ABAP Select data from SAP table VV_T5DF6_A_FR into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP VV_T5DF6_A_FR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VV_T5DF6_A_FR. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the VV_T5DF6_A_FR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_VV_T5DF6_A_FR TYPE STANDARD TABLE OF VV_T5DF6_A_FR, WA_VV_T5DF6_A_FR TYPE VV_T5DF6_A_FR, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <VV_T5DF6_A_FR> TYPE VV_T5DF6_A_FR. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_VV_T5DF6_A_FR. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM VV_T5DF6_A_FR INTO TABLE IT_VV_T5DF6_A_FR. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM VV_T5DF6_A_FR * INTO TABLE @DATA(IT_VV_T5DF6_A_FR2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_VV_T5DF6_A_FR INDEX 1 INTO DATA(WA_VV_T5DF6_A_FR2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_VV_T5DF6_A_FR ASSIGNING <VV_T5DF6_A_FR>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<VV_T5DF6_A_FR>-MANDT = 1.
<VV_T5DF6_A_FR>-BEWID = 1.
<VV_T5DF6_A_FR>-BSUBJ = 1.
<VV_T5DF6_A_FR>-SPONAM = 1.
<VV_T5DF6_A_FR>-SUFFX1 = 1.
ENDLOOP. LOOP AT IT_VV_T5DF6_A_FR INTO WA_VV_T5DF6_A_FR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_VV_T5DF6_A_FR-SUFFX2, sy-vline,
WA_VV_T5DF6_A_FR-COPNR, sy-vline,
WA_VV_T5DF6_A_FR-AUTH, sy-vline,
WA_VV_T5DF6_A_FR-BEWTX, sy-vline,
WA_VV_T5DF6_A_FR-BSBTX, sy-vline,
WA_VV_T5DF6_A_FR-MOLGA, sy-vline.
ENDLOOP. *Add any further fields from structure WA_VV_T5DF6_A_FR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VV_T5DF6_A_FR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VV_T5DF6_A_FR INTO WA_VV_T5DF6_A_FR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VV_T5DF6_A_FR_STR,
MANDT TYPE STRING,
BEWID TYPE STRING,
BSUBJ TYPE STRING,
SPONAM TYPE STRING,
SUFFX1 TYPE STRING,
SUFFX2 TYPE STRING,
COPNR TYPE STRING,
AUTH TYPE STRING,
BEWTX TYPE STRING,
BSBTX TYPE STRING,
MOLGA TYPE STRING,END OF T_EKKO_STR. DATA: WA_VV_T5DF6_A_FR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VV_T5DF6_A_FR_STR-MANDT sy-vline
WA_VV_T5DF6_A_FR_STR-BEWID sy-vline
WA_VV_T5DF6_A_FR_STR-BSUBJ sy-vline
WA_VV_T5DF6_A_FR_STR-SPONAM sy-vline
WA_VV_T5DF6_A_FR_STR-SUFFX1 sy-vline
WA_VV_T5DF6_A_FR_STR-SUFFX2 sy-vline
WA_VV_T5DF6_A_FR_STR-COPNR sy-vline
WA_VV_T5DF6_A_FR_STR-AUTH sy-vline
WA_VV_T5DF6_A_FR_STR-BEWTX sy-vline
WA_VV_T5DF6_A_FR_STR-BSBTX sy-vline
WA_VV_T5DF6_A_FR_STR-MOLGA sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.