ABAP Select data from SAP table VIITTC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP VIITTC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to VIITTC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the VIITTC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_VIITTC TYPE STANDARD TABLE OF VIITTC,
      WA_VIITTC TYPE VIITTC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <VIITTC> TYPE VIITTC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_VIITTC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM VIITTC
  INTO TABLE IT_VIITTC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM VIITTC
*  INTO TABLE @DATA(IT_VIITTC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_VIITTC INDEX 1 INTO DATA(WA_VIITTC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_VIITTC ASSIGNING <VIITTC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<VIITTC>-MANDT = 1.
<VIITTC>-INTRENO = 1.
<VIITTC>-BUKRS = 1.
<VIITTC>-TCNO = 1.
<VIITTC>-OBJNR = 1.
ENDLOOP.

LOOP AT IT_VIITTC INTO WA_VIITTC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_VIITTC-RERF, sy-vline,
WA_VIITTC-DERF, sy-vline,
WA_VIITTC-TERF, sy-vline,
WA_VIITTC-REHER, sy-vline,
WA_VIITTC-RBEAR, sy-vline,
WA_VIITTC-DBEAR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_VIITTC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_VIITTC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_VIITTC INTO WA_VIITTC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field TCNO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VIITTC-TCNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIITTC-TCNO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TCTYPE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_VIITTC-TCTYPE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIITTC-TCTYPE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit REDAT, internal->external for field CORRDATETO CALL FUNCTION 'CONVERSION_EXIT_REDAT_OUTPUT' EXPORTING input = WA_VIITTC-CORRDATETO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIITTC-CORRDATETO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit REDAT, internal->external for field SERVICEDATETO CALL FUNCTION 'CONVERSION_EXIT_REDAT_OUTPUT' EXPORTING input = WA_VIITTC-SERVICEDATETO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_VIITTC-SERVICEDATETO.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_VIITTC_STR,
MANDT TYPE STRING,
INTRENO TYPE STRING,
BUKRS TYPE STRING,
TCNO TYPE STRING,
OBJNR TYPE STRING,
RERF TYPE STRING,
DERF TYPE STRING,
TERF TYPE STRING,
REHER TYPE STRING,
RBEAR TYPE STRING,
DBEAR TYPE STRING,
TBEAR TYPE STRING,
RBHER TYPE STRING,
RESPONSIBLE TYPE STRING,
USEREXCLUSIVE TYPE STRING,
AUTHGRP TYPE STRING,
TCTYPE TYPE STRING,
XTC TYPE STRING,
CORRDATEFROM TYPE STRING,
CORRDATETO TYPE STRING,
FIRSTUSEDATE TYPE STRING,
SERVICEDATEFROM TYPE STRING,
SERVICEDATETO TYPE STRING,
TCSTATUS TYPE STRING,
CURRENCY TYPE STRING,
FIRSTCALCDATE TYPE STRING,
ADDTEXT TYPE STRING,
BASELOCK TYPE STRING,END OF T_EKKO_STR. DATA: WA_VIITTC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_VIITTC_STR-MANDT sy-vline
WA_VIITTC_STR-INTRENO sy-vline
WA_VIITTC_STR-BUKRS sy-vline
WA_VIITTC_STR-TCNO sy-vline
WA_VIITTC_STR-OBJNR sy-vline
WA_VIITTC_STR-RERF sy-vline
WA_VIITTC_STR-DERF sy-vline
WA_VIITTC_STR-TERF sy-vline
WA_VIITTC_STR-REHER sy-vline
WA_VIITTC_STR-RBEAR sy-vline
WA_VIITTC_STR-DBEAR sy-vline
WA_VIITTC_STR-TBEAR sy-vline
WA_VIITTC_STR-RBHER sy-vline
WA_VIITTC_STR-RESPONSIBLE sy-vline
WA_VIITTC_STR-USEREXCLUSIVE sy-vline
WA_VIITTC_STR-AUTHGRP sy-vline
WA_VIITTC_STR-TCTYPE sy-vline
WA_VIITTC_STR-XTC sy-vline
WA_VIITTC_STR-CORRDATEFROM sy-vline
WA_VIITTC_STR-CORRDATETO sy-vline
WA_VIITTC_STR-FIRSTUSEDATE sy-vline
WA_VIITTC_STR-SERVICEDATEFROM sy-vline
WA_VIITTC_STR-SERVICEDATETO sy-vline
WA_VIITTC_STR-TCSTATUS sy-vline
WA_VIITTC_STR-CURRENCY sy-vline
WA_VIITTC_STR-FIRSTCALCDATE sy-vline
WA_VIITTC_STR-ADDTEXT sy-vline
WA_VIITTC_STR-BASELOCK sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.