ABAP Select data from SAP table VZBAVV into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP VZBAVV table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VZBAVV. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the VZBAVV table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_VZBAVV TYPE STANDARD TABLE OF VZBAVV,
      WA_VZBAVV TYPE VZBAVV,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <VZBAVV> TYPE VZBAVV.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_VZBAVV.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM VZBAVV
  INTO TABLE IT_VZBAVV.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM VZBAVV
*  INTO TABLE @DATA(IT_VZBAVV2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_VZBAVV INDEX 1 INTO DATA(WA_VZBAVV2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_VZBAVV ASSIGNING <VZBAVV>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<VZBAVV>-MANDT = 1.
<VZBAVV>-RANTYP = 1.
<VZBAVV>-VVKEY = 1.
<VZBAVV>-DGUEL_AB = 1.
<VZBAVV>-SUDEC = 1.
ENDLOOP.

LOOP AT IT_VZBAVV INTO WA_VZBAVV.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_VZBAVV-SSKZB, sy-vline,
WA_VZBAVV-SDVNR, sy-vline,
WA_VZBAVV-SUABNDV, sy-vline,
WA_VZBAVV-SOEFFKL, sy-vline,
WA_VZBAVV-RINUM, sy-vline,
WA_VZBAVV-SSKZF, sy-vline.
ENDLOOP. *Add any further fields from structure WA_VZBAVV you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VZBAVV TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VZBAVV INTO WA_VZBAVV. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field VVKEY CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VZBAVV-VVKEY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VZBAVV-VVKEY.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VZBAVV_STR,
MANDT TYPE STRING,
RANTYP TYPE STRING,
VVKEY TYPE STRING,
DGUEL_AB TYPE STRING,
SUDEC TYPE STRING,
SSKZB TYPE STRING,
SDVNR TYPE STRING,
SUABNDV TYPE STRING,
SOEFFKL TYPE STRING,
RINUM TYPE STRING,
SSKZF TYPE STRING,
RINUMH TYPE STRING,
RERF TYPE STRING,
DAEND TYPE STRING,
TAEND TYPE STRING,
SANLART TYPE STRING,
BARWBAV TYPE STRING,
SAWHR TYPE STRING,
BVWERT TYPE STRING,
SVWHR TYPE STRING,
BARW_VU TYPE STRING,
SAWHR_VU TYPE STRING,
SAART TYPE STRING,
SDV TYPE STRING,
SUABT TYPE STRING,
SMWWHR TYPE STRING,
SNW600 TYPE STRING,END OF T_EKKO_STR. DATA: WA_VZBAVV_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VZBAVV_STR-MANDT sy-vline
WA_VZBAVV_STR-RANTYP sy-vline
WA_VZBAVV_STR-VVKEY sy-vline
WA_VZBAVV_STR-DGUEL_AB sy-vline
WA_VZBAVV_STR-SUDEC sy-vline
WA_VZBAVV_STR-SSKZB sy-vline
WA_VZBAVV_STR-SDVNR sy-vline
WA_VZBAVV_STR-SUABNDV sy-vline
WA_VZBAVV_STR-SOEFFKL sy-vline
WA_VZBAVV_STR-RINUM sy-vline
WA_VZBAVV_STR-SSKZF sy-vline
WA_VZBAVV_STR-RINUMH sy-vline
WA_VZBAVV_STR-RERF sy-vline
WA_VZBAVV_STR-DAEND sy-vline
WA_VZBAVV_STR-TAEND sy-vline
WA_VZBAVV_STR-SANLART sy-vline
WA_VZBAVV_STR-BARWBAV sy-vline
WA_VZBAVV_STR-SAWHR sy-vline
WA_VZBAVV_STR-BVWERT sy-vline
WA_VZBAVV_STR-SVWHR sy-vline
WA_VZBAVV_STR-BARW_VU sy-vline
WA_VZBAVV_STR-SAWHR_VU sy-vline
WA_VZBAVV_STR-SAART sy-vline
WA_VZBAVV_STR-SDV sy-vline
WA_VZBAVV_STR-SUABT sy-vline
WA_VZBAVV_STR-SMWWHR sy-vline
WA_VZBAVV_STR-SNW600 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.