ABAP Select data from SAP table VVSCPOSWH into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP VVSCPOSWH table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VVSCPOSWH. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the VVSCPOSWH table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_VVSCPOSWH TYPE STANDARD TABLE OF VVSCPOSWH,
      WA_VVSCPOSWH TYPE VVSCPOSWH,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <VVSCPOSWH> TYPE VVSCPOSWH.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_VVSCPOSWH.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM VVSCPOSWH
  INTO TABLE IT_VVSCPOSWH.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM VVSCPOSWH
*  INTO TABLE @DATA(IT_VVSCPOSWH2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_VVSCPOSWH INDEX 1 INTO DATA(WA_VVSCPOSWH2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_VVSCPOSWH ASSIGNING <VVSCPOSWH>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<VVSCPOSWH>-MANDT = 1.
<VVSCPOSWH>-GPART = 1.
<VVSCPOSWH>-VTREF = 1.
<VVSCPOSWH>-POSNR = 1.
<VVSCPOSWH>-SCPOSNR = 1.
ENDLOOP.

LOOP AT IT_VVSCPOSWH INTO WA_VVSCPOSWH.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_VVSCPOSWH-QSSEW, sy-vline,
WA_VVSCPOSWH-STPRZ, sy-vline,
WA_VVSCPOSWH-QSSHB, sy-vline,
WA_VVSCPOSWH-QBSHB, sy-vline,
WA_VVSCPOSWH-QSSHB_TRANS, sy-vline,
WA_VVSCPOSWH-QBSHB_TRANS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_VVSCPOSWH you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VVSCPOSWH TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VVSCPOSWH INTO WA_VVSCPOSWH. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field GPART CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VVSCPOSWH-GPART IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VVSCPOSWH-GPART.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VTREF CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VVSCPOSWH-VTREF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VVSCPOSWH-VTREF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field POSNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VVSCPOSWH-POSNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VVSCPOSWH-POSNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VVSCPOSWH_STR,
MANDT TYPE STRING,
GPART TYPE STRING,
VTREF TYPE STRING,
POSNR TYPE STRING,
SCPOSNR TYPE STRING,
QSSEW TYPE STRING,
STPRZ TYPE STRING,
QSSHB TYPE STRING,
QBSHB TYPE STRING,
QSSHB_TRANS TYPE STRING,
QBSHB_TRANS TYPE STRING,END OF T_EKKO_STR. DATA: WA_VVSCPOSWH_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VVSCPOSWH_STR-MANDT sy-vline
WA_VVSCPOSWH_STR-GPART sy-vline
WA_VVSCPOSWH_STR-VTREF sy-vline
WA_VVSCPOSWH_STR-POSNR sy-vline
WA_VVSCPOSWH_STR-SCPOSNR sy-vline
WA_VVSCPOSWH_STR-QSSEW sy-vline
WA_VVSCPOSWH_STR-STPRZ sy-vline
WA_VVSCPOSWH_STR-QSSHB sy-vline
WA_VVSCPOSWH_STR-QBSHB sy-vline
WA_VVSCPOSWH_STR-QSSHB_TRANS sy-vline
WA_VVSCPOSWH_STR-QBSHB_TRANS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.