ABAP Select data from SAP table VIVW06 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP VIVW06 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VIVW06. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the VIVW06 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_VIVW06 TYPE STANDARD TABLE OF VIVW06,
      WA_VIVW06 TYPE VIVW06,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <VIVW06> TYPE VIVW06.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_VIVW06.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM VIVW06
  INTO TABLE IT_VIVW06.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM VIVW06
*  INTO TABLE @DATA(IT_VIVW062).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_VIVW06 INDEX 1 INTO DATA(WA_VIVW062).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_VIVW06 ASSIGNING <VIVW06>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<VIVW06>-MANDT = 1.
<VIVW06>-BUKRS = 1.
<VIVW06>-SVWNR = 1.
<VIVW06>-SHOARTEX = 1.
<VIVW06>-DGULTAB = 1.
ENDLOOP.

LOOP AT IT_VIVW06 INTO WA_VIVW06.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_VIVW06-DGULBIS, sy-vline,
WA_VIVW06-JPERIO, sy-vline,
WA_VIVW06-JVZ, sy-vline,
WA_VIVW06-MWSKZ, sy-vline,
WA_VIVW06-JLOESCH, sy-vline,
WA_VIVW06-MWSKZ_VST, sy-vline.
ENDLOOP. *Add any further fields from structure WA_VIVW06 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VIVW06 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VIVW06 INTO WA_VIVW06. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field SVWNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VIVW06-SVWNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIVW06-SVWNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VIVW06_STR,
MANDT TYPE STRING,
BUKRS TYPE STRING,
SVWNR TYPE STRING,
SHOARTEX TYPE STRING,
DGULTAB TYPE STRING,
DGULBIS TYPE STRING,
JPERIO TYPE STRING,
JVZ TYPE STRING,
MWSKZ TYPE STRING,
JLOESCH TYPE STRING,
MWSKZ_VST TYPE STRING,
TXJCD TYPE STRING,
TXJCD_VST TYPE STRING,
NOCORHON TYPE STRING,END OF T_EKKO_STR. DATA: WA_VIVW06_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VIVW06_STR-MANDT sy-vline
WA_VIVW06_STR-BUKRS sy-vline
WA_VIVW06_STR-SVWNR sy-vline
WA_VIVW06_STR-SHOARTEX sy-vline
WA_VIVW06_STR-DGULTAB sy-vline
WA_VIVW06_STR-DGULBIS sy-vline
WA_VIVW06_STR-JPERIO sy-vline
WA_VIVW06_STR-JVZ sy-vline
WA_VIVW06_STR-MWSKZ sy-vline
WA_VIVW06_STR-JLOESCH sy-vline
WA_VIVW06_STR-MWSKZ_VST sy-vline
WA_VIVW06_STR-TXJCD sy-vline
WA_VIVW06_STR-TXJCD_VST sy-vline
WA_VIVW06_STR-NOCORHON sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.