ABAP Select data from SAP table VWB2_D_STRING_H into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP VWB2_D_STRING_H table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VWB2_D_STRING_H. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the VWB2_D_STRING_H table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_VWB2_D_STRING_H TYPE STANDARD TABLE OF VWB2_D_STRING_H,
      WA_VWB2_D_STRING_H TYPE VWB2_D_STRING_H,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <VWB2_D_STRING_H> TYPE VWB2_D_STRING_H.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_VWB2_D_STRING_H.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM VWB2_D_STRING_H
  INTO TABLE IT_VWB2_D_STRING_H.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM VWB2_D_STRING_H
*  INTO TABLE @DATA(IT_VWB2_D_STRING_H2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_VWB2_D_STRING_H INDEX 1 INTO DATA(WA_VWB2_D_STRING_H2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_VWB2_D_STRING_H ASSIGNING <VWB2_D_STRING_H>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<VWB2_D_STRING_H>-CLIENT = 1.
<VWB2_D_STRING_H>-TKONN = 1.
<VWB2_D_STRING_H>-NETPR = 1.
<VWB2_D_STRING_H>-CURR = 1.
<VWB2_D_STRING_H>-COND_UNIT = 1.
ENDLOOP.

LOOP AT IT_VWB2_D_STRING_H INTO WA_VWB2_D_STRING_H.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_VWB2_D_STRING_H-PRICING_UNIT, sy-vline,
WA_VWB2_D_STRING_H-MATNR, sy-vline,
WA_VWB2_D_STRING_H-WASHED_QUAN, sy-vline,
WA_VWB2_D_STRING_H-WASHED_QUAN_UNIT, sy-vline,
WA_VWB2_D_STRING_H-FROZEN, sy-vline,
WA_VWB2_D_STRING_H-CHAIN_STATUS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_VWB2_D_STRING_H you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VWB2_D_STRING_H TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VWB2_D_STRING_H INTO WA_VWB2_D_STRING_H. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field TKONN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VWB2_D_STRING_H-TKONN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VWB2_D_STRING_H-TKONN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field COND_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_VWB2_D_STRING_H-COND_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VWB2_D_STRING_H-COND_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_VWB2_D_STRING_H-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VWB2_D_STRING_H-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field WASHED_QUAN_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_VWB2_D_STRING_H-WASHED_QUAN_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VWB2_D_STRING_H-WASHED_QUAN_UNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VWB2_D_STRING_H_STR,
CLIENT TYPE STRING,
TKONN TYPE STRING,
NETPR TYPE STRING,
CURR TYPE STRING,
COND_UNIT TYPE STRING,
PRICING_UNIT TYPE STRING,
MATNR TYPE STRING,
WASHED_QUAN TYPE STRING,
WASHED_QUAN_UNIT TYPE STRING,
FROZEN TYPE STRING,
CHAIN_STATUS TYPE STRING,
COMPANY_CODE TYPE STRING,
_DATAAGING TYPE STRING,
KZ TYPE STRING,END OF T_EKKO_STR. DATA: WA_VWB2_D_STRING_H_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VWB2_D_STRING_H_STR-CLIENT sy-vline
WA_VWB2_D_STRING_H_STR-TKONN sy-vline
WA_VWB2_D_STRING_H_STR-NETPR sy-vline
WA_VWB2_D_STRING_H_STR-CURR sy-vline
WA_VWB2_D_STRING_H_STR-COND_UNIT sy-vline
WA_VWB2_D_STRING_H_STR-PRICING_UNIT sy-vline
WA_VWB2_D_STRING_H_STR-MATNR sy-vline
WA_VWB2_D_STRING_H_STR-WASHED_QUAN sy-vline
WA_VWB2_D_STRING_H_STR-WASHED_QUAN_UNIT sy-vline
WA_VWB2_D_STRING_H_STR-FROZEN sy-vline
WA_VWB2_D_STRING_H_STR-CHAIN_STATUS sy-vline
WA_VWB2_D_STRING_H_STR-COMPANY_CODE sy-vline
WA_VWB2_D_STRING_H_STR-_DATAAGING sy-vline
WA_VWB2_D_STRING_H_STR-KZ sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.