ABAP Select data from SAP table VPPHDDMRPSDSTCK into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP VPPHDDMRPSDSTCK table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VPPHDDMRPSDSTCK. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the VPPHDDMRPSDSTCK table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_VPPHDDMRPSDSTCK TYPE STANDARD TABLE OF VPPHDDMRPSDSTCK,
      WA_VPPHDDMRPSDSTCK TYPE VPPHDDMRPSDSTCK,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <VPPHDDMRPSDSTCK> TYPE VPPHDDMRPSDSTCK.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_VPPHDDMRPSDSTCK.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM VPPHDDMRPSDSTCK
  INTO TABLE IT_VPPHDDMRPSDSTCK.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM VPPHDDMRPSDSTCK
*  INTO TABLE @DATA(IT_VPPHDDMRPSDSTCK2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_VPPHDDMRPSDSTCK INDEX 1 INTO DATA(WA_VPPHDDMRPSDSTCK2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_VPPHDDMRPSDSTCK ASSIGNING <VPPHDDMRPSDSTCK>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<VPPHDDMRPSDSTCK>-MANDT = 1.
<VPPHDDMRPSDSTCK>-MATNR = 1.
<VPPHDDMRPSDSTCK>-WERKS = 1.
<VPPHDDMRPSDSTCK>-BERID = 1.
<VPPHDDMRPSDSTCK>-POSTINGDATE = 1.
ENDLOOP.

LOOP AT IT_VPPHDDMRPSDSTCK INTO WA_VPPHDDMRPSDSTCK.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_VPPHDDMRPSDSTCK-PLAAB, sy-vline,
WA_VPPHDDMRPSDSTCK-PLANR, sy-vline,
WA_VPPHDDMRPSDSTCK-SGT_SCAT, sy-vline,
WA_VPPHDDMRPSDSTCK-SORT1, sy-vline,
WA_VPPHDDMRPSDSTCK-SORT2, sy-vline,
WA_VPPHDDMRPSDSTCK-DELKZ, sy-vline.
ENDLOOP. *Add any further fields from structure WA_VPPHDDMRPSDSTCK you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VPPHDDMRPSDSTCK TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VPPHDDMRPSDSTCK INTO WA_VPPHDDMRPSDSTCK. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_VPPHDDMRPSDSTCK-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VPPHDDMRPSDSTCK-MATNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VPPHDDMRPSDSTCK_STR,
MANDT TYPE STRING,
MATNR TYPE STRING,
WERKS TYPE STRING,
BERID TYPE STRING,
POSTINGDATE TYPE STRING,
PLAAB TYPE STRING,
PLANR TYPE STRING,
SGT_SCAT TYPE STRING,
SORT1 TYPE STRING,
SORT2 TYPE STRING,
DELKZ TYPE STRING,
SOBKZ TYPE STRING,
LIFNR TYPE STRING,
KDAUF TYPE STRING,
KDPOS TYPE STRING,
PSPEL TYPE STRING,
VRFKZ TYPE STRING,
PLUMI TYPE STRING,
MNG01 TYPE STRING,
MNG01C TYPE STRING,END OF T_EKKO_STR. DATA: WA_VPPHDDMRPSDSTCK_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VPPHDDMRPSDSTCK_STR-MANDT sy-vline
WA_VPPHDDMRPSDSTCK_STR-MATNR sy-vline
WA_VPPHDDMRPSDSTCK_STR-WERKS sy-vline
WA_VPPHDDMRPSDSTCK_STR-BERID sy-vline
WA_VPPHDDMRPSDSTCK_STR-POSTINGDATE sy-vline
WA_VPPHDDMRPSDSTCK_STR-PLAAB sy-vline
WA_VPPHDDMRPSDSTCK_STR-PLANR sy-vline
WA_VPPHDDMRPSDSTCK_STR-SGT_SCAT sy-vline
WA_VPPHDDMRPSDSTCK_STR-SORT1 sy-vline
WA_VPPHDDMRPSDSTCK_STR-SORT2 sy-vline
WA_VPPHDDMRPSDSTCK_STR-DELKZ sy-vline
WA_VPPHDDMRPSDSTCK_STR-SOBKZ sy-vline
WA_VPPHDDMRPSDSTCK_STR-LIFNR sy-vline
WA_VPPHDDMRPSDSTCK_STR-KDAUF sy-vline
WA_VPPHDDMRPSDSTCK_STR-KDPOS sy-vline
WA_VPPHDDMRPSDSTCK_STR-PSPEL sy-vline
WA_VPPHDDMRPSDSTCK_STR-VRFKZ sy-vline
WA_VPPHDDMRPSDSTCK_STR-PLUMI sy-vline
WA_VPPHDDMRPSDSTCK_STR-MNG01 sy-vline
WA_VPPHDDMRPSDSTCK_STR-MNG01C sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.