ABAP Select data from SAP table W3MINX into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP W3MINX table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to W3MINX. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the W3MINX table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_W3MINX TYPE STANDARD TABLE OF W3MINX,
      WA_W3MINX TYPE W3MINX,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <W3MINX> TYPE W3MINX.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_W3MINX.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM W3MINX
  INTO TABLE IT_W3MINX.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM W3MINX
*  INTO TABLE @DATA(IT_W3MINX2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_W3MINX INDEX 1 INTO DATA(WA_W3MINX2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_W3MINX ASSIGNING <W3MINX>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<W3MINX>-APPNAME = 1.
<W3MINX>-SRV_FILE = 1.
<W3MINX>-APPNAMEV = 1.
<W3MINX>-APPTYPE = 1.
<W3MINX>-IMPTYPE = 1.
ENDLOOP.

LOOP AT IT_W3MINX INTO WA_W3MINX.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_W3MINX-INITPAGE, sy-vline,
WA_W3MINX-URLCOMPO1, sy-vline,
WA_W3MINX-URLCOMPO2, sy-vline,
WA_W3MINX-URLCOMPO3, sy-vline,
WA_W3MINX-URLCOMPO4, sy-vline,
WA_W3MINX-URLCOMPO5, sy-vline.
ENDLOOP. *Add any further fields from structure WA_W3MINX you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_W3MINX TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_W3MINX INTO WA_W3MINX. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_W3MINX_STR,
APPNAME TYPE STRING,
SRV_FILE TYPE STRING,
APPNAMEV TYPE STRING,
APPTYPE TYPE STRING,
IMPTYPE TYPE STRING,
INITPAGE TYPE STRING,
URLCOMPO1 TYPE STRING,
URLCOMPO2 TYPE STRING,
URLCOMPO3 TYPE STRING,
URLCOMPO4 TYPE STRING,
URLCOMPO5 TYPE STRING,
URLCOMPO6 TYPE STRING,
URLCOMPO7 TYPE STRING,
URLCOMPO8 TYPE STRING,
THEME TYPE STRING,
PERSMIN TYPE STRING,
PERVASIVE TYPE STRING,
REFRESH TYPE STRING,
REFR_TIME TYPE STRING,
HEIGHT TYPE STRING,
WIDTH TYPE STRING,
STATLINE TYPE STRING,END OF T_EKKO_STR. DATA: WA_W3MINX_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_W3MINX_STR-APPNAME sy-vline
WA_W3MINX_STR-SRV_FILE sy-vline
WA_W3MINX_STR-APPNAMEV sy-vline
WA_W3MINX_STR-APPTYPE sy-vline
WA_W3MINX_STR-IMPTYPE sy-vline
WA_W3MINX_STR-INITPAGE sy-vline
WA_W3MINX_STR-URLCOMPO1 sy-vline
WA_W3MINX_STR-URLCOMPO2 sy-vline
WA_W3MINX_STR-URLCOMPO3 sy-vline
WA_W3MINX_STR-URLCOMPO4 sy-vline
WA_W3MINX_STR-URLCOMPO5 sy-vline
WA_W3MINX_STR-URLCOMPO6 sy-vline
WA_W3MINX_STR-URLCOMPO7 sy-vline
WA_W3MINX_STR-URLCOMPO8 sy-vline
WA_W3MINX_STR-THEME sy-vline
WA_W3MINX_STR-PERSMIN sy-vline
WA_W3MINX_STR-PERVASIVE sy-vline
WA_W3MINX_STR-REFRESH sy-vline
WA_W3MINX_STR-REFR_TIME sy-vline
WA_W3MINX_STR-HEIGHT sy-vline
WA_W3MINX_STR-WIDTH sy-vline
WA_W3MINX_STR-STATLINE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.