ABAP Select data from SAP table VSPRTE_CN into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP VSPRTE_CN table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VSPRTE_CN. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the VSPRTE_CN table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_VSPRTE_CN TYPE STANDARD TABLE OF VSPRTE_CN,
      WA_VSPRTE_CN TYPE VSPRTE_CN,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <VSPRTE_CN> TYPE VSPRTE_CN.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_VSPRTE_CN.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM VSPRTE_CN
  INTO TABLE IT_VSPRTE_CN.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM VSPRTE_CN
*  INTO TABLE @DATA(IT_VSPRTE_CN2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_VSPRTE_CN INDEX 1 INTO DATA(WA_VSPRTE_CN2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_VSPRTE_CN ASSIGNING <VSPRTE_CN>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<VSPRTE_CN>-MANDT = 1.
<VSPRTE_CN>-VSNMR = 1.
<VSPRTE_CN>-POSNR = 1.
<VSPRTE_CN>-PSPHI = 1.
<VSPRTE_CN>-PSTRT = 1.
ENDLOOP.

LOOP AT IT_VSPRTE_CN INTO WA_VSPRTE_CN.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_VSPRTE_CN-ESTRT, sy-vline,
WA_VSPRTE_CN-ISTRT, sy-vline,
WA_VSPRTE_CN-PENDE, sy-vline,
WA_VSPRTE_CN-EENDE, sy-vline,
WA_VSPRTE_CN-IENDE, sy-vline,
WA_VSPRTE_CN-PDAUR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_VSPRTE_CN you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VSPRTE_CN TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VSPRTE_CN INTO WA_VSPRTE_CN. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ABPSP, internal->external for field POSNR CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_VSPRTE_CN-POSNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VSPRTE_CN-POSNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit KONPD, internal->external for field PSPHI CALL FUNCTION 'CONVERSION_EXIT_KONPD_OUTPUT' EXPORTING input = WA_VSPRTE_CN-PSPHI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VSPRTE_CN-PSPHI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field IEINH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_VSPRTE_CN-IEINH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VSPRTE_CN-IEINH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field EEINH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_VSPRTE_CN-EEINH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VSPRTE_CN-EEINH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PEINH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_VSPRTE_CN-PEINH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VSPRTE_CN-PEINH.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VSPRTE_CN_STR,
MANDT TYPE STRING,
VSNMR TYPE STRING,
POSNR TYPE STRING,
PSPHI TYPE STRING,
PSTRT TYPE STRING,
ESTRT TYPE STRING,
ISTRT TYPE STRING,
PENDE TYPE STRING,
EENDE TYPE STRING,
IENDE TYPE STRING,
PDAUR TYPE STRING,
EDAUR TYPE STRING,
IDAUR TYPE STRING,
IEINH TYPE STRING,
EEINH TYPE STRING,
PEINH TYPE STRING,
FLGVG TYPE STRING,
FLGEW TYPE STRING,
FLGEM TYPE STRING,
FLGVM TYPE STRING,
FLGIM TYPE STRING,
FLGVI TYPE STRING,
PSTRM TYPE STRING,
PETRM TYPE STRING,
ESTRM TYPE STRING,
EETRM TYPE STRING,
VISTR TYPE STRING,
VIEND TYPE STRING,
PSTRS TYPE STRING,
PETRF TYPE STRING,
ESTRS TYPE STRING,
EETRF TYPE STRING,END OF T_EKKO_STR. DATA: WA_VSPRTE_CN_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VSPRTE_CN_STR-MANDT sy-vline
WA_VSPRTE_CN_STR-VSNMR sy-vline
WA_VSPRTE_CN_STR-POSNR sy-vline
WA_VSPRTE_CN_STR-PSPHI sy-vline
WA_VSPRTE_CN_STR-PSTRT sy-vline
WA_VSPRTE_CN_STR-ESTRT sy-vline
WA_VSPRTE_CN_STR-ISTRT sy-vline
WA_VSPRTE_CN_STR-PENDE sy-vline
WA_VSPRTE_CN_STR-EENDE sy-vline
WA_VSPRTE_CN_STR-IENDE sy-vline
WA_VSPRTE_CN_STR-PDAUR sy-vline
WA_VSPRTE_CN_STR-EDAUR sy-vline
WA_VSPRTE_CN_STR-IDAUR sy-vline
WA_VSPRTE_CN_STR-IEINH sy-vline
WA_VSPRTE_CN_STR-EEINH sy-vline
WA_VSPRTE_CN_STR-PEINH sy-vline
WA_VSPRTE_CN_STR-FLGVG sy-vline
WA_VSPRTE_CN_STR-FLGEW sy-vline
WA_VSPRTE_CN_STR-FLGEM sy-vline
WA_VSPRTE_CN_STR-FLGVM sy-vline
WA_VSPRTE_CN_STR-FLGIM sy-vline
WA_VSPRTE_CN_STR-FLGVI sy-vline
WA_VSPRTE_CN_STR-PSTRM sy-vline
WA_VSPRTE_CN_STR-PETRM sy-vline
WA_VSPRTE_CN_STR-ESTRM sy-vline
WA_VSPRTE_CN_STR-EETRM sy-vline
WA_VSPRTE_CN_STR-VISTR sy-vline
WA_VSPRTE_CN_STR-VIEND sy-vline
WA_VSPRTE_CN_STR-PSTRS sy-vline
WA_VSPRTE_CN_STR-PETRF sy-vline
WA_VSPRTE_CN_STR-ESTRS sy-vline
WA_VSPRTE_CN_STR-EETRF sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.