ABAP Select data from SAP table VQMFE_AFFCTD_OBJ into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP VQMFE_AFFCTD_OBJ table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VQMFE_AFFCTD_OBJ. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the VQMFE_AFFCTD_OBJ table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_VQMFE_AFFCTD_OBJ TYPE STANDARD TABLE OF VQMFE_AFFCTD_OBJ,
      WA_VQMFE_AFFCTD_OBJ TYPE VQMFE_AFFCTD_OBJ,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <VQMFE_AFFCTD_OBJ> TYPE VQMFE_AFFCTD_OBJ.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_VQMFE_AFFCTD_OBJ.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM VQMFE_AFFCTD_OBJ
  INTO TABLE IT_VQMFE_AFFCTD_OBJ.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM VQMFE_AFFCTD_OBJ
*  INTO TABLE @DATA(IT_VQMFE_AFFCTD_OBJ2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_VQMFE_AFFCTD_OBJ INDEX 1 INTO DATA(WA_VQMFE_AFFCTD_OBJ2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_VQMFE_AFFCTD_OBJ ASSIGNING <VQMFE_AFFCTD_OBJ>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<VQMFE_AFFCTD_OBJ>-CLIENT = 1.
<VQMFE_AFFCTD_OBJ>-QMNUM = 1.
<VQMFE_AFFCTD_OBJ>-FENUM = 1.
<VQMFE_AFFCTD_OBJ>-OBJCOUNTER = 1.
<VQMFE_AFFCTD_OBJ>-OBJTYPE = 1.
ENDLOOP.

LOOP AT IT_VQMFE_AFFCTD_OBJ INTO WA_VQMFE_AFFCTD_OBJ.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_VQMFE_AFFCTD_OBJ-MATERIAL, sy-vline,
WA_VQMFE_AFFCTD_OBJ-QUANTITY, sy-vline,
WA_VQMFE_AFFCTD_OBJ-QUANTITYUNIT, sy-vline,
WA_VQMFE_AFFCTD_OBJ-BATCH, sy-vline,
WA_VQMFE_AFFCTD_OBJ-DUMMY_QMFE_AFFCTD_INCL_EEW_PS, sy-vline,
WA_VQMFE_AFFCTD_OBJ-KZ, sy-vline.
ENDLOOP. *Add any further fields from structure WA_VQMFE_AFFCTD_OBJ you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VQMFE_AFFCTD_OBJ TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VQMFE_AFFCTD_OBJ INTO WA_VQMFE_AFFCTD_OBJ. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field QMNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VQMFE_AFFCTD_OBJ-QMNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VQMFE_AFFCTD_OBJ-QMNUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_VQMFE_AFFCTD_OBJ-MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VQMFE_AFFCTD_OBJ-MATERIAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field QUANTITYUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_VQMFE_AFFCTD_OBJ-QUANTITYUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VQMFE_AFFCTD_OBJ-QUANTITYUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VQMFE_AFFCTD_OBJ_STR,
CLIENT TYPE STRING,
QMNUM TYPE STRING,
FENUM TYPE STRING,
OBJCOUNTER TYPE STRING,
OBJTYPE TYPE STRING,
MATERIAL TYPE STRING,
QUANTITY TYPE STRING,
QUANTITYUNIT TYPE STRING,
BATCH TYPE STRING,
DUMMY_QMFE_AFFCTD_INCL_EEW_PS TYPE STRING,
KZ TYPE STRING,END OF T_EKKO_STR. DATA: WA_VQMFE_AFFCTD_OBJ_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VQMFE_AFFCTD_OBJ_STR-CLIENT sy-vline
WA_VQMFE_AFFCTD_OBJ_STR-QMNUM sy-vline
WA_VQMFE_AFFCTD_OBJ_STR-FENUM sy-vline
WA_VQMFE_AFFCTD_OBJ_STR-OBJCOUNTER sy-vline
WA_VQMFE_AFFCTD_OBJ_STR-OBJTYPE sy-vline
WA_VQMFE_AFFCTD_OBJ_STR-MATERIAL sy-vline
WA_VQMFE_AFFCTD_OBJ_STR-QUANTITY sy-vline
WA_VQMFE_AFFCTD_OBJ_STR-QUANTITYUNIT sy-vline
WA_VQMFE_AFFCTD_OBJ_STR-BATCH sy-vline
WA_VQMFE_AFFCTD_OBJ_STR-DUMMY_QMFE_AFFCTD_INCL_EEW_PS sy-vline
WA_VQMFE_AFFCTD_OBJ_STR-KZ sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.