ABAP Select data from SAP table VSPICSPRTR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP VSPICSPRTR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VSPICSPRTR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the VSPICSPRTR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_VSPICSPRTR TYPE STANDARD TABLE OF VSPICSPRTR,
      WA_VSPICSPRTR TYPE VSPICSPRTR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <VSPICSPRTR> TYPE VSPICSPRTR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_VSPICSPRTR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM VSPICSPRTR
  INTO TABLE IT_VSPICSPRTR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM VSPICSPRTR
*  INTO TABLE @DATA(IT_VSPICSPRTR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_VSPICSPRTR INDEX 1 INTO DATA(WA_VSPICSPRTR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_VSPICSPRTR ASSIGNING <VSPICSPRTR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<VSPICSPRTR>-CLIENT = 1.
<VSPICSPRTR>-PROCTYPE = 1.
<VSPICSPRTR>-PRGUID = 1.
<VSPICSPRTR>-TRGUID = 1.
<VSPICSPRTR>-PRSTEPID = 1.
ENDLOOP.

LOOP AT IT_VSPICSPRTR INTO WA_VSPICSPRTR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_VSPICSPRTR-PERROR, sy-vline,
WA_VSPICSPRTR-CMPFIN, sy-vline,
WA_VSPICSPRTR-CREATIME, sy-vline,
WA_VSPICSPRTR-PBEGIN, sy-vline,
WA_VSPICSPRTR-PEND, sy-vline,
WA_VSPICSPRTR-PDURATION, sy-vline.
ENDLOOP. *Add any further fields from structure WA_VSPICSPRTR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VSPICSPRTR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VSPICSPRTR INTO WA_VSPICSPRTR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VSPICSPRTR-LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VSPICSPRTR-LOGSYS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VSPICSPRTR_STR,
CLIENT TYPE STRING,
PROCTYPE TYPE STRING,
PRGUID TYPE STRING,
TRGUID TYPE STRING,
PRSTEPID TYPE STRING,
PERROR TYPE STRING,
CMPFIN TYPE STRING,
CREATIME TYPE STRING,
PBEGIN TYPE STRING,
PEND TYPE STRING,
PDURATION TYPE STRING,
LOGSYS TYPE STRING,
LOCSYSID TYPE STRING,
LOCCLIENT TYPE STRING,
TCODE TYPE STRING,
REPORT TYPE STRING,
DYNPRONR TYPE STRING,
USERNAME TYPE STRING,
TERMINAL TYPE STRING,
TRANSID TYPE STRING,
WPID TYPE STRING,
HOSTIPADR TYPE STRING,
TIMESTAMP TYPE STRING,
SERROR TYPE STRING,
PREDECID TYPE STRING,
VBKEY TYPE STRING,
CID TYPE STRING,
CWCNT TYPE STRING,
BRANCHID TYPE STRING,
SUPBRANCH TYPE STRING,
SUCCEDID TYPE STRING,
AGGRTIME TYPE STRING,
EXPIRYDATE TYPE STRING,
SCREATIME TYPE STRING,
FINISH TYPE STRING,
PROTECTED TYPE STRING,
ORIGTIME TYPE STRING,END OF T_EKKO_STR. DATA: WA_VSPICSPRTR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VSPICSPRTR_STR-CLIENT sy-vline
WA_VSPICSPRTR_STR-PROCTYPE sy-vline
WA_VSPICSPRTR_STR-PRGUID sy-vline
WA_VSPICSPRTR_STR-TRGUID sy-vline
WA_VSPICSPRTR_STR-PRSTEPID sy-vline
WA_VSPICSPRTR_STR-PERROR sy-vline
WA_VSPICSPRTR_STR-CMPFIN sy-vline
WA_VSPICSPRTR_STR-CREATIME sy-vline
WA_VSPICSPRTR_STR-PBEGIN sy-vline
WA_VSPICSPRTR_STR-PEND sy-vline
WA_VSPICSPRTR_STR-PDURATION sy-vline
WA_VSPICSPRTR_STR-LOGSYS sy-vline
WA_VSPICSPRTR_STR-LOCSYSID sy-vline
WA_VSPICSPRTR_STR-LOCCLIENT sy-vline
WA_VSPICSPRTR_STR-TCODE sy-vline
WA_VSPICSPRTR_STR-REPORT sy-vline
WA_VSPICSPRTR_STR-DYNPRONR sy-vline
WA_VSPICSPRTR_STR-USERNAME sy-vline
WA_VSPICSPRTR_STR-TERMINAL sy-vline
WA_VSPICSPRTR_STR-TRANSID sy-vline
WA_VSPICSPRTR_STR-WPID sy-vline
WA_VSPICSPRTR_STR-HOSTIPADR sy-vline
WA_VSPICSPRTR_STR-TIMESTAMP sy-vline
WA_VSPICSPRTR_STR-SERROR sy-vline
WA_VSPICSPRTR_STR-PREDECID sy-vline
WA_VSPICSPRTR_STR-VBKEY sy-vline
WA_VSPICSPRTR_STR-CID sy-vline
WA_VSPICSPRTR_STR-CWCNT sy-vline
WA_VSPICSPRTR_STR-BRANCHID sy-vline
WA_VSPICSPRTR_STR-SUPBRANCH sy-vline
WA_VSPICSPRTR_STR-SUCCEDID sy-vline
WA_VSPICSPRTR_STR-AGGRTIME sy-vline
WA_VSPICSPRTR_STR-EXPIRYDATE sy-vline
WA_VSPICSPRTR_STR-SCREATIME sy-vline
WA_VSPICSPRTR_STR-FINISH sy-vline
WA_VSPICSPRTR_STR-PROTECTED sy-vline
WA_VSPICSPRTR_STR-ORIGTIME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.