ TYPE STRING,
UMREZ_MM TYPE STRING,
AUT_UMREZ_MM TYPE STRING,
UMVKN TYPE STRING,
AUT_UMVKN TYPE STRING,
UMREN_MM TYPE STRING,
AUT_UMREN_MM TYPE STRING,
BPRME_MM TYPE STRING,
AUT_BPRME_MM TYPE STRING,
BPUMZ_MM TYPE STRING,
AUT_BPUMZ_MM TYPE STRING,
BPUMN_MM TYPE STRING,
AUT_BPUMN_MM TYPE STRING,
ARKTX TYPE STRING,
AUT_ARKTX TYPE STRING,END OF T_EKKO_STR. DATA: WA_WB2B_VC_TC_VCSD_UPD_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_WB2B_VC_TC_VCSD_UPD_STR-TKONN sy-vline
WA_WB2B_VC_TC_VCSD_UPD_STR-TPOSN sy-vline
WA_WB2B_VC_TC_VCSD_UPD_STR-BRGEW sy-vline
WA_WB2B_VC_TC_VCSD_UPD_STR-AUT_BRGEW sy-vline
WA_WB2B_VC_TC_VCSD_UPD_STR-BRGEW_MM sy-vline
WA_WB2B_VC_TC_VCSD_UPD_STR-AUT_BRGEW_MM sy-vline
WA_WB2B_VC_TC_VCSD_UPD_STR-NTGEW sy-vline
WA_WB2B_VC_TC_VCSD_UPD_STR-AUT_NTGEW sy-vline
WA_WB2B_VC_TC_VCSD_UPD_STR-NTGEW_MM sy-vline
WA_WB2B_VC_TC_VCSD_UPD_STR-AUT_NTGEW_MM sy-vline
WA_WB2B_VC_TC_VCSD_UPD_STR-GEWEI sy-vline
WA_WB2B_VC_TC_VCSD_UPD_STR-AUT_GEWEI sy-vline
WA_WB2B_VC_TC_VCSD_UPD_STR-VOLUM sy-vline
WA_WB2B_VC_TC_VCSD_UPD_STR-AUT_VOLUM sy-vline
WA_WB2B_VC_TC_VCSD_UPD_STR-VOLUM_MM sy-vline
WA_WB2B_VC_TC_VCSD_UPD_STR-AUT_VOLUM_MM sy-vline
WA_WB2B_VC_TC_VCSD_UPD_STR-VOLEH sy-vline
WA_WB2B_VC_TC_VCSD_UPD_STR-AUT_VOLEH sy-vline
WA_WB2B_VC_TC_VCSD_UPD_STR-KWMENG sy-vline
WA_WB2B_VC_TC_VCSD_UPD_STR-AUT_KWMENG sy-vline
WA_WB2B_VC_TC_VCSD_UPD_STR-MENGE sy-vline
WA_WB2B_VC_TC_VCSD_UPD_STR-AUT_MENGE sy-vline
WA_WB2B_VC_TC_VCSD_UPD_STR-VRKME sy-vline
WA_WB2B_VC_TC_VCSD_UPD_STR-AUT_VRKME sy-vline
WA_WB2B_VC_TC_VCSD_UPD_STR-MEINS sy-vline
WA_WB2B_VC_TC_VCSD_UPD_STR-AUT_MEINS sy-vline
WA_WB2B_VC_TC_VCSD_UPD_STR-UMVKZ sy-vline
WA_WB2B_VC_TC_VCSD_UPD_STR-AUT_UMVKZ sy-vline
WA_WB2B_VC_TC_VCSD_UPD_STR-UMREZ_MM sy-vline
WA_WB2B_VC_TC_VCSD_UPD_STR-AUT_UMREZ_MM sy-vline
WA_WB2B_VC_TC_VCSD_UPD_STR-UMVKN sy-vline
WA_WB2B_VC_TC_VCSD_UPD_STR-AUT_UMVKN sy-vline
WA_WB2B_VC_TC_VCSD_UPD_STR-UMREN_MM sy-vline
WA_WB2B_VC_TC_VCSD_UPD_STR-AUT_UMREN_MM sy-vline
WA_WB2B_VC_TC_VCSD_UPD_STR-BPRME_MM sy-vline
WA_WB2B_VC_TC_VCSD_UPD_STR-AUT_BPRME_MM sy-vline
WA_WB2B_VC_TC_VCSD_UPD_STR-BPUMZ_MM sy-vline
WA_WB2B_VC_TC_VCSD_UPD_STR-AUT_BPUMZ_MM sy-vline
WA_WB2B_VC_TC_VCSD_UPD_STR-BPUMN_MM sy-vline
WA_WB2B_VC_TC_VCSD_UPD_STR-AUT_BPUMN_MM sy-vline
WA_WB2B_VC_TC_VCSD_UPD_STR-ARKTX sy-vline
WA_WB2B_VC_TC_VCSD_UPD_STR-AUT_ARKTX sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.