ABAP Select data from SAP table VV_T549S_01_AL0_11 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP VV_T549S_01_AL0_11 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VV_T549S_01_AL0_11. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the VV_T549S_01_AL0_11 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_VV_T549S_01_AL0_11 TYPE STANDARD TABLE OF VV_T549S_01_AL0_11, WA_VV_T549S_01_AL0_11 TYPE VV_T549S_01_AL0_11, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <VV_T549S_01_AL0_11> TYPE VV_T549S_01_AL0_11. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_VV_T549S_01_AL0_11. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM VV_T549S_01_AL0_11 INTO TABLE IT_VV_T549S_01_AL0_11. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM VV_T549S_01_AL0_11 * INTO TABLE @DATA(IT_VV_T549S_01_AL0_112). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_VV_T549S_01_AL0_11 INDEX 1 INTO DATA(WA_VV_T549S_01_AL0_112). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_VV_T549S_01_AL0_11 ASSIGNING <VV_T549S_01_AL0_11>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<VV_T549S_01_AL0_11>-MANDT = 1.
<VV_T549S_01_AL0_11>-MOLGA = 1.
<VV_T549S_01_AL0_11>-DATMO = 1.
<VV_T549S_01_AL0_11>-PERMO = 1.
<VV_T549S_01_AL0_11>-PABRJ = 1.
ENDLOOP. LOOP AT IT_VV_T549S_01_AL0_11 INTO WA_VV_T549S_01_AL0_11. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_VV_T549S_01_AL0_11-PABRP, sy-vline,
WA_VV_T549S_01_AL0_11-DATID, sy-vline,
WA_VV_T549S_01_AL0_11-ATEXT, sy-vline,
WA_VV_T549S_01_AL0_11-LTEXT, sy-vline,
WA_VV_T549S_01_AL0_11-PDATE, sy-vline,
ENDLOOP. *Add any further fields from structure WA_VV_T549S_01_AL0_11 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VV_T549S_01_AL0_11 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VV_T549S_01_AL0_11 INTO WA_VV_T549S_01_AL0_11. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit GJAHR, internal->external for field PABRJ CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_VV_T549S_01_AL0_11-PABRJ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VV_T549S_01_AL0_11-PABRJ.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VV_T549S_01_AL0_11_STR,
MANDT TYPE STRING,
MOLGA TYPE STRING,
DATMO TYPE STRING,
PERMO TYPE STRING,
PABRJ TYPE STRING,
PABRP TYPE STRING,
DATID TYPE STRING,
ATEXT TYPE STRING,
LTEXT TYPE STRING,
PDATE TYPE STRING,END OF T_EKKO_STR. DATA: WA_VV_T549S_01_AL0_11_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VV_T549S_01_AL0_11_STR-MANDT sy-vline
WA_VV_T549S_01_AL0_11_STR-MOLGA sy-vline
WA_VV_T549S_01_AL0_11_STR-DATMO sy-vline
WA_VV_T549S_01_AL0_11_STR-PERMO sy-vline
WA_VV_T549S_01_AL0_11_STR-PABRJ sy-vline
WA_VV_T549S_01_AL0_11_STR-PABRP sy-vline
WA_VV_T549S_01_AL0_11_STR-DATID sy-vline
WA_VV_T549S_01_AL0_11_STR-ATEXT sy-vline
WA_VV_T549S_01_AL0_11_STR-LTEXT sy-vline
WA_VV_T549S_01_AL0_11_STR-PDATE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.