ABAP Select data from SAP table VV_CACS_CASSGN into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP VV_CACS_CASSGN table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VV_CACS_CASSGN. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the VV_CACS_CASSGN table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_VV_CACS_CASSGN TYPE STANDARD TABLE OF VV_CACS_CASSGN,
      WA_VV_CACS_CASSGN TYPE VV_CACS_CASSGN,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <VV_CACS_CASSGN> TYPE VV_CACS_CASSGN.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_VV_CACS_CASSGN.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM VV_CACS_CASSGN
  INTO TABLE IT_VV_CACS_CASSGN.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM VV_CACS_CASSGN
*  INTO TABLE @DATA(IT_VV_CACS_CASSGN2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_VV_CACS_CASSGN INDEX 1 INTO DATA(WA_VV_CACS_CASSGN2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_VV_CACS_CASSGN ASSIGNING <VV_CACS_CASSGN>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<VV_CACS_CASSGN>-MANDT = 1.
<VV_CACS_CASSGN>-APPL = 1.
<VV_CACS_CASSGN>-COMBTP_ID = 1.
<VV_CACS_CASSGN>-TABNAME = 1.
<VV_CACS_CASSGN>-SEL_ID = 1.
ENDLOOP.

LOOP AT IT_VV_CACS_CASSGN INTO WA_VV_CACS_CASSGN.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_VV_CACS_CASSGN-CTRT_TYPE, sy-vline,
WA_VV_CACS_CASSGN-CTRTST_ID, sy-vline,
WA_VV_CACS_CASSGN-VERSION, sy-vline,
WA_VV_CACS_CASSGN-PL_SEL_ID, sy-vline,
WA_VV_CACS_CASSGN-BUSI_BEGIN, sy-vline,
WA_VV_CACS_CASSGN-BUSI_END, sy-vline.
ENDLOOP. *Add any further fields from structure WA_VV_CACS_CASSGN you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VV_CACS_CASSGN TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VV_CACS_CASSGN INTO WA_VV_CACS_CASSGN. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field COMBTP_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VV_CACS_CASSGN-COMBTP_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VV_CACS_CASSGN-COMBTP_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CTRTST_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VV_CACS_CASSGN-CTRTST_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VV_CACS_CASSGN-CTRTST_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field BUSI_BEGIN CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_VV_CACS_CASSGN-BUSI_BEGIN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VV_CACS_CASSGN-BUSI_BEGIN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field BUSI_END CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_VV_CACS_CASSGN-BUSI_END IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VV_CACS_CASSGN-BUSI_END.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field COMBTP2_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VV_CACS_CASSGN-COMBTP2_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VV_CACS_CASSGN-COMBTP2_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field TECH_BEGIN CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_VV_CACS_CASSGN-TECH_BEGIN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VV_CACS_CASSGN-TECH_BEGIN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field TECH_END CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_VV_CACS_CASSGN-TECH_END IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VV_CACS_CASSGN-TECH_END.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VV_CACS_CASSGN_STR,
MANDT TYPE STRING,
APPL TYPE STRING,
COMBTP_ID TYPE STRING,
TABNAME TYPE STRING,
SEL_ID TYPE STRING,
CTRT_TYPE TYPE STRING,
CTRTST_ID TYPE STRING,
VERSION TYPE STRING,
PL_SEL_ID TYPE STRING,
BUSI_BEGIN TYPE STRING,
BUSI_END TYPE STRING,
COMBTP2_ID TYPE STRING,
FLG_CANCEL_VERS TYPE STRING,
FLG_CANCEL_OBJ TYPE STRING,
TECH_BEGIN TYPE STRING,
TECH_END TYPE STRING,
CHG_TCODE TYPE STRING,
CHG_USR TYPE STRING,
TRI_METH_TYP TYPE STRING,
TRI_METH_TARGET TYPE STRING,
STATUS_VERSION TYPE STRING,
STATUS_WORK TYPE STRING,END OF T_EKKO_STR. DATA: WA_VV_CACS_CASSGN_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VV_CACS_CASSGN_STR-MANDT sy-vline
WA_VV_CACS_CASSGN_STR-APPL sy-vline
WA_VV_CACS_CASSGN_STR-COMBTP_ID sy-vline
WA_VV_CACS_CASSGN_STR-TABNAME sy-vline
WA_VV_CACS_CASSGN_STR-SEL_ID sy-vline
WA_VV_CACS_CASSGN_STR-CTRT_TYPE sy-vline
WA_VV_CACS_CASSGN_STR-CTRTST_ID sy-vline
WA_VV_CACS_CASSGN_STR-VERSION sy-vline
WA_VV_CACS_CASSGN_STR-PL_SEL_ID sy-vline
WA_VV_CACS_CASSGN_STR-BUSI_BEGIN sy-vline
WA_VV_CACS_CASSGN_STR-BUSI_END sy-vline
WA_VV_CACS_CASSGN_STR-COMBTP2_ID sy-vline
WA_VV_CACS_CASSGN_STR-FLG_CANCEL_VERS sy-vline
WA_VV_CACS_CASSGN_STR-FLG_CANCEL_OBJ sy-vline
WA_VV_CACS_CASSGN_STR-TECH_BEGIN sy-vline
WA_VV_CACS_CASSGN_STR-TECH_END sy-vline
WA_VV_CACS_CASSGN_STR-CHG_TCODE sy-vline
WA_VV_CACS_CASSGN_STR-CHG_USR sy-vline
WA_VV_CACS_CASSGN_STR-TRI_METH_TYP sy-vline
WA_VV_CACS_CASSGN_STR-TRI_METH_TARGET sy-vline
WA_VV_CACS_CASSGN_STR-STATUS_VERSION sy-vline
WA_VV_CACS_CASSGN_STR-STATUS_WORK sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.