ABAP Select data from SAP table VMP_S_MBOM_IDENT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP VMP_S_MBOM_IDENT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VMP_S_MBOM_IDENT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the VMP_S_MBOM_IDENT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_VMP_S_MBOM_IDENT TYPE STANDARD TABLE OF VMP_S_MBOM_IDENT,
      WA_VMP_S_MBOM_IDENT TYPE VMP_S_MBOM_IDENT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <VMP_S_MBOM_IDENT> TYPE VMP_S_MBOM_IDENT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_VMP_S_MBOM_IDENT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM VMP_S_MBOM_IDENT
  INTO TABLE IT_VMP_S_MBOM_IDENT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM VMP_S_MBOM_IDENT
*  INTO TABLE @DATA(IT_VMP_S_MBOM_IDENT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_VMP_S_MBOM_IDENT INDEX 1 INTO DATA(WA_VMP_S_MBOM_IDENT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_VMP_S_MBOM_IDENT ASSIGNING <VMP_S_MBOM_IDENT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<VMP_S_MBOM_IDENT>-MANDT = 1.
<VMP_S_MBOM_IDENT>-STLTY = 1.
<VMP_S_MBOM_IDENT>-STLNR = 1.
<VMP_S_MBOM_IDENT>-STLAL = 1.
<VMP_S_MBOM_IDENT>-WERKS = 1.
ENDLOOP.

LOOP AT IT_VMP_S_MBOM_IDENT INTO WA_VMP_S_MBOM_IDENT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_VMP_S_MBOM_IDENT-MATNR, sy-vline,
WA_VMP_S_MBOM_IDENT-GUIDX, sy-vline,
WA_VMP_S_MBOM_IDENT-ZTEXT, sy-vline,
WA_VMP_S_MBOM_IDENT-MAKTX, sy-vline,
WA_VMP_S_MBOM_IDENT-STKTX, sy-vline,
WA_VMP_S_MBOM_IDENT-DATUV, sy-vline.
ENDLOOP. *Add any further fields from structure WA_VMP_S_MBOM_IDENT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VMP_S_MBOM_IDENT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VMP_S_MBOM_IDENT INTO WA_VMP_S_MBOM_IDENT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit NUMCV, internal->external for field STLNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_VMP_S_MBOM_IDENT-STLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VMP_S_MBOM_IDENT-STLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field STLAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VMP_S_MBOM_IDENT-STLAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VMP_S_MBOM_IDENT-STLAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN5, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN5_OUTPUT' EXPORTING input = WA_VMP_S_MBOM_IDENT-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VMP_S_MBOM_IDENT-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VMP_S_MBOM_IDENT-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VMP_S_MBOM_IDENT-AENNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR_LONG CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_VMP_S_MBOM_IDENT-MATNR_LONG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VMP_S_MBOM_IDENT-MATNR_LONG.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VMP_S_MBOM_IDENT_STR,
MANDT TYPE STRING,
STLTY TYPE STRING,
STLNR TYPE STRING,
STLAL TYPE STRING,
WERKS TYPE STRING,
MATNR TYPE STRING,
GUIDX TYPE STRING,
ZTEXT TYPE STRING,
MAKTX TYPE STRING,
STKTX TYPE STRING,
DATUV TYPE STRING,
DATUB TYPE STRING,
AENNR TYPE STRING,
MATNR_LONG TYPE STRING,
BOM_VERSN TYPE STRING,
VERSNST TYPE STRING,
VERSNLASTIND TYPE STRING,END OF T_EKKO_STR. DATA: WA_VMP_S_MBOM_IDENT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VMP_S_MBOM_IDENT_STR-MANDT sy-vline
WA_VMP_S_MBOM_IDENT_STR-STLTY sy-vline
WA_VMP_S_MBOM_IDENT_STR-STLNR sy-vline
WA_VMP_S_MBOM_IDENT_STR-STLAL sy-vline
WA_VMP_S_MBOM_IDENT_STR-WERKS sy-vline
WA_VMP_S_MBOM_IDENT_STR-MATNR sy-vline
WA_VMP_S_MBOM_IDENT_STR-GUIDX sy-vline
WA_VMP_S_MBOM_IDENT_STR-ZTEXT sy-vline
WA_VMP_S_MBOM_IDENT_STR-MAKTX sy-vline
WA_VMP_S_MBOM_IDENT_STR-STKTX sy-vline
WA_VMP_S_MBOM_IDENT_STR-DATUV sy-vline
WA_VMP_S_MBOM_IDENT_STR-DATUB sy-vline
WA_VMP_S_MBOM_IDENT_STR-AENNR sy-vline
WA_VMP_S_MBOM_IDENT_STR-MATNR_LONG sy-vline
WA_VMP_S_MBOM_IDENT_STR-BOM_VERSN sy-vline
WA_VMP_S_MBOM_IDENT_STR-VERSNST sy-vline
WA_VMP_S_MBOM_IDENT_STR-VERSNLASTIND sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.