ABAP Select data from SAP table VIMGENCB into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP VIMGENCB table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VIMGENCB. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the VIMGENCB table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_VIMGENCB TYPE STANDARD TABLE OF VIMGENCB,
      WA_VIMGENCB TYPE VIMGENCB,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <VIMGENCB> TYPE VIMGENCB.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_VIMGENCB.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM VIMGENCB
  INTO TABLE IT_VIMGENCB.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM VIMGENCB
*  INTO TABLE @DATA(IT_VIMGENCB2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_VIMGENCB INDEX 1 INTO DATA(WA_VIMGENCB2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_VIMGENCB ASSIGNING <VIMGENCB>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<VIMGENCB>-AREA = 1.
<VIMGENCB>-VIEWNAME = 1.
<VIMGENCB>-CREPOOL = 1.
<VIMGENCB>-CRECUA = 1.
<VIMGENCB>-CRETEXT = 1.
ENDLOOP.

LOOP AT IT_VIMGENCB INTO WA_VIMGENCB.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_VIMGENCB-CREPROG, sy-vline,
WA_VIMGENCB-CRETOP, sy-vline,
WA_VIMGENCB-CREFFUNC, sy-vline,
WA_VIMGENCB-CREPFUNC, sy-vline,
WA_VIMGENCB-CREIMEMB, sy-vline,
WA_VIMGENCB-CRETMEMB, sy-vline.
ENDLOOP. *Add any further fields from structure WA_VIMGENCB you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VIMGENCB TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VIMGENCB INTO WA_VIMGENCB. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VIMGENCB_STR,
AREA TYPE STRING,
VIEWNAME TYPE STRING,
CREPOOL TYPE STRING,
CRECUA TYPE STRING,
CRETEXT TYPE STRING,
CREPROG TYPE STRING,
CRETOP TYPE STRING,
CREFFUNC TYPE STRING,
CREPFUNC TYPE STRING,
CREIMEMB TYPE STRING,
CRETMEMB TYPE STRING,
CREFMEMB TYPE STRING,
CREUFMEMB TYPE STRING,
CREUPMEMB TYPE STRING,
CREDYNP1 TYPE STRING,
CREDYNP2 TYPE STRING,
DELPROG TYPE STRING,
DELCUA TYPE STRING,
DELTOP TYPE STRING,
DELFFUNC TYPE STRING,
DELPFUNC TYPE STRING,
DELIMEMB TYPE STRING,
DELTMEMB TYPE STRING,
DELFMEMB TYPE STRING,
DELUFMEMB TYPE STRING,
DELUPMEMB TYPE STRING,
DELDYNP1 TYPE STRING,
DELDYNP2 TYPE STRING,
DELTVDIR TYPE STRING,
DELOBJECTS TYPE STRING,
POOL TYPE STRING,
CUA TYPE STRING,
TEXT TYPE STRING,
PROG TYPE STRING,
TOP TYPE STRING,
IMEMB TYPE STRING,
TMEMB TYPE STRING,
FMEMB TYPE STRING,
TFFUNC TYPE STRING,
TPFUNC TYPE STRING,
TUFMEMB TYPE STRING,
TUPMEMB TYPE STRING,
FFUNC TYPE STRING,
PFUNC TYPE STRING,
UFMEMB TYPE STRING,
UPMEMB TYPE STRING,
DYNP1 TYPE STRING,
DYNP2 TYPE STRING,
TVDIR TYPE STRING,
REGCUA TYPE STRING,
REGTEXT TYPE STRING,
REGPROG TYPE STRING,
REGTOP TYPE STRING,
REGDYNP1 TYPE STRING,
CORRNO TYPE STRING,
DELPOOL TYPE STRING,
DELVARI TYPE STRING,
DELEVENTS TYPE STRING,
DELAUTGRP TYPE STRING,
RC_POOL TYPE STRING,
RC_PROG TYPE STRING,
RC_TOP TYPE STRING,
RC_IMEMB TYPE STRING,
RC_TMEMB TYPE STRING,
RC_FMEMB TYPE STRING,
RC_TFFUNC TYPE STRING,
RC_TPFUNC TYPE STRING,
RC_TUFMEMB TYPE STRING,
RC_TUPMEMB TYPE STRING,
RC_FFUNC TYPE STRING,
RC_PFUNC TYPE STRING,
RC_UFMEMB TYPE STRING,
RC_UPMEMB TYPE STRING,
RC_DYNP1 TYPE STRING,
RC_DYNP2 TYPE STRING,
RC_TVDIR TYPE STRING,END OF T_EKKO_STR. DATA: WA_VIMGENCB_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VIMGENCB_STR-AREA sy-vline
WA_VIMGENCB_STR-VIEWNAME sy-vline
WA_VIMGENCB_STR-CREPOOL sy-vline
WA_VIMGENCB_STR-CRECUA sy-vline
WA_VIMGENCB_STR-CRETEXT sy-vline
WA_VIMGENCB_STR-CREPROG sy-vline
WA_VIMGENCB_STR-CRETOP sy-vline
WA_VIMGENCB_STR-CREFFUNC sy-vline
WA_VIMGENCB_STR-CREPFUNC sy-vline
WA_VIMGENCB_STR-CREIMEMB sy-vline
WA_VIMGENCB_STR-CRETMEMB sy-vline
WA_VIMGENCB_STR-CREFMEMB sy-vline
WA_VIMGENCB_STR-CREUFMEMB sy-vline
WA_VIMGENCB_STR-CREUPMEMB sy-vline
WA_VIMGENCB_STR-CREDYNP1 sy-vline
WA_VIMGENCB_STR-CREDYNP2 sy-vline
WA_VIMGENCB_STR-DELPROG sy-vline
WA_VIMGENCB_STR-DELCUA sy-vline
WA_VIMGENCB_STR-DELTOP sy-vline
WA_VIMGENCB_STR-DELFFUNC sy-vline
WA_VIMGENCB_STR-DELPFUNC sy-vline
WA_VIMGENCB_STR-DELIMEMB sy-vline
WA_VIMGENCB_STR-DELTMEMB sy-vline
WA_VIMGENCB_STR-DELFMEMB sy-vline
WA_VIMGENCB_STR-DELUFMEMB sy-vline
WA_VIMGENCB_STR-DELUPMEMB sy-vline
WA_VIMGENCB_STR-DELDYNP1 sy-vline
WA_VIMGENCB_STR-DELDYNP2 sy-vline
WA_VIMGENCB_STR-DELTVDIR sy-vline
WA_VIMGENCB_STR-DELOBJECTS sy-vline
WA_VIMGENCB_STR-POOL sy-vline
WA_VIMGENCB_STR-CUA sy-vline
WA_VIMGENCB_STR-TEXT sy-vline
WA_VIMGENCB_STR-PROG sy-vline
WA_VIMGENCB_STR-TOP sy-vline
WA_VIMGENCB_STR-IMEMB sy-vline
WA_VIMGENCB_STR-TMEMB sy-vline
WA_VIMGENCB_STR-FMEMB sy-vline
WA_VIMGENCB_STR-TFFUNC sy-vline
WA_VIMGENCB_STR-TPFUNC sy-vline
WA_VIMGENCB_STR-TUFMEMB sy-vline
WA_VIMGENCB_STR-TUPMEMB sy-vline
WA_VIMGENCB_STR-FFUNC sy-vline
WA_VIMGENCB_STR-PFUNC sy-vline
WA_VIMGENCB_STR-UFMEMB sy-vline
WA_VIMGENCB_STR-UPMEMB sy-vline
WA_VIMGENCB_STR-DYNP1 sy-vline
WA_VIMGENCB_STR-DYNP2 sy-vline
WA_VIMGENCB_STR-TVDIR sy-vline
WA_VIMGENCB_STR-REGCUA sy-vline
WA_VIMGENCB_STR-REGTEXT sy-vline
WA_VIMGENCB_STR-REGPROG sy-vline
WA_VIMGENCB_STR-REGTOP sy-vline
WA_VIMGENCB_STR-REGDYNP1 sy-vline
WA_VIMGENCB_STR-CORRNO sy-vline
WA_VIMGENCB_STR-DELPOOL sy-vline
WA_VIMGENCB_STR-DELVARI sy-vline
WA_VIMGENCB_STR-DELEVENTS sy-vline
WA_VIMGENCB_STR-DELAUTGRP sy-vline
WA_VIMGENCB_STR-RC_POOL sy-vline
WA_VIMGENCB_STR-RC_PROG sy-vline
WA_VIMGENCB_STR-RC_TOP sy-vline
WA_VIMGENCB_STR-RC_IMEMB sy-vline
WA_VIMGENCB_STR-RC_TMEMB sy-vline
WA_VIMGENCB_STR-RC_FMEMB sy-vline
WA_VIMGENCB_STR-RC_TFFUNC sy-vline
WA_VIMGENCB_STR-RC_TPFUNC sy-vline
WA_VIMGENCB_STR-RC_TUFMEMB sy-vline
WA_VIMGENCB_STR-RC_TUPMEMB sy-vline
WA_VIMGENCB_STR-RC_FFUNC sy-vline
WA_VIMGENCB_STR-RC_PFUNC sy-vline
WA_VIMGENCB_STR-RC_UFMEMB sy-vline
WA_VIMGENCB_STR-RC_UPMEMB sy-vline
WA_VIMGENCB_STR-RC_DYNP1 sy-vline
WA_VIMGENCB_STR-RC_DYNP2 sy-vline
WA_VIMGENCB_STR-RC_TVDIR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.