ABAP Select data from SAP table VOTIV24 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP VOTIV24 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VOTIV24. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the VOTIV24 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_VOTIV24 TYPE STANDARD TABLE OF VOTIV24,
      WA_VOTIV24 TYPE VOTIV24,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <VOTIV24> TYPE VOTIV24.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_VOTIV24.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM VOTIV24
  INTO TABLE IT_VOTIV24.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM VOTIV24
*  INTO TABLE @DATA(IT_VOTIV242).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_VOTIV24 INDEX 1 INTO DATA(WA_VOTIV242).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_VOTIV24 ASSIGNING <VOTIV24>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<VOTIV24>-MANDT = 1.
<VOTIV24>-SMIETSP = 1.
<VOTIV24>-SMKLASS = 1.
<VOTIV24>-SNUMM = 1.
<VOTIV24>-FFLVO = 1.
ENDLOOP.

LOOP AT IT_VOTIV24 INTO WA_VOTIV24.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_VOTIV24-FFLBI, sy-vline,
WA_VOTIV24-BPRMER, sy-vline,
WA_VOTIV24-AMAX, sy-vline,
WA_VOTIV24-BMAXB, sy-vline,
WA_VOTIV24-BPKTFL, sy-vline,
WA_VOTIV24-PPROZ, sy-vline.
ENDLOOP. *Add any further fields from structure WA_VOTIV24 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VOTIV24 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VOTIV24 INTO WA_VOTIV24. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VOTIV24_STR,
MANDT TYPE STRING,
SMIETSP TYPE STRING,
SMKLASS TYPE STRING,
SNUMM TYPE STRING,
FFLVO TYPE STRING,
FFLBI TYPE STRING,
BPRMER TYPE STRING,
AMAX TYPE STRING,
BMAXB TYPE STRING,
BPKTFL TYPE STRING,
PPROZ TYPE STRING,
PPRMER TYPE STRING,
XLBEZM TYPE STRING,
XLBEZA TYPE STRING,
JGRUND TYPE STRING,
JPUNKTE TYPE STRING,END OF T_EKKO_STR. DATA: WA_VOTIV24_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VOTIV24_STR-MANDT sy-vline
WA_VOTIV24_STR-SMIETSP sy-vline
WA_VOTIV24_STR-SMKLASS sy-vline
WA_VOTIV24_STR-SNUMM sy-vline
WA_VOTIV24_STR-FFLVO sy-vline
WA_VOTIV24_STR-FFLBI sy-vline
WA_VOTIV24_STR-BPRMER sy-vline
WA_VOTIV24_STR-AMAX sy-vline
WA_VOTIV24_STR-BMAXB sy-vline
WA_VOTIV24_STR-BPKTFL sy-vline
WA_VOTIV24_STR-PPROZ sy-vline
WA_VOTIV24_STR-PPRMER sy-vline
WA_VOTIV24_STR-XLBEZM sy-vline
WA_VOTIV24_STR-XLBEZA sy-vline
WA_VOTIV24_STR-JGRUND sy-vline
WA_VOTIV24_STR-JPUNKTE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.