ABAP Select data from SAP table VV_T685H_WM into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP VV_T685H_WM table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VV_T685H_WM. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the VV_T685H_WM table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_VV_T685H_WM TYPE STANDARD TABLE OF VV_T685H_WM,
      WA_VV_T685H_WM TYPE VV_T685H_WM,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <VV_T685H_WM> TYPE VV_T685H_WM.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_VV_T685H_WM.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM VV_T685H_WM
  INTO TABLE IT_VV_T685H_WM.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM VV_T685H_WM
*  INTO TABLE @DATA(IT_VV_T685H_WM2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_VV_T685H_WM INDEX 1 INTO DATA(WA_VV_T685H_WM2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_VV_T685H_WM ASSIGNING <VV_T685H_WM>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<VV_T685H_WM>-MANDT = 1.
<VV_T685H_WM>-KVEWE = 1.
<VV_T685H_WM>-KAPPL = 1.
<VV_T685H_WM>-KSCHL = 1.
<VV_T685H_WM>-KOZGF = 1.
ENDLOOP.

LOOP AT IT_VV_T685H_WM INTO WA_VV_T685H_WM.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_VV_T685H_WM-DATVO, sy-vline,
WA_VV_T685H_WM-DTVOB, sy-vline,
WA_VV_T685H_WM-CHSPL, sy-vline,
WA_VV_T685H_WM-CHANZ, sy-vline,
WA_VV_T685H_WM-CHASP, sy-vline,
WA_VV_T685H_WM-CHMDG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_VV_T685H_WM you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VV_T685H_WM TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VV_T685H_WM INTO WA_VV_T685H_WM. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VV_T685H_WM_STR,
MANDT TYPE STRING,
KVEWE TYPE STRING,
KAPPL TYPE STRING,
KSCHL TYPE STRING,
KOZGF TYPE STRING,
DATVO TYPE STRING,
DTVOB TYPE STRING,
CHSPL TYPE STRING,
CHANZ TYPE STRING,
CHASP TYPE STRING,
CHMDG TYPE STRING,
CHMVS TYPE STRING,
CHMAN TYPE STRING,
KZAME TYPE STRING,
CHDYN TYPE STRING,
CHCUA TYPE STRING,
CLINT_SEL TYPE STRING,
CLINT_SRT TYPE STRING,
CHVSK TYPE STRING,
CHVLL TYPE STRING,
CLASS_SEL TYPE STRING,
CLASS_SRT TYPE STRING,
VTEXT TYPE STRING,END OF T_EKKO_STR. DATA: WA_VV_T685H_WM_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VV_T685H_WM_STR-MANDT sy-vline
WA_VV_T685H_WM_STR-KVEWE sy-vline
WA_VV_T685H_WM_STR-KAPPL sy-vline
WA_VV_T685H_WM_STR-KSCHL sy-vline
WA_VV_T685H_WM_STR-KOZGF sy-vline
WA_VV_T685H_WM_STR-DATVO sy-vline
WA_VV_T685H_WM_STR-DTVOB sy-vline
WA_VV_T685H_WM_STR-CHSPL sy-vline
WA_VV_T685H_WM_STR-CHANZ sy-vline
WA_VV_T685H_WM_STR-CHASP sy-vline
WA_VV_T685H_WM_STR-CHMDG sy-vline
WA_VV_T685H_WM_STR-CHMVS sy-vline
WA_VV_T685H_WM_STR-CHMAN sy-vline
WA_VV_T685H_WM_STR-KZAME sy-vline
WA_VV_T685H_WM_STR-CHDYN sy-vline
WA_VV_T685H_WM_STR-CHCUA sy-vline
WA_VV_T685H_WM_STR-CLINT_SEL sy-vline
WA_VV_T685H_WM_STR-CLINT_SRT sy-vline
WA_VV_T685H_WM_STR-CHVSK sy-vline
WA_VV_T685H_WM_STR-CHVLL sy-vline
WA_VV_T685H_WM_STR-CLASS_SEL sy-vline
WA_VV_T685H_WM_STR-CLASS_SRT sy-vline
WA_VV_T685H_WM_STR-VTEXT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.