ABAP Select data from SAP table VILMPE_TAB into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP VILMPE_TAB table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VILMPE_TAB. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the VILMPE_TAB table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_VILMPE_TAB TYPE STANDARD TABLE OF VILMPE_TAB,
      WA_VILMPE_TAB TYPE VILMPE_TAB,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <VILMPE_TAB> TYPE VILMPE_TAB.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_VILMPE_TAB.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM VILMPE_TAB
  INTO TABLE IT_VILMPE_TAB.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM VILMPE_TAB
*  INTO TABLE @DATA(IT_VILMPE_TAB2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_VILMPE_TAB INDEX 1 INTO DATA(WA_VILMPE_TAB2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_VILMPE_TAB ASSIGNING <VILMPE_TAB>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<VILMPE_TAB>-OBJNR = 1.
<VILMPE_TAB>-CREATIONTYPE = 1.
<VILMPE_TAB>-RERF = 1.
<VILMPE_TAB>-DERF = 1.
<VILMPE_TAB>-TERF = 1.
ENDLOOP.

LOOP AT IT_VILMPE_TAB INTO WA_VILMPE_TAB.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_VILMPE_TAB-REHER, sy-vline,
WA_VILMPE_TAB-RBEAR, sy-vline,
WA_VILMPE_TAB-DBEAR, sy-vline,
WA_VILMPE_TAB-TBEAR, sy-vline,
WA_VILMPE_TAB-RBHER, sy-vline,
WA_VILMPE_TAB-RESPONSIBLE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_VILMPE_TAB you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VILMPE_TAB TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VILMPE_TAB INTO WA_VILMPE_TAB. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit REDAT, internal->external for field VALIDTO CALL FUNCTION 'CONVERSION_EXIT_REDAT_OUTPUT' EXPORTING input = WA_VILMPE_TAB-VALIDTO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VILMPE_TAB-VALIDTO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit REDAT, internal->external for field PEREVOCDATE CALL FUNCTION 'CONVERSION_EXIT_REDAT_OUTPUT' EXPORTING input = WA_VILMPE_TAB-PEREVOCDATE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VILMPE_TAB-PEREVOCDATE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VILMPE_TAB_STR,
OBJNR TYPE STRING,
CREATIONTYPE TYPE STRING,
RERF TYPE STRING,
DERF TYPE STRING,
TERF TYPE STRING,
REHER TYPE STRING,
RBEAR TYPE STRING,
DBEAR TYPE STRING,
TBEAR TYPE STRING,
RBHER TYPE STRING,
RESPONSIBLE TYPE STRING,
USEREXCLUSIVE TYPE STRING,
AUTHGRP TYPE STRING,
PETYPE TYPE STRING,
XPE TYPE STRING,
VALIDFROM TYPE STRING,
VALIDTO TYPE STRING,
LOCHIER TYPE STRING,
PEERPAGENO TYPE STRING,
PECSNO TYPE STRING,
PEPSNO TYPE STRING,
PEDPNO TYPE STRING,
PEPREDPNO TYPE STRING,
PEPSTYPE TYPE STRING,
RGRNART TYPE STRING,
PEPLANDATE TYPE STRING,
PEEFFECTDATE TYPE STRING,
PECHANGEDATE TYPE STRING,
PESTATEMENTDATE TYPE STRING,
PELASTMODDATE TYPE STRING,
PEREVOCDATE TYPE STRING,END OF T_EKKO_STR. DATA: WA_VILMPE_TAB_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VILMPE_TAB_STR-OBJNR sy-vline
WA_VILMPE_TAB_STR-CREATIONTYPE sy-vline
WA_VILMPE_TAB_STR-RERF sy-vline
WA_VILMPE_TAB_STR-DERF sy-vline
WA_VILMPE_TAB_STR-TERF sy-vline
WA_VILMPE_TAB_STR-REHER sy-vline
WA_VILMPE_TAB_STR-RBEAR sy-vline
WA_VILMPE_TAB_STR-DBEAR sy-vline
WA_VILMPE_TAB_STR-TBEAR sy-vline
WA_VILMPE_TAB_STR-RBHER sy-vline
WA_VILMPE_TAB_STR-RESPONSIBLE sy-vline
WA_VILMPE_TAB_STR-USEREXCLUSIVE sy-vline
WA_VILMPE_TAB_STR-AUTHGRP sy-vline
WA_VILMPE_TAB_STR-PETYPE sy-vline
WA_VILMPE_TAB_STR-XPE sy-vline
WA_VILMPE_TAB_STR-VALIDFROM sy-vline
WA_VILMPE_TAB_STR-VALIDTO sy-vline
WA_VILMPE_TAB_STR-LOCHIER sy-vline
WA_VILMPE_TAB_STR-PEERPAGENO sy-vline
WA_VILMPE_TAB_STR-PECSNO sy-vline
WA_VILMPE_TAB_STR-PEPSNO sy-vline
WA_VILMPE_TAB_STR-PEDPNO sy-vline
WA_VILMPE_TAB_STR-PEPREDPNO sy-vline
WA_VILMPE_TAB_STR-PEPSTYPE sy-vline
WA_VILMPE_TAB_STR-RGRNART sy-vline
WA_VILMPE_TAB_STR-PEPLANDATE sy-vline
WA_VILMPE_TAB_STR-PEEFFECTDATE sy-vline
WA_VILMPE_TAB_STR-PECHANGEDATE sy-vline
WA_VILMPE_TAB_STR-PESTATEMENTDATE sy-vline
WA_VILMPE_TAB_STR-PELASTMODDATE sy-vline
WA_VILMPE_TAB_STR-PEREVOCDATE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.