ABAP Select data from SAP table VOPENPOSTGPERIOD into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP VOPENPOSTGPERIOD table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VOPENPOSTGPERIOD. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the VOPENPOSTGPERIOD table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_VOPENPOSTGPERIOD TYPE STANDARD TABLE OF VOPENPOSTGPERIOD,
      WA_VOPENPOSTGPERIOD TYPE VOPENPOSTGPERIOD,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <VOPENPOSTGPERIOD> TYPE VOPENPOSTGPERIOD.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_VOPENPOSTGPERIOD.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM VOPENPOSTGPERIOD
  INTO TABLE IT_VOPENPOSTGPERIOD.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM VOPENPOSTGPERIOD
*  INTO TABLE @DATA(IT_VOPENPOSTGPERIOD2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_VOPENPOSTGPERIOD INDEX 1 INTO DATA(WA_VOPENPOSTGPERIOD2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_VOPENPOSTGPERIOD ASSIGNING <VOPENPOSTGPERIOD>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<VOPENPOSTGPERIOD>-MANDT = 1.
<VOPENPOSTGPERIOD>-COMPANYCODE = 1.
<VOPENPOSTGPERIOD>-LEDGER = 1.
<VOPENPOSTGPERIOD>-BTTYPE = 1.
<VOPENPOSTGPERIOD>-FISCALYEAR = 1.
ENDLOOP.

LOOP AT IT_VOPENPOSTGPERIOD INTO WA_VOPENPOSTGPERIOD.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_VOPENPOSTGPERIOD-FISCALPERIOD, sy-vline,
WA_VOPENPOSTGPERIOD-PERIODSTATUS, sy-vline,
WA_VOPENPOSTGPERIOD-LASTCHANGETIME, sy-vline,
WA_VOPENPOSTGPERIOD-LASTCHANGEDATE, sy-vline,
WA_VOPENPOSTGPERIOD-LASTCHANGEUSER, sy-vline,
WA_VOPENPOSTGPERIOD-KZ, sy-vline.
ENDLOOP. *Add any further fields from structure WA_VOPENPOSTGPERIOD you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VOPENPOSTGPERIOD TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VOPENPOSTGPERIOD INTO WA_VOPENPOSTGPERIOD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field LEDGER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VOPENPOSTGPERIOD-LEDGER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VOPENPOSTGPERIOD-LEDGER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field FISCALYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_VOPENPOSTGPERIOD-FISCALYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VOPENPOSTGPERIOD-FISCALYEAR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VOPENPOSTGPERIOD_STR,
MANDT TYPE STRING,
COMPANYCODE TYPE STRING,
LEDGER TYPE STRING,
BTTYPE TYPE STRING,
FISCALYEAR TYPE STRING,
FISCALPERIOD TYPE STRING,
PERIODSTATUS TYPE STRING,
LASTCHANGETIME TYPE STRING,
LASTCHANGEDATE TYPE STRING,
LASTCHANGEUSER TYPE STRING,
KZ TYPE STRING,END OF T_EKKO_STR. DATA: WA_VOPENPOSTGPERIOD_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VOPENPOSTGPERIOD_STR-MANDT sy-vline
WA_VOPENPOSTGPERIOD_STR-COMPANYCODE sy-vline
WA_VOPENPOSTGPERIOD_STR-LEDGER sy-vline
WA_VOPENPOSTGPERIOD_STR-BTTYPE sy-vline
WA_VOPENPOSTGPERIOD_STR-FISCALYEAR sy-vline
WA_VOPENPOSTGPERIOD_STR-FISCALPERIOD sy-vline
WA_VOPENPOSTGPERIOD_STR-PERIODSTATUS sy-vline
WA_VOPENPOSTGPERIOD_STR-LASTCHANGETIME sy-vline
WA_VOPENPOSTGPERIOD_STR-LASTCHANGEDATE sy-vline
WA_VOPENPOSTGPERIOD_STR-LASTCHANGEUSER sy-vline
WA_VOPENPOSTGPERIOD_STR-KZ sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.